Mercedes-Benz Sprinter / Dodge Sprinter. Service manual — part 51
Symptom:
RKE INTERFACE CIRCUIT SHORT TO GROUND - CTM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO GROUND - CTM
When Monitored:
Whenever the battery voltage is above 10.0 volts and the module is
connected.
Set Condition:
If the CTM monitors a resistance below 7500.0 ohms for over 1 minute,
this code will set.
POSSIBLE CAUSES
DTC PRESENT
CENTRAL TIMER MODULE SHORTED
RKE INTERFACE WIRE SHORTED
SKREEM SHORTED
TEST
ACTION
APPLICABILITY
1
With the DRBIII
t, record and erase DTC’s.
Cycle the ignition switch from ON to OFF to ON.
With the DRBIII
t, read DTC’s.
Using the RKE transmitter, operate the Door Locks several times while observing the
DRBIII
t.
Wait 10 seconds.
Does the DRBIII
t display RKE INTERFACE CIRCUIT SHORT TO GROUND?
All
Yes
→ Go To 2
No
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Using the
RKE transmitter, operate the door locks several times and re-
check for any DTC’s.
Perform BODY VERIFICATION TEST - VER 1.
2
Turn the ignition off.
Disconnect the Central Timer Module C1 connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance below 8500.0 ohms?
All
Yes
→ Go To 3
No
→ Replace the Central Timer Module.
Perform BODY VERIFICATION TEST - VER 1.
201
POWER DOOR LOCKS/RKE
TEST
ACTION
APPLICABILITY
3
Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance below 20000.0 ohms?
All
Yes
→ Repair the RKE Interface circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Replace the Sentry Key RemotE Entry Module.
Perform BODY VERIFICATION TEST - VER 1.
202
POWER DOOR LOCKS/RKE
RKE INTERFACE CIRCUIT SHORT TO GROUND - CTM —
Continued
Symptom:
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM
When Monitored:
Whenever the battery voltage is above 10.0 volts and the module is
connected.
Set Condition:
If the SKREEM monitors a resistance below 4000.0 ohms or over 9000.0
ohms for over 30 seconds, this code will set.
POSSIBLE CAUSES
DTC PRESENT
SENTRY KEY REMOTE ENTRY MODULE SHORTED
RKE INTERFACE WIRE SHORTED
RKE INTERFACE WIRE OPEN
CENTRAL TIMER MODULE FAILURE
TEST
ACTION
APPLICABILITY
1
With the DRBIII
t, record and erase DTC’s.
Cycle the ignition switch from ON to OFF to ON.
With the DRBIII
t, read DTC’s.
Using the RKE transmitter, operate the Door Locks several times while observing the
DRBIII
t.
Wait 10 seconds.
Does the DRBIII
t display RKE INTERFACE CIRCUIT OPEN OR SHORT TO
GROUND?
All
Yes
→ Go To 2
No
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Using the
RKE transmitter, operate the door locks several times and re-
check for any DTC’s.
Perform BODY VERIFICATION TEST - VER 1.
2
Turn the ignition off.
Disconnect the Sentry Key RemotE Entry Module connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance between 5500.0 (5.5K) and 6500.0 (6.5K) ohms?
All
Yes
→ Replace the Sentry Key Remote Entry Module.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 3
203
POWER DOOR LOCKS/RKE
TEST
ACTION
APPLICABILITY
3
Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance below 20000.0 ohms?
All
Yes
→ Repair the RKE Interface circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 4
4
Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Measure the resistance of the RKE Interface circuit between the SKREEM connector
and the CTM C1 connector..
Is the resistance below 5.0 ohms?
All
Yes
→ Replace the Central Timer Module.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Repair the RKE Interface circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
204
POWER DOOR LOCKS/RKE
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM —