Opel Frontera UBS. Service manual — part 2748
8D–192
WIRING SYSTEM
Circuit Diagram (LHD)-5
F
C
G
0.85
G/R
0.3
R/G
0.5
R/G
0.3
R/G
0.3
R/G
0.5
G/R
0.3
B
0.5
G/R
GLOVE
BOX
1
2
I-24
0.5
B
0.5
B
1.25
B
0.5
B
0.3
B
16
H-25
I-24
ASH TRAY
ILLUMINATION
CONTROLLER
2
1
I-19
I-19
1
I-7
3
H-26
2
I-7
B-19
BODY-LH
I-7
2
D08RW892
WIRING SYSTEM
8D–193
Parts Location (LHD)
Legend
(1) Rear Deffoger Switch
(2) Rear Wiper / Washer Switch
(3) Engin Warming Switch
(4) 4WD Switch
(5) Hazard Switch
(6) Meter
(7) Illumination Contoroller
(8) Head Light Wiper and Washer Switch
(9) Fog Light Switch
(10) I-5
(11) I-4
(12) I-7
(13) Instrument Harness
(14) I-9
(15) I-6
(16) I-11
(17) I-12
(18) I-25
(19) I-16
(20) I-17
(21) B-12
(22) H-32
(23) B-19
(24) H-25, H-26
(25) B-33
(26) B-30
(27) H-41, H-42
(28) Relay and Fuse Box (X-9)
(29) H-13, H-15, H-16
(30) I-24
(31) I-28
(32) I-20
23
22
27
26
25
21
28
30
31
32
5
6
14
13
7
12
10
8
9
18
17
20
15
16
4
3
24
11
29
19
1
2
D08RW893
8D–194
WIRING SYSTEM
Diagnosis
Interior Illumination Lights Inoperative
NO
YES
REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN 2 I-7 AND B-19
NO
YES
IS B-19 GROUNDED SECURELY?
•
•
IS THERE CONTINUITY BETWEEN 3 I-7 AND
THE GROUND?
YES
REPLACE THE ILLUMINATION CONTROLLER
GROUND IT SECURELY
REMOVE THE ILLUMINATION CONTROLLER
IS THERE CONTINUITY BETWEEN 2 I-7 AND
THE GROUND?
•
•
WITH THE LIGHTING SWITCH AT CLEARANCE LIGHT
POSITION, IS THE BATTERY VOLTAGE APPLIED BETWEEN
1 I-7 AND THE GROUND?
•
NO
YES
REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN 4 X-9 AND 1 I-7
NO
REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN TAIL RELAY AND 3 I-7
WIRING SYSTEM
8D–195
Turn Signal Light and Hazard Warning Light
General Description
The circuit consists of a turn signal switch
(combination switch), turn signal light, hazard
warning switch and flasher unit. When the turn
signal light switch is turned on with starter switch
on, turn signal light will operate. When turn signal
light is flashing, indicator light in meter also starts
flashing. When hazard warning switch is turned on,
current flows to flasher unit through hazard warning
switch to cause hazard warning light to flash
independent of position of starter switch. At the
same time, indicator lights in meter also start
flashing.