Kia Sedona (2008 year). Instruction — part 237
YES
Go to "GROUND CIRCUIT INSPECTION" procedure.
NO
Check for open in harness. Repair as necessary and go to "VERIFICATION OF VEHICLE
REPAIR" procedure.
GROUND CIRCUIT INSPECTION
1. Check for open in ground harness.
1. Ignition "OFF"
2. Disconnect ambient temp, sensor.
3. Measure resistance between terminal "2" of ambient temp, sensor and chassis ground.
Specification: Approx. 0 ohms
Fig. 77: Checking Resistance Between Terminal "2" Of Ambient Temp, Sensor And Chassis
Ground
Courtesy of KIA MOTORS AMERICA, INC.
4. Is the measured resistance within specifications?
YES
Go to "COMPONENT INSPECTION" procedure.
NO
Check for open in ground harness. Repair as necessary and go to "VERIFICATION OF
VEHICLE REPAIR" procedure.
COMPONENT INSPECTION
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 70
© 2006 Mitchell Repair Information Company, LLC.
Refer to DTC B1237.
VERIFICATION OF VEHICLE REPAIR
Refer to DTC B1237.
DTC B1241 EVAPORATOR TEMPERATURE SENSOR SHORT (LOW)
COMPONENT LOCATION
Fig. 78: Identifying Evaporator Temperature Sensor Component Location
Courtesy of KIA MOTORS AMERICA, INC.
GENERAL DESCRIPTION
The Evaporator temperature sensor located on heater unit, detects the core temperature and interrupts
compressor relay power, in order to prevent evaporator freezing by excessive cooling. It is a negative type
thermistor whose resistance is inversely proportional to temperature.
DTC DESCRIPTION
The A/C controller sets DTC B1241 if there is a short circuit in evaporator temp, sensor signal harness or the
measured resistance value of sensor is less than threshold value (about 0.9kohms)
DTC DETECTING CONDITION
DTC DETECTING CONDITION CHART
Item
Detecting Condition
Possible cause
DTC Strategy
Resistance check
Short circuit in harness
Faulty Evaporator temp. Sensor
Faulty A/C control unit
Threshold value
< 0.9kohms
Detecting time
0.3 sec
FAIL SAFE
Control with the value of -2°C(28.4°F)
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 71
© 2006 Mitchell Repair Information Company, LLC.
SPECIFICATION
Resistance value of evaporator sensor as a function of temperature.
TEMPERATURE SPECIFICATION
MONITOR SCAN TOOL DATA
1. Connect scan tool to Data Link Connector (DLC).
2. Engine "ON"
3. Monitor the "EVAPORATIVE SENSOR" Parameter on the scan tool.
Fig. 79: Diagnosis Function Screen Display - Evaporative Sensor
Courtesy of KIA MOTORS AMERICA, INC.
4. Are the DTC B1241 present and is parameter of "EVAPORATIVE SENSOR" fixed?
Parameter of "EVAPORATIVE SENSOR" will be fixed at -2°C (28.4°F), if there is any fault in
EVAPORATIVE SENSOR.
YES
Go to TERMINAL AND CONNECTOR INSPECTION procedure.
NO
Temperature [°C (°F)]
Resistance (kohms)
Temperature [°C (°F)]
Resistance (kohms)
-10 (14)
13.6
15 (59)
3.9
0 (32)
8
30 (86)
2
5 (41)
6.2
40 (104)
1.3
10 (50)
4.9
50 (122)
0.9
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 72
© 2006 Mitchell Repair Information Company, LLC.
Fault is intermittent caused by poor contact in the sensor's and/or A/C controller's connector or was
repaired and A/C controller memory was not cleared. Thoroughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary
and then go to "VERIFICATION OF VEHICLE REPAIR" procedure.
TERMINAL AND CONNECTOR INSPECTION
1. Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical
damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination,
deterioration, or damage.
3. Has a problem been found?
YES
Repair as necessary and go to "VERIFICATION OF VEHICLE REPAIR" procedure.
NO
Go to "SIGNAL CIRCUIT INSPECTION" procedure.
SIGNAL CIRCUIT INSPECTION
1. Check for short to ground in harness.
1. Ignition "OFF"
2. Disconnect evaporator temp, sensor.
3. Measure resistance between terminal "1" of evaporator temp, sensor and chassis ground.
Specification: Approx. infinity ohms
Fig. 80: Checking Resistance Between Terminal "1" Of Evaporator Temp, Sensor And
2008 Kia Sedona EX
2008 HVAC Blower & A/C Controls (Automatic) - Sedona
Microsoft
Monday, May 24, 2010 3:56:08 PM
Page 73
© 2006 Mitchell Repair Information Company, LLC.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст