Nissan X-Trail 32. Instruction — part 1340
REFRIGERANT
HA-19
< BASIC INSPECTION >
[R9M (EXCEPT FOR RUSSIA)]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
REFRIGERANT
Description
INFOID:0000000010999974
CONNECTION OF SERVICE TOOLS AND EQUIPMENT
Leak Test
INFOID:0000000010999975
CHECK REFRIGERANT LEAKAGE USING ELECTRICAL LEAK DETECTOR
WARNING:
Never check refrigerant leakage while the engine is running.
CAUTION:
Be careful of the following items so that inaccurate checks or misidentifications are avoided.
• Never allow refrigerant vapor, shop chemical vapors, cigarette smoke, or others around the vehicle.
• Always check refrigerant leakage in a low air flow environment so that refrigerant may not disperse
when leakage occurs.
1.
Stop the engine.
2.
Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.
3.
Check that A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or more when temperature
is 16
°
C (61
°
F) or more. When pressure is lower than the specified value, recycle refrigerant completely
and fill refrigerant to the specified level.
NOTE:
Leakages may not be detected if A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or
less when temperature is less than 16
°
C (61
°
F).
4.
Clean area where refrigerant leakage check is performed, and check refrigerant leakage along all sur-
faces of pipe connections and A/C system components using electrical leak detector probe.
CAUTION:
• Continue checking when a leakage is found. Always continue and complete checking along all
pipe connections and A/C system components for additional leakage.
• When a leakage is detected, clean leakage area using compressed air and check again.
• When checking leakage of cooling unit inside, always clean inside of drain hose so that the
probe surface may not be exposed to water or dirt.
Shut-off valve
A/C service valve
Recovery/recycling recharging
equipment
Vacuum pump
Manifold gauge set
Refrigerant container (HFO-1234yf)
Weight scale
Preferred (best) method
Alternative method
For charging
JSIIA0258ZZ
HA-20
< BASIC INSPECTION >
[R9M (EXCEPT FOR RUSSIA)]
REFRIGERANT
NOTE:
• Always check leakage starting from high-pressure side and continue to low-pressure side.
• When checking leakage of cooling unit inside, operate blower fan motor for 15 minutes or more at the
maximum fan speed while the engine is stopped, and then insert electrical leak detector probe into drain
hose and hold for 10 minutes or more.
• When disconnecting shut-off valve that is connected to A/C service valve, always evacuate remaining
refrigerant so that misidentification can be avoided.
5.
Repair or replace parts where refrigerant leakage is detected. (Leakage is detected but leakage area is
unknown. GO TO 6.)
6.
Start the engine and set A/C control in the following conditions.
• A/C switch ON
• Air flow: VENT (ventilation)
• Intake door position: Recirculation
• Temperature setting: Full cold
• Fan speed: Maximum speed set
7.
Run the engine at approximately 1,500 rpm for 2 minutes or more.
8.
Stop the engine. Check again for refrigerant leakage. GO TO 4.
WARNING:
Never get burned when the engine is hot.
NOTE:
• Start refrigerant leakage check immediately after the engine is
stopped.
• When refrigerant circulation is stopped, pressure on the low-
pressure side rises gradually, and after this, pressure on the
high-pressure side falls gradually.
• The higher the pressure is, the easier it is to find the refriger-
ant leakage.
Recycle Refrigerant
INFOID:0000000010999976
WARNING:
• Always use HFO-1234yf for A/C refrigerant. If CFC-12 or HFC-134a is accidentally charged, compres-
sor is damaged due to insufficient lubrication.
• Always observe and follow precautions described on refrigerant container. Incorrect handling may
result in an explosion of refrigerant container, frostbite, or the loss of eyesight.
• Never breathe A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose, or
throat.
• Never allow HFO-1234yf to be exposed to an open flame or others because it generates poisonous
gas when in contact with high temperature objects. Keep workshop well ventilated.
1.
Perform lubricant return operation. Refer to
HA-22, "Perform Lubricant Return Operation"
. (If refrigerant or
lubricant leakage is detected in a large amount, omit this step, and then GO TO 2.)
CAUTION:
Never perform lubricant return operation if a large amount of refrigerant or lubricant leakage is
detected.
2.
Check gauge pressure readings of recovery/recycling/recharging equipment. When remaining pressure
exists, recycle refrigerant from high-pressure hose and low-pressure hose.
