Kia Carnival (2007 year). Instruction — part 99

Solenoid Valve

2007 > 2.7L V6 GASOLINE >

DESCRIPTION

Actuators

Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C~130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5

Ω (LR, 2ND, UD, OD, TCC)

4.35 ± 0.5

Ω (VFS)

- Surge voltage: 56 V (Except VFS)

(LR, 2ND, UD, OD, DCC)

Location

Solenoid Valves Schedule

Position

Solenoid valves

Operation

LR

2ND

UD

OD

* DCC

1st gear

OFF

ON

OFF

ON

OFF

2nd gear

ON

OFF

OFF

ON

OFF

3rd gear

ON

ON

OFF

OFF

ON

4th gear

ON

OFF

ON

OFF

ON

Reverse

OFF

ON

ON

ON

OFF

N, P (STD. mode)

OFF

ON

ON

ON

OFF

N, P (Hold mode)

ON

OFF

ON

ON

OFF

*: Reference value.
(DCC solenoid valve will be ON when the operating condition is satisfied)

2007 > 2.7L V6 GASOLINE >

INSPECTION

1. If the value is out of specification according to the chart below, remove the valve body cover.

2. Measure the resistance again after disconnecting solenoid valve connector.

Specification (20°C):
2.5 ~ 3.5

Ω (LR, 2ND, UD, OD, TCC)

3. If the value is out of specification replace the solenoid valve.

Pin No.

Name

Resistance

6&9

DCC (TCC)

2.5~3.5

Ω (20°C)

6&11

LR

4&5

2ND

3&5

UD

5&12

OD

Была ли эта страница вам полезна?