Opel Frontera UBS. Service manual — part 223
POWER ASSISTED BRAKE SYSTEM 5C – 37
INSTALLATION
7. Switch
•
Adjust the stoplight switch to the specified
clearance (between switch housing and brake
pedal) by rotating the switch housing.
Clearance
mm (in)
0 – 0.2 (0 – 0.008)
NOTE:
While adjusting the installation of the stoplight
switch, make sure that the threaded part of the
stoplight switch does not push the brake pedal.
6. Lock Nut
5. Stoplight Switch Connector
4. Instrument Panel Driver Lower Cover Assembly
3. Lower Cluster Assembly
2. Front Console Assembly
1. Shift Knob
(A)
5C – 38 POWER ASSISTED BRAKE SYSTEM
FLUID RESERVOIR TANK
2
4
1
3
Removal Steps
1.
Electrical connector
2.
Retainer
3.
Fluid reservoir
4.
O-ring
Installation Steps
To install, follow the removal steps in the
reverse order.
REMOVAL
NOTE:
Before removing fluid reservoir, remove brake fluid
from fluid reservoir.
1. Electrical Connector
2. Retainer
3. Fluid Reservoir
•
The fluid level sensor is built into the fluid
reservoir. It cannot be removed for servicing.
4. O-ring
INSTALLATION
To install, follow the removal steps in the reverse
order, noting the following points;
4. O-ring
•
O-ring must be set onto the fluid reservoir, before
installing fluid reservoir.
Retainer
Fluid reservoir
O-ring
POWER ASSISTED BRAKE SYSTEM 5C – 39
MASATER CYLINDER ASSEMBLY
6
2
1
5
3
4a
4b
Removal Steps
1.
Electrical connector
2.
Brake pipes
3.
2 attaching nuts
4a. P&B valve and bracket
4b. 3-way connector and bracket (Vehicle
with LSPV only)
5.
Master cylinder
6.
Spacer and 2 gaskets
Installation Steps
To install, follow the removal steps in the
reverse order.
This illustration is based on the LHD model.
330RW015
5C – 40 POWER ASSISTED BRAKE SYSTEM
REMOVAL
CAUTION:
When removing master cylinder from vacuum
booster, be sure to get rid of the internal negative
pressure of the vacuum booster (by, for instance,
disconnecting vacuum hose) in advance.
If any negative pressure remains in the vacuum
booster, the piston may possibly come out when the
master cylinder is being removed, letting the brake
fluid run out.
While removing master cylinder, further, do not hold
the piston as it can be easily pulled out.
Outside surface of the piston is the surface on which
seals are to slide. Care should be taken to keep the
surface free of cuts and dents.
1. Electrical Connector
2. Brake Pipes
•
After disconnecting the brake pipe, cap or tape
the openings of the brake pipe to prevent the
entry of foreign matter.
3. 2 Attaching Nuts
4a. P & B Valve and Bracket
4b.3-way Connector and Bracket (Vehicle with LSPV
Only)
5. Master Cylinder
6. Spacer and 2 Gaskets
INSTALLATION
6. Spacer and 2 Gaskets
5. Master Cylinder
•
When replacing the master cylinder or vacuum
booster or both, always measure the vacuum
booster push rod protrusion and adjust it as
necessary. (Refer to Vacuum Booster Assembly in
this section.)
4a. P & B Valve and Bracket
4b.3-way Connector and Bracket (Vehicle with LSPV
Only)
3. 2 Attaching Nuts
•
Tighten the attaching nuts to the specified torque.
Attaching Nut Torque
N·m (kg·cm / lb·in)
13 (130 / 113)
2. Brake Pipes
•
Tighten the brake pipe to the specified torque.
Brake Pipe Torque
N·m (kg·m / lb·ft)
Master Cylinder Side
Others
12 (1.2 / 9)
16 (1.6 / 12)
1. Electrical Connector