Opel Frontera UBS. Service manual — part 374
SERVICE INFORMATION 00 – 19
STARTER DOES NOT STOP THOUGH STARTER
SWITCH IS RETURNED TO “ON”
YES
NO
REPLACE STARTER SWITCH
MAGNETIC SWITCH CONTACTS
ARE FUSED AND NOT MOVED, OR
A RETURN SPRING IS BROKEN OR
DETERIORATED
DISCONNECTED STARTER SWITCH WIRING CONNECTOR, AND CHECK STARTER SWITCH OPERATION.
THERE MUST BE NO CONTINUITY EXCEPT ABOVE LINES
KEY
POSITION
BATTERY
B1
LOCK
OFF
ACC
ON
START
IGNITION
IG1
BATTERY
B2
ACCESSORIES
ACC
IGNITION
IG2
STARTER
ST
REPLACE MAGNETIC SWITCH
00 – 20 SERVICE INFORMATION
MAIN DATA AND SPECIFICATIONS
GENERAL SPECIFICATIONS
Engine type
Camshaft type
Cylinder line-type
Number of cylinders
Bore x stroke
Total piston displacement
Compression ratio
Engine weight (dry)
Engine idling speed (Reference)
Compression pressure
Firing order
Injection timing
VALVE SYSTEM
Intake valves
Exhaust valve
Valve clearance at
Oil filter
Oil capacity (Original factory fill or rebuilt engine)
Oil capacity (Service change)
with filter change
without filter change
Oil cooler
Inter cooler
Turbocharger
Control method
Lubrication method
Cooling method
(mm)
(cc)
(to 1)
N (kg/lb)
RPM
open at:
close at:
open at:
close at:
cold
intake:
exhaust:
mm (in)
Diesel, four cycle water cooled inline
Overhead valve
Dry type
4
95.4 x 107
3,059
20.0
2353 (240/529)(4JG2-NA)
2597 (265/584)(4JG2-T)
750 (4JG2-NA)
720 (4JG2-T)
2940 (30/426)-200
1–3–4–2
1
°
A.T.D.C (4JG2-NA)
T.D.C. (4JG2-T)
B.T.D.C. 24
°
A.B.D.C. 55
°
B.B.D.C. 54
°
A.T.D.C. 26
°
0.40 (0.016)
0.40 (0.016)
Full flow and bypass combined type
7.1 liters (6.3 US quarts)
6.0 liters (6.3 US quarts)
5.0 liters (5.3 US quarts)
Water cooled type
Air cooled type
Wastegate control
Pressurized control
Coolant cooled
kpa (kg/cm /psi)-rpm
2
SERVICE INFORMATION 00 – 21
Engine Cooling
Starting System
Cooling system
Radiator
Heat radiation capacity
Heat radiation area
Front area
Dry weight
Radiator cap
Valve opening pressure
Coolant capacity
Coolant forced circulation
(2 tube in row) Tube type corrugated
318 x 10 (76000)
15.63 (1.454)
0.309 (2.029)
83 (8.5/18.7 )
88.2~117.6 (0.899~1.199/12.78~17.05)
2.8 (2.46/2.96)
J/h (kcal/h)
m
2
(ft
2
)
m
2
(ft
2
)
N(Kg/lb)
kPa(Kg/cm
2
psi)
lit (Imp.qt./US qt.)
Coolant pump
Pulley ratio
Centrifugal impeller type
1.2
Coolant total capacity lit (Imp.qt./US qt.)
8.6 (7.57/9.09)
6
Rating
Voltage
Output
Time
Number of tooth of pinion
Rotating direction (as viewed from pinion)
Weight (approx.)
No-load characteristics
Voltage/current
Speed
Load characteristics
Voltage/current
Torque
Speed
Locking characteristics
Voltage/current
Torque
Model
HITACHI S14-03
V
kw
sec
12
30
9
Clockwise
N (kg/lb)
59 (6.0/13.2)
V/A
rpm
11/160 or less
3900 or more
V/A
N•m (kg•m/lb•ft)
rpm
10.85/300
7.4 (0.75/5.4) or more
2000 or more
V/A
N•m (kg•m/lb•ft)
3/1300 or less
26 (2.7/20) or more
11.5/120 or less
4000 or more
7.5/500
13 (1.3/9) or less
1400 or more
2/850 or less
16 (1.6/12) or more
2.2
2.8
DENSO ADR4G1
00 – 22 SERVICE INFORMATION
Charging System
Model (HITACHI)
Rated voltage
Rated output
LR150 – 446
12
50
LR180 – 501B
12
80
Rotating direction
(As viewed from pulled)
Pulley effective diameter
Weight (with pump)
Clockwise
Clockwise
80 (3.15)
65(6.6 /14.6)
80 (3.15)
76(7.8 /17.2)
V
A
mm(in)
N(Kg/lb)