Kia Sedona (2008 year). Instruction — part 234
DTC DETECTING CONDITION CHART
SPECIFICATION
Refer to DTC B1233.
MONITOR SCAN TOOL DATA
1. Connect scan tool to data link connector (DLC).
2. Engine "ON"
3. Monitor the "IN-CAR TEMP. SENSOR" Parameter on the scan tool.
Fig. 65: Diagnosis Function Screen Display - In-Car Temp Sensor
Courtesy of KIA MOTORS AMERICA, INC.
4. Are the DTC B1234 present and is parameter of "IN-CAR TEMP. SENSOR" fixed?
Parameter of "IN-CAR TEMP. SENSOR" will be fixed at 25°C (77°F), if there is any fault in IN-CAR
TEMP. SENSOR.
YES
Go to TERMINAL AND CONNECTOR INSPECTION procedure.
Item
Detecting Condition
Possible cause
DTC Strategy
Resistance check
Open Circuit in harness
Faulty in-car temp. Sensor
Faulty A/C control unit
Threshold value
> 509.57 kohms
Detecting time
0.3 sec
FAIL SAFE
Control with the value of 25°C (77°F)
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:07 PM
Page 58
© 2006 Mitchell Repair Information Company, LLC.
NO
Fault is intermittent caused by poor contact in the sensor's and/or A/C controller's connector or was
repaired and A/C controller memory was not cleared. Thoroughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary
and then go to "VERIFICATION OF VEHICLE REPAIR" procedure.
TERMINAL AND CONNECTOR INSPECTION
Refer to DTC B1233.
SIGNAL CIRCUIT INSPECTION
1. Check for open in harness.
1. Ignition "OFF"
2. Disconnect in-car temp, sensor.
3. Measure resistance between terminal "4" of in-car temp, sensor and terminal "3" of A/C Control
Unit.
Specification: Approx. 0 ohms
Fig. 66: Checking Resistance Between Terminal "4" Of In-Car Temp, Sensor And Terminal
"3" Of A/C Control Unit
Courtesy of KIA MOTORS AMERICA, INC.
4. Is the measured resistance within specifications?
YES
Go to "GROUND CIRCUIT INSPECTION" procedure.
NO
Check for open in harness. Repair as necessary and go to "VERIFICATION OF VEHICLE
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:07 PM
Page 59
© 2006 Mitchell Repair Information Company, LLC.
REPAIR" procedure.
GROUND CIRCUIT INSPECTION
1. Check for open in ground harness.
1. Ignition "OFF"
2. Disconnect in-car temp, sensor.
3. Measure resistance between terminal "2" of in-car temp, sensor and terminal "11" of A/C Control
Unit.
Specification: Approx. 0 ohms
Fig. 67: Checking Resistance Between Terminal "2" Of In-Car Temp, Sensor And Terminal
"11" Of A/C Control Unit
Courtesy of KIA MOTORS AMERICA, INC.
4. Is the measured resistance within specifications?
YES
Go to "COMPONENT INSPECTION" procedure.
NO
Check for open in ground harness. Repair as necessary and go to "VERIFICATION OF
VEHICLE REPAIR" procedure.
COMPONENT INSPECTION
Refer to DTC B1233.
VERIFICATION OF VEHICLE REPAIR
Refer to DTC B1233.
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 60
© 2006 Mitchell Repair Information Company, LLC.
DTC B1237 AMBIENT TEMPERATURE SENSOR SHORT (LOW)
COMPONENT LOCATION
Fig. 68: Identifying Ambient Temperature Sensor Component Location
Courtesy of KIA MOTORS AMERICA, INC.
GENERAL DESCRIPTION
The ambient temperature senor located at the center stay of the condenser, detects ambient air temperature. It is
a negative type thermistor whose resistance is inversely proportional to temperature. Its output is used for
discharge temperature sensor, sensor fail-safe, temperature regulation door lock, blower motor level control,
mix mode control and in-car humidity control.
DTC DESCRIPTION
The A/C controller sets DTC B1237 if there is a short circuit in ambient temp, sensor signal harness or the
measured resistance value of sensor is less than threshold value (about 7.48kohms)
DTC DETECTING CONDITION
DTC DETECTING CONDITION CHART
SPECIFICATION
TEMPERATURE SPECIFICATION
Item
Detecting Condition
Possible cause
DTC Strategy
Resistance check
Short circuit in harness
Faulty ambient temp. Sensor
Faulty A/C control unit
Threshold value
< 7.48 k ohms
Detecting time
0.3 sec
FAIL SAFE
Control with the value of 20°C (68°F)
Temperature [°C (°F)]
Resistance (kohms)
Temperature [°C (°F)]
Resistance (kohms)
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 61
© 2006 Mitchell Repair Information Company, LLC.