Isuzu N-Series. Service manual — part 296
HSA (HILL START AID) 5A5-63
Neutral Switch
Removal
1. Remove the neutral switch.
• Disconnect the connector.
• Twist off the switch to remove.
Legend
1. Neutral switch
2. Connector (gray)
Inspection
Press the switch to check the continuity between the
connector terminals.
With switch released = Continuity exists
With switch pressed = No continuity
Installation
1. Apply liquid gasket to the threaded portion of the
neutral switch to install.
Liquid gasket: THREE BOND 1141
Tighten:
Neutral switch to 34 N
⋅m (3.5 kg⋅m/25.1 lb⋅ft)
N5A3055E
N5A3056E
5A5-64 HSA (HILL START AID)
Stop Lamp Switch
Removal
1. Remove the stop lamp switch.
• Disconnect the connector of the stop lamp
switch.
• Loosen the lock nut.
• Turn the switch body to remove from the brack-
et.
Legend
1. Lock nut
2. Brake pedal
3. Stop lamp switch
Installation
1. Install the stop lamp switch.
• Screw in until the thread end of the stop lamp
switch contacts the brake pedal.
Legend
1. Brake pedal
2. Stop lamp switch
3. Lock nut
Caution:
Screw in until the thread end of the stop lamp switch
contacts the brake pedal.
• After contacting with the pedal, back off the
switch to make clearance between 0.5 — 1.0
mm (0.02 — 0.04 in), and then tighten the lock
nut.
N5A3057E
N5A3058E
HSA (HILL START AID) 5A5-65
Clutch Fluid Pressure Switch
Removal
1. Check the clutch fluid pressure switch.
• Disconnect the clutch fluid pressure switch con-
nector, and check for continuity between the
connector terminals with the clutch pedal fully
depressed/released.
With clutch pedal depressed = Continuity exists
With clutch pedal released = No continuity
2. Remove the clutch fluid pressure switch.
• Disconnect the connector, and twist off the
hexagon nut portion of the switch.
Legend
1. Clutch fluid pressure switch
2. Clutch booster
Installation
1. Install the clutch fluid pressure switch.
Tighten:
Clutch fluid pressure switch to 15 N
⋅m (1.5 kg⋅m/11.1
lb
⋅ft)
N5A3059E
N5A3060E
5A5-66 HSA (HILL START AID)
Diode Box
Removal
1. Remove the instrument panel.
2. Disconnect the connector.
3. Remove the diode box.
Legend
1. Diode box
2. Connector
3. Relay box
Inspection
Check for continuity between the unit terminals.
Installation
Install in the reverse order of removal.
N5A3061E
N5A3062E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.