Opel Frontera UBS. Service manual — part 2802
8D–408
WIRING SYSTEM
ID Code Registration
There are four kinds of ID codes which can be registered,
for which these three modes, ID code new registration, ID
code additional registration and ID code check, are
available.
ID Code New Registration
This procedure erases all registered ID codes and
registers a new received ID code instead.
Step
Action
Yes
No
1. Open the driver’s side door.
2. Turn the starter switch off.
Is the action complete?
Turn the starter switch to ACC position and then off three times
within five seconds after step 1.
Is the action complete within five seconds?
Close the door and then open it two times within ten seconds after
step 2.
Is the action complete within ten seconds?
1. Turn the starter switch to ACC position and then off five times.
2. Close the door and then open it.
NOTE: This step must be performed within ten seconds after step
3.
Is the action complete?
The control unit makes lock/unlock response once with interval of
one second.
Is the response complete?
Operate the lock or unlock button of transmitter within twenty
seconds after step 5.
Is the action complete?
The control unit makes lock/unlock response once with interval of
one second as ID temporary registration.
Is the response complete?
Operate the lock or unlock button of transmitter within twenty
seconds after step 7.
Is the action complete?
The control unit compares temporary registered ID code with
receiving ID code.
Is temporary registered ID code the same as receiving ID code?
The control unit makes lock/unlock response three times with
interval of one second.
Is the response complete?
The control unit erases all registered ID codes and registers new
ID code.
Is the registration complete?
1
2
3
4
5
6
7
8
9
10
11
Go to Step 2
Go to Step 3
Go to Step 4
Go to Step 5
Go to Step 6
Go to Step 7
Go to Step 8
Go to Step 9
Go to Step 11
Finished
Go to Step 12
—
Finished
Finished
Finished
—
Finished
—
Finished
Go to Step 11
—
Go to Step 13
WIRING SYSTEM
8D–409
Step
Action
Yes
No
The control unit makes lock/unlock response once with interval of
one second.
Is the response complete?
The control unit makes lock/unlock response three times with
interval of one second.
Is the response complete?
12
13
Finished
Finished
—
—
Step
Action
Yes
No
1. Open the driver’s side door.
2. Turn the starter switch off.
Is the action complete?
Turn the starter switch to ACC position and then off three times
within five seconds after step 1.
Is the action complete within five seconds?
Close the door and then open it two times within ten seconds after
step 2.
Is the action complete within ten seconds?
1. Turn the starter switch to ACC position and then off three
times.
2. Close the door and then open it.
NOTE: This step must be performed within ten seconds after step
3.
Is the action complete?
The control unit makes lock/unlock response two times with
interval of one second.
Is the response complete?
Operate the lock or unlock button of transmitter within twenty
seconds after step 5.
Is the action complete?
The control unit makes lock/unlock response two times with
interval of one second as ID temporary registration.
Is the response complete?
Operate the lock or unlock transmitter within twenty seconds after
step 7.
Is the action complete?
The control unit compares temporary registered ID code with
receiving ID code.
Is temporary registered ID code the same as receiving ID code?
The control unit makes lock/unlock response three times with
interval of one second.
Is the response complete?
The control unit registers new ID code.
Is the registration complete?
1
2
3
4
5
6
7
8
9
10
11
Go to Step 2
Go to Step 3
Go to Step 4
Go to Step 5
Go to Step 6
Go to Step 7
Go to Step 8
Go to Step 9
Go to Step 11
Finished
Go to Step 12
—
Finished
Finished
Finished
—
Finished
—
Finished
Go to Step 10
—
Go to Step 13
ID Code Additional Registration
This procedure additionally registers a new received ID
code with holding registered ID codes. When total
number of registered ID codes and newly registered ID
code exceeds four, they are erased in order of older one.
8D–410
WIRING SYSTEM
Step
Action
Yes
No
The control unit makes lock/unlock response once with interval of
one second.
Is the response complete?
The control unit makes lock/unlock response three times with
interval of one second.
Is the response complete?
12
13
Finished
Finished
—
—
Step
Action
Yes
No
1. Open the driver’s side door.
2. Turn the starter switch off.
Is the action complete?
Turn the starter switch to ACC position and then off three times
within five seconds after step 1.
Is the action complete within five seconds?
Close the door and then open it two times within ten seconds after
step 2.
Is the action complete within ten seconds?
1. Turn the starter switch to ACC position and then off.
2. Close the door and then open it.
NOTE: This step must be performed within ten seconds after step
3.
Is the action complete?
The control unit makes lock/unlock response twice as many the
number of registered ID code with interval of two seconds. (In case
of no registered code, the response is made ten times.)
Is the response complete?
1
2
3
4
5
Go to Step 2
Go to Step 3
Go to Step 4
Go to Step 5
Finished
—
Finished
Finished
Finished
—
ID Code Check
This procedure checks how many kinds of ID code are
registered.
Step
Action
Yes
No
Open the driver’s side door.
Is the action complete?
Lock the door and then unlock it three times within ten seconds
after step 1.
Is the action complete within five seconds?
Close the door and then open it two times within ten seconds after
step 2.
Is the action complete within ten seconds?
1
2
3
Go to Step 2
Go to Step 3
Go to Step 4
—
Finished
Finished
Anti–theft horn, as an answer back function for the
transmitter operation, changes from available into
unavailing or from unavailing into available by this
procedure.
Answer Back (Anti–theft Horn Operation) Change Mode
WIRING SYSTEM
8D–411
Step
Action
Yes
No
1. Lock the door and unlock it three times.
2. Close the door and then open it.
NOTE: This step must be performed within ten seconds after step
3.
Is the action complete?
Answer back mode changes.
Is this step complete?
The control unit makes lock/unlock response once with interval of
one second.
Is the response complete?
The control unit makes lock/unlock response three times with
interval of one second.
Is the response complete?
4
5
6
7
Go to Step 5
Go to Step 6
Finished
Finished
Finished
Go to Step 7
—
—
Anti–theft & Keyless Entry Control
Unit/Transmitter Replacement
Anti–theft & Keyless Entry Control Unit
Replacement
1. Remove and install the control unit.
●
Refer to Anti–theft & Keyless Entry Control Unit
Removal and Installation in this section.
2. Register ID code.
●
Refer to ID Code Registration in this section.
3. Check that the keyless entry system works normally.
Transmitter Replacement
1. Prepare a new transmitter.
2. Register ID code.
●
Refer to ID Code Registration in this section.
3. Check that the keyless entry system works normally.
Transmitter Battery Replacement
1. Remove a screw to remove the cover.
2. Remove the batteries.
3. Set the new batteries into the transmitter.
4. Install the cover to the transmitter.
5. Check that the keyless entry system works normally.