NOTE:
Follow manufacturer instructions for the handling or maintenance of the equipment. Never fill the equip-
ment with non-specified refrigerant.
3.
Remove A/C service valve cap from the vehicle.
4.
Connect recovery/recycling/recharging equipment to A/C service valve.
5.
Operate recovery/recycling/recharging equipment, and recycle refrigerant from the vehicle.
6.
Evacuate air for 10 minutes or more to remove any remaining refrigerant integrated to compressor lubri-
cant, etc.
SHA839E
REFRIGERANT
HA-21
< BASIC INSPECTION >
[R9M (EXCEPT FOR RUSSIA)]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
7.
Refrigerant recycle operation is complete.
Charge Refrigerant
INFOID:0000000010999977
WARNING:
• Always use HFO-1234yf for A/C refrigerant. If CFC-12 or HFC-134a is accidentally charged, compres-
sor is damaged due to insufficient lubrication.
• Always observe and follow precautions described on refrigerant container. Incorrect handling may
result in an explosion of refrigerant container, frostbite, or the loss of eyesight.
• Never breathe A/C refrigerant and lubricant vapor or mist. Exposure my irritate eyes, nose, or throat.
• Never allow HFO-1234yf to be exposed to an open flame or others because it generates poisonous
gas when in contact with high temperature objects. Keep workshop well ventilated.
1.
Connect recovery/recycling/recharging equipment to the A/C service valve.
2.
Operate recovery/recycling/recharging equipment, and evacuate air from A/C system for 25 minutes or
more.
CAUTION:
Evacuate air for 15 minutes or more if the parts are replaced.
3.
Check the airtightness of A/C system for 25 minutes or more. If pressure rises more than the specified
level, charge A/C system with approximately 200 g (0.4 lb) refrigerant and check that there is no refriger-
ant leakage. Refer to
CAUTION:
Check the airtightness for 15 minutes or more if the parts are replaced.
4.
If parts other than compressor are replaced, fill compressor lubricant according to parts that are replaced.
5.
Charge the specified amount of refrigerant to A/C system.
6.
Check that A/C system operates normally.
7.
Disconnect recovery/recycling/recharging equipment. (Collect the refrigerant from the high-pressure hose
and low-pressure hose of recovery/recycling/recharging equipment.)
8.
Install A/C service valve cap.
9.
Refrigerant charge is complete.
HA-22
< BASIC INSPECTION >
[R9M (EXCEPT FOR RUSSIA)]
LUBRICANT
LUBRICANT
Description
INFOID:0000000010999978
MAINTENANCE OF LUBRICANT LEVEL
The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill com-
pressor with lubricant when replacing A/C system parts or when a large amount of refrigerant leakage is
detected. It is important to always maintain lubricant level within the specified level. Otherwise, the following
conditions may occur.
• Insufficient lubricant amount: Stuck compressor
• Excessive lubricant amount: Insufficient cooling (caused by insufficient heat exchange)
Inspection
INFOID:0000000010999979
If a compressor is malfunctioning (internal noise, insufficient cooling), check the compressor oil.
1.
COMPRESSOR OIL JUDGMENT
1.
Remove the compressor. Refer to
HA-30, "Removal and Installation"
.
2.
Sample a compressor oil and judge on the figure.
Judgement result 1>>Replace compressor only.
Judgement result 2>>Replace compressor and condenser & liquid tank assembly.
Perform Lubricant Return Operation
INFOID:0000000010999980
CAUTION:
If a large amount of refrigerant or lubricant leakage is detected, never perform lubricant return opera-
tion.
1.
Start the engine and set to the following conditions.
• Engine speed: Idling to 1,200 rpm
• A/C switch: ON
• Fan speed: Maximum speed set
• Intake door position: Recirculation
• Temperature setting: Full cold
2.
Perform lubricant return operation for approximately 10 minutes.
3.
Stop the engine.
4.
Lubricant return operation is complete.
Lubricant Adjusting Procedure for Components Replacement Except Compressor
INFOID:0000000010999981
Fill with lubricant for the amount that is calculated according to the following conditions.
Example: Lubricant amount to be added when replacing evaporator and condenser&liquid tank assembly [m
(Imp fl oz.)] = 35 (1.2) + 20 (0.7) +
α
Name
: ND