Opel Frontera UBS. Service manual — part 770



8D – 510 WIRING SYSTEM

4. Sliding Mechanism Does Not Operate

IS TILT & SLIDE SWITCH NORMAL?

YES

IS SLIDE MOTOR NORMAL?

REPAIR OR REPLACE THE TILT &
SLIDE SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN
OPEN CIRCUIT BETWEEN 5 T-1 AND 1 T-7 , 10 T-1 AND
2 T-7 OR 2 T-2

REPAIR OR REPLACE THE SLIDE
MOTOR

NO

5. Reclining Mechanism Does Not Operate

IS RECLINER SWITCH NORMAL?

YES

IS RECLINER MOTOR NORMAL?

REPAIR OR REPLACE THE RECLINER
SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS 3 T-11 ,
6 T-11 , 2 T-11 , 5 T-11 AND 4 T-11

REPAIR OR REPLACE THE RECLINER
MOTOR

NO

WIRING SYSTEM 8D – 511

Passenger Seat

1. Power Seat Does Not Operate At Any Direction

IS THE CIRCUIT BREAKER C/B-2 (30A) NORMAL?

YES

IS THE GROUND SECURELY GROUNDED?

REPLACE THE CIRCUIT BREAKER

NO

YES

GROUND IT SECURELY

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN
OPEN CIRCUIT 2 T-9 AND THE GROUND

REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN CIRCUIT BREAKER AND 1 T-9

NO

IS THE BATTERY VOLTAGE APPLIED BETWEEN 1 T-9
AND GROUND?

8D – 512 WIRING SYSTEM

2. Sliding Mechanism Does Not Operate

IS SLIDE SWITCH NORMAL?

YES

IS SLIDE MOTOR NORMAL?

REPAIR OR REPLACE THE SLIDE
SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS 1 T-13
AND 2 T-13

REPAIR OR REPLACE THE SLIDE
MOTOR

NO

3. Reclining Mechanism Does Not Operate

IS RECLINER SWITCH NORMAL?

YES

IS RECLINER MOTOR NORMAL?

REPAIR OR REPLACE THE RECLINER
SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS 5 T-12 ,
3 T-12 , 6 T-12 , 2 T-12 AND 4 T-12

REPAIR OR REPLACE THE RECLINER
MOTOR

NO

WIRING SYSTEM 8D – 513

Shift On The Fly System