Opel Frontera UBS. Service manual — part 12
00 – 20 SERVICE INFORMATION
CERAMIC HEATER
When the fan control knob (fan switch) turns on
with the temperature control knob set to “FULL
HOT” (full hot switch “ON”), the ceramic heater in
the heater unit turns on and the blow temperature
goes up. When the ceramic heater turns on, FICD
starts to operate at the same time. When either one
of the fan switch, the full hot switch or the thermo
switch (which turns on when the coolant tempera-
ture gets below 80
°
C (176
°
F) turns off, the ceramic
heater also turns off.
FL-3
40A
C/HEATER
RELAY;
HEATER A/C
ECM
(J1-23)
2
4
1
3
C-20
10A
A/C
FL-1
80A
MAIN
B-18
B-1
B-36
1
3
X-12
2
4
1
3
X-21
2
4
1
2
1
2
4
1
3
2
4
1
1
2
CERAMIC
HEATER
FAN SW.
B-19
B-48
I-18
B-44
B-49
RELAY;
THERMO
SW
RELAY;
CERAMIC
HEATER
DIODE
FULL HOT
SW.
B-1
B-48
1
2
1
2
2 1
1 2
B-49
I-18
2
1
3
5
4
6
1
2
3
4
B-36
X-12
X-21
1
2
3
4
B-44
(RHD)
B-2
(LHD)
B-2
D08RWD66
SERVICE INFORMATION 00 – 21
CERAMIC HEATER DOES NOT OPERATE
•
ARE NO. FL-3 (40A) AND NO. C-20 (10A) OK?
YES
NO
REPLACE
REPLACE
REPLACE
REPLACE
•
ARE A/C AND CERAMIC HEATER RELAYS OK?
YES
NO
•
ARE BLOWER MOTOR AND FAN SW. OK?
YES
NO
•
IS FULL HOT SW. OK?
•
DOES TEMP. CONTROL LINK (HEATER UNIT)
OPERATE CORRECTLY?
YES
NO
REPLACE
•
TURN THE IGNITION SW. “ON” (ENGINE IS RUNNING)
•
CERAMIC HEATER “ON”
•
CHECK TO SEE IF BATTERY VOLTAGE IS PRESENT AT
CHASSIS SIDE CONNECTOR TERMINAL NO. B48-1
YES
NO
OPEN CIRCUIT
•
CHECK TO SEE IF BATTERY VOLTAGE IS PRESENT AT
CHASSIS SIDE CONNECTOR TERMINAL NO. B48-2
YES
NO
CERAMIC HEATER DEFECTIVE
•
CHECK THE CERAMIC HEATER OR CERAMIC HEATER-
RELATED HARNESS FOR A POOR GROUND AND REPAIR
IT AS NECESSARY
YES
NO
•
DOES CONTROL LEVER CABLE OPERATE CORRECTLY?
•
IS THERMO RELAY OK?
YES
NO
NO
YES
ADJUST OR REPLACE
REPAIR OR REPLACE
TEMP. CONTROL UNIT
00 – 22 SERVICE INFORMATION
CERAMIC HEATER DOES NOT STOP
WHEN THE IGNITION SW. “OFF”, DOES CERAMIC HEATER
STOP?
YES
NO
CERAMIC HEATER RELAY DEFECTIVE
•
SHORT CIRCUIT BETWEEN CHASSIS SIDE RELAY TERMINAL
NO. X12-3 AND CHASSIS SIDE CONNECTOR TERMINAL
NO. B49-1
SERVICE INFORMATION 00 – 23
AIR CONDITIONING CYCLE TROUBLESHOOTING
No cooling or insuffi-
cient cooling
Insufficient velocity
of cooling air
1. Magnetic clutch does not run
2. Compressor is not rotating properly
•
Drive belt loosened or broken
•
Magnetic clutch face is not
clean and slips
•
Incorrect clearance between
magnetic drive plate and pulley
•
Compressor oil leaks from shaft
seal or shell
•
Compressor seized
3. Insufficient or excessive charge of
refrigerant
4. Leaks in the refrigerant system
5. Condenser clogged or insufficient
radiation
6. Temperature control link unit of the
heater unit defective
7. Unsteady operation due to foreign
substance in expansion valve
8. Poor operation of electronic thermo-
stat
1. Evaporator clogged or frosted
2. Air leaking from cooling unit or air
duct
3. Blower motor does not rotate prop-
erly
•
Refer to “MAGNETIC CLUTCH”
troubleshooting
•
Adjust the drive belt to the specified
tension or replace the drive belt
•
Clean the magnetic clutch face or
replace
•
Adjust the clearance (Refer to
Section 1D “COMPRESSOR OVER-
HAUL”
•
Replace the compressor
•
Replace the compressor
•
Discharge and recover refrigerant.
Recharge to specified amount.
•
Check refrigerant system for leaks
and repair as necessary
Discharge and recover refrigerant.
Recharge to specified amount.
•
Clean the condenser or replace as
necessary
•
Check radiator or condenser fan
function
•
Repair the link unit
•
Replace the expansion valve
•
Check electronic thermostat and
replace as necessary
•
Check evaporator core and replace
or clean the core
•
Check evaporator and duct connec-
tion, then repair as necessary
•
Refer to Section 00 for “FAN
CONTROL KNOB (FAN SWITCH)”
troubleshooting
* For the execution of the charging and discharging operation in the table above, refer to the “RECOVERY,
RECYCLING, EVACUATING AND CHARGING” in section 1B.
TROUBLE
POSSIBLE CAUSE
CORRECTION