Nissan X-Trail 32. Instruction — part 1362
DIAGNOSIS AND REPAIR WORKFLOW
HA-107
< BASIC INSPECTION >
[QR25DE]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000011006104
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
NNIIA0143GB
HA-108
< BASIC INSPECTION >
[QR25DE]
DIAGNOSIS AND REPAIR WORKFLOW
>> GO TO 2.
2.
SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the inter-
viewed symptom.
Insufficient cooling/heating>>GO TO 3.
Refrigerant leakage>>GO TO 6.
Noise >> GO TO 7.
3.
CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system. Refer to
(AUTOMATOC AIR
CONDITIONING),
(MANUAL AIR CONDITIONING).
Is A/C control system normal?
YES
>> GO TO 4.
NO
>> GO TO 8.
4.
PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Refer to
.
>> GO TO 5.
5.
TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify
the malfunctioning part. Refer to
Low refrigerant charge>>GO TO 6.
Except above>>GO TO 8.
6.
CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Refer to
.
>> GO TO 8.
7.
TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Refer to
.
>> GO TO 8.
8.
MALFUNCTION PART REPAIR
Repair or replace the malfunctioning part.
>> GO TO 9.
9.
REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES
>> INSPECTION END
NO
>> GO TO 2.
REFRIGERANT
HA-109
< BASIC INSPECTION >
[QR25DE]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
REFRIGERANT
Description
INFOID:0000000011006105
CONNECTION OF SERVICE TOOLS AND EQUIPMENT
Leak Test
INFOID:0000000011006106
CHECK REFRIGERANT LEAKAGE USING FLUORESCENT LEAK DETECTION DYE
1.
Install a fender cover
.
2.
Wear UV safety goggles
provided with refrigerant dye leak detection kit.
3.
Connect power cable
of UV lamp
to positive and negative terminals of the battery
.
4.
Press UV lamp switch
and check A/C system for refrigerant leakage. (Where refrigerant leakage
occurs, fluorescent leak detection dye appears in green color.)
Shut-off valve
A/C service valve
Recovery/recycling/recharging
equipment
Vacuum pump
Manifold gauge set
Refrigerant container (HFC-134a)
Weight scale
Preferred (best) method
Alternative method
For charging
JSIIA0258ZZ
RJIA3815J
HA-110
< BASIC INSPECTION >
[QR25DE]
REFRIGERANT
WARNING:
Never look directly into UV lamp light source.
NOTE:
• For continuous operating time of UV lamp, follow the manufacturer operating instructions.
• Illuminate piping joints from different angles using UV lamp and check that there is no leakage.
• Use a mirror in area that is difficult to see to check refrigerant leakage.
• Refrigerant leakage from evaporator can be detected by soaking cotton swab or a similar material with
drain hose water and illuminating it using UV lamp.
• Dust, dirt, and packing materials adhesive used for condenser, evaporator, and other locations may flu-
oresce. Be careful not to misidentify leakage.
5.
Repair or replace parts where refrigerant leakage occurs and wipe off fluorescent leak detection dye.
NOTE:
Completely wipe off fluorescent leak detection dye from gaps between parts, screw threads, and others
using a cotton swab or similar materials.
6.
Use a UV lamp to check that no fluorescent leak detection dye remains after finishing work.
WARNING:
Never look directly into UV lamp light source.
NOTE:
• For continuous operating time of UV lamp, follow the manufacturer operating instructions.
• Dust, dirt, and packing materials adhesive used for condenser, evaporator, and other locations may flu-
oresce. Be careful not to misidentify leakage.
CHECK REFRIGERANT LEAKAGE USING ELECTRICAL LEAK DETECTOR
WARNING:
Never check refrigerant leakage while the engine is running.
CAUTION:
Be careful of the following items so that inaccurate checks or misidentifications are avoided.
• Never allow refrigerant vapor, shop chemical vapors, cigarette smoke, or others around the vehicle.
• Always check refrigerant leakage in a low air flow environment so that refrigerant may not disperse
when leakage occurs.
1.
Stop the engine.
2.
Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.
3.
Check that A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or more when temperature
is 16
°
C (61
°
F) or more. When pressure is lower than the specified value, recycle refrigerant completely
and fill refrigerant to the specified level.
NOTE:
Leakages may not be detected if A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or
less when temperature is less than 16
°
C (61
°
F).
4.
Clean area where refrigerant leakage check is performed, and check refrigerant leakage along all sur-
faces of pipe connections and A/C system components using electrical leak detector probe.
CAUTION:
• Continue checking when a leakage is found. Always continue and complete checking along all
pipe connections and A/C system components for additional leakage.
• When a leakage is detected, clean leakage area using compressed air and check again.
• When checking leakage of cooling unit inside, always clean inside of drain hose so that the
probe surface may not be exposed to water or dirt.
NOTE:
• Always check leakage starting from high-pressure side and continue to low-pressure side.
• When checking leakage of cooling unit inside, operate blower fan motor for 15 minutes or more at the
maximum fan speed while the engine is stopped, and then insert electrical leak detector probe into drain
hose and hold for 10 minutes or more.
• When disconnecting shut-off valve that is connected to A/C service valve, always evacuate remaining
refrigerant so that misidentification can be avoided.
5.
Repair or replace parts where refrigerant leakage is detected. (Leakage is detected but leakage area is
unknown. GO TO 6.)
6.
Start the engine and set A/C control in the following conditions.
• A/C switch ON
• Air flow: VENT (ventilation)