Nissan X-Trail 32. Instruction — part 1728
PWC-14
< SYSTEM DESCRIPTION >
SYSTEM
Fail Safe
INFOID:0000000010735208
FAIL-SAFE CONTROL
Power window main switch switches power window operation to fail-safe control when malfunction is detected
in encoder signal that detects up/down speed and direction of door glass. Power window main switch switches
power window operation to fail-safe control when error beyond regulation value is detected between the fully
closed position and the actual position of the glass.
It changes to condition before initialization and the following functions do not operate when power window
main switch switched power window operation to fail-safe control.
• Auto-up operation
• Anti-pinch function
Perform initial operation to recover when power window main switch switched power window operation to fail-
safe mode. However, it power window main switch switched power window operation back to fail-safe control
when malfunction is found in power window main switch or front power window motor (driver side).
Error
Error condition
Pulse sensor malfunction
When only one side of pulse signal is detected for more than the specified time during glass open/
close operation
Both pulse sensors mal-
function
When both pulse signals are not detected for more than the specified time during glass open/close
operation.
Pulse direction malfunc-
tion
When the pulse signal detected during glass open/close operation continues in the condition that the
drive direction of power window motor is operating in the opposite direction for the specified time or
longer
Glass recognition position
malfunction 1
When it detects the error between glass fully closed position in power window main switch memory
and actual fully closed position during glass open/close operation is more than the specified value.
Glass recognition position
malfunction 2
When it detects pulse count more than the value of glass full stroke during glass open/close opera-
tion.
BCM (BODY CONTROL MODULE)
PWC-15
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
ECU DIAGNOSIS INFORMATION
BCM (BODY CONTROL MODULE)
List of ECU Reference
INFOID:0000000010735209
ECU
Reference
BCM
PWC-16
< ECU DIAGNOSIS INFORMATION >
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH
Reference Value
INFOID:0000000010735210
TERMINAL LAYOUT
PHYSICAL VALUES
POWER WINDOW MAIN SWITCH
LHD models
JMKIA5634ZZ
Terminal No.
(Wire color)
Description
Condition
Voltage
+
–
Signal name
Input/
Output
1
(B)
Ground
Ground
—
—
0 – 1 V
2
(LA/GR)
Ground
Front power window motor
(passenger side) DOWN
signal
Output
When front RH switch in
power window main switch
is DOWN at operated.
9 – 16 V
4
(R)
Ground
Encoder signal 2
Input
When front power window
motor (driver side) operates.
5
(W)
Ground
Encoder signal 1
Input
When front power window
motor (driver side) operates.
6
(P)
Ground
Rear power window motor RH
DOWN signal
Output
When rear RH switch in
power window main switch
is DOWN at operated.
9 – 16 V
7
(LG)
Ground
Rear power window motor RH
UP signal
Output
When rear RH switch in
power window main switch
is UP at operated.
9 – 16 V
8
(LA/Y)
Ground
Rear power window motor LH
DOWN signal
Output
When rear LH switch in
power window main switch
is DOWN at operated.
9 – 16 V
9
(LA/W)
Ground
Rear power window motor LH
UP signal
Output
When rear LH switch in
power window main switch
is UP at operated.
9 – 16 V
JMKIA0070GB
JMKIA0070GB
POWER WINDOW MAIN SWITCH
PWC-17
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
PHYSICAL VALUES
POWER WINDOW MAIN SWITCH
RHD models
10
(SB)
Ground
Ignition ON power supply
Input
Ignition switch ON
9 – 16 V
Other than above
0 – 1 V
12
(Y)
Ground
Encoder ground
—
—
0 – 1 V
14
(G)
Ground
Encoder power supply
Output
Ignition switch ON
9 – 16 V
16
(LA/SB)
Ground
Front power window motor
(passenger side) UP signal
Output
When front RH switch in
power window main switch
is UP at operated.
9 – 16 V
17
(LA/L)
Ground
Front power window motor
(driver side) UP signal
Output
When front LH switch in
power window main switch
is UP at operated.
9 – 16 V
18
(LA/R)
Ground
Battery power supply
Input
—
9 – 16 V
19
(LA/BR)
Ground
Front power window motor
(driver side) DOWN signal
Output
When front LH switch in
power window main switch
is DOWN at operated.
9 – 16 V
Terminal No.
(Wire color)
Description
Condition
Voltage
+
–
Signal name
Input/
Output
Terminal No.
(Wire color)
Description
Condition
Voltage
+
-
Signal name
Input/
Output
1
(B)
Ground
Ground
—
—
0 – 1 V
2
(LA/GR)
Ground
Front power window motor
(passenger side) DOWN
signal
Output
When front LH switch in
power window main switch
is DOWN at operated.
9 – 16 V
4
(P)
Ground
Encoder signal 2
Input
When front power window
motor (driver side) operates.
5
(W)
Ground
Encoder signal 1
Input
When front power window
motor (driver side) operates.
6
(LA/L)
Ground
Rear power window motor RH
DOWN signal
Output
When rear RH switch in
power window main switch
is DOWN at operated.
9 – 16 V
7
(LA/G)
Ground
Rear power window motor RH
UP signal
Output
When rear RH switch in
power window main switch
is UP at operated.
9 – 16 V
JMKIA0070GB
JMKIA0070GB