Opel Frontera UBS. Service manual — part 915
1B – 54 AIR CONDITIONING
E06RY00003
25(2.5/18)
25(2.5/18)
25(2.5/18)
25(2.5/18)
15(1.5/11)
15(1.5/11)
15(1.5/11)
15(1.5/11)
15(1.5/11)
TORQUE SPECIFICATIONS
N·m (kg·m/ib·ft)
AIR CONDITIONING 1B – 55
25 (2.5/18)
25 (2.5/18)
25 (2.5/18)
25 (2.5/18)
15 (1.5/11)
15 (1.5/11)
15 (1.5/11)
15 (1.5/11)
15 (1.5/11)
TORQUE SPECIFICATIONS (ROOF DUCT TYPE)
N·m (kg·m/ib·ft)
E06RY00002
1B – 56 AIR CONDITIONING
DIAGNOSIS
Rear Air Conditioning Cycle Diagnosis
Condition
Possible Cause
Correction
No cooling or insufficient cooling
Insufficient velocity of cooling air
Front air conditioner not switched
on.
Other
Clogged filter
Other
Switch front A/C switch ON.
See front air conditioner
workshop manual.
Clean or replace cooling unit filter.
See front air conditioner
workshop manual.
AIR CONDITIONING 1B – 57
FAN CONTROL SWITCH
Inspection
Using an electric circuit tester, check continuity between
terminals.
If not as specified, replace the switch.
1
2
3
4
OFF
LOW
MEDIUM
HIGH
Fan control switch
OFF
L
0.5 LG
0.85 Y
0.85 RG
0.85 B
M
H
1
2
3
4
Resistor
0.5
Ω
1.1
Ω
Mo
MH
ML
0.5 LG(ML)
0.85 WR(Mo)
0.85 RG(MH)
RESISTOR
Inspection
Using an electric circuit tester, check the resistance
between the terminals specified below.
If the resistances are not as specified, replace the resistor.
Terminal
Resistance (
Ω
)
Mo ~ MH
0.5
Mo ~ ML
1.6
825RY00058
826RY00016
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.