Kia Carnival (2009+). Instruction — part 569

13

Hi - Scan





14

Hazard Select

15

Incar Motor (-)

16

GND

2009 > G 2.7 DOHC >

REPLACEMENT

1. Disconnect the negative (-) battery terminal.

2. Remove the center air vent. (Refer to BD group)

3. Remove the heater & A/C controller (A) after loosening 4 screws.

4. Remove the heater & A/C controller (A).

5. Installation is the reverse order of removal.

2009 > G 2.7 DOHC >

SELFDIAGNOSIS

1. Self-diagnosis process

2. How to read self-diagnostic code

After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup
temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format
Fault code

Display

Fail description

00

NORMAL

11

IN CAR SENSOR OPEN (HIGH)

12

IN CAR SENSOR SHORT (LOW)

13

AMBIENT SENSOR OPEN (HIGH)

14

AMBIENT SENSOR SHORT (LOW)

15

WATER TEMP SENSOR OPEN (HIGH)

16

WATER TEMP SENSOR SHORT (LOW)

17

EVAP SENSOR OPEN (HIGH)

18

EVAP SENSOR SHORT (LOW)

19

TEMP DOOR POTENTIOMETER OPEN/SHORT (DR)

20

TEMP DOOR POTENTIOMETER FAULT

21

MODE DOOR POTENTIOMETER OPEN/SHORT (DR)

22

MODE DOOR POTENTIOMETER FAULT

23

HUMIDITY SENSOR OPEN (HIGH)

24

HUMIDITY SENSOR SHORT (LOW)

25

INTAKE DOOR POTENTIOMETER OPEN/SHORT

26

INTAKE DOOR POTENTIOMETER FAULT

32

TEMP DOOR POTENTIOMETER OPEN/SHORT (PA)

33

TEMP DOOR POTENTIOMETER FAULT (PA)

34

MODE DOOR POTENTIOMETER OPEN/SHORT (PA)

35

MODE DOOR POTENTIOMETER FAULT (PA)

36

TEMP DOOR POTENTIOMETER OPEN/SHORT (REAR)

37

TEMP DOOR POTENTIOMETER FAULT (REAR)

38

MODE DOOR POTENTIOMETER OPEN/SHORT (REAR)

39

MODE DOOR POTENTIOMETER FAULT (REAR)

3. Fault code display

(1) Continuance operation : DTC code is one.

(2) Continuance operation : DTC code is more two.

(3) STEP operation

A. Nomal or one fault code is same as a continuance operation.
B. DTC code os more two.

4. Diagnostic procedure refer to DTC code.

5. Fail safe

(1) In-car temperature sensor: Control with the value of 25°C(77°F)

(2) Ambient temperature sensor: Control with the value of 20°C(67°F)

(3) Evaporator temperature sensor: Control with the value of -2°C(28.4°F)

(4) Humidity sensor: Control with the value of 10%

(5) Temperature sensor : Control with the value of -2°C (28.4°F)

(6) Temperature control actuator (Air mix potentiometer):

If temperature setting 17°C-24.5°C, fix at maximum cooling position.
If temperature setting 25°C-32°C, fix at maximum heating position.