Kia Carens. Instruction — part 325
Heating,Ventilation, Air Conditioning
Blower - Blower Unit
Heating,Ventilation, Air Conditioning
2001 > 1.8L DOHC >
REMOVAL
BLOWER/EVAPORATOR
1. Discharge refrigerant from A/C system.(Refer to operating instructions of your refrigerant recovery/recycling
/charging stationfor proper procedures.
2. Disconnect inlet and outlet pipe from evaporator.
Immediately plug all open fittings to keep moisture out of system.
3. Remove cover and drain hose.
4. Remove instrument panel and disconnect wiring harness connector.
5. Remove blower unit.
INSTALLATION
1. Install in reverse order of removal.
2. Evacuate refrigerant system.Refer to operating instructionsof your refrigerant recovery/recycling/ charging
station for proper procedures.
3. Charge A/C system. Refer to operating instructionsof your refrigerant recovery/recycling/charging station for
proper procedures.
Heating,Ventilation, Air Conditioning
Blower - Blower Motor
Heating,Ventilation, Air Conditioning
2001 > 1.8L DOHC >
INSPECTION
1. Disconnect blower motor connectors.
2. Verify that blower motor runs when connecting 12V to terminal B (R)and grounding terminal A (R/L).
3. If not as specified, replace blower motor.