Isuzu Amigo / Axiom / Trooper / Rodeo / VehiCross. Service manual — part 255
6E–50
6VE1 3.5L ENGINE DRIVEABILITY AND EMISSIONS
10. Push “Reset” soft key.
060RY00098
11. Select F2: O2-Loop status.
060R200071
12. This test is check the “Closed Loop Status”
performance.
13. Push “Open Loop” or “Closed Loop” soft key.
060RY00099
14. Control O2-Loop and check data list.
15. If data list changes, the O2-Loop is normal.
Instruments Test
This test is conducted check Instruments for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Ignition SW is “On”.
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078
6E–51
6VE1 3.5L ENGINE DRIVEABILITY AND EMISSIONS
4. Select F4: Instruments in the Miscellaneous Menu.
060RY00106
5. Select F0: Fuel Gauge level.
060RY00107
6. Push “Decrease” or “Increase” soft key.
060RY00100
7. Control Fuel Level and check data list.
8. If data list and Fuel gauge meter changes, Fuel
Gauge level is normal.
9. Select F1: Tachometer Control Test.
060RY00107
6E–52
6VE1 3.5L ENGINE DRIVEABILITY AND EMISSIONS
10. Push “Inactive” or “active” soft key.
060RY00101
11. Control tachometer and data list.
12. If data list and meter changes, the tachometer control
is normal.
EGR Control Test
This test is conducted check EGR valve for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Run the Engine at idle.
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078
4. Select F5: EGR Control Test in the Miscellaneous
Test.
060RY00084
5. Control EGR Valve and check data list.
060RY00103
6. If data list changes, the EGR Control is normal.
Variable Intake Manifold Solenoid Test
This test is conducted check VIM Solenoid for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
6E–53
6VE1 3.5L ENGINE DRIVEABILITY AND EMISSIONS
2. Ignition SW is “On”.
060RY00104
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078
4. Select F6: Variable Intake Manifold Solenoid Test.
060RY00085
5. Push “On” or “Off” soft key.
060RX028
6. Control VIM Solenoid check data list.
7. If data list changes, the VIM Solenoid is normal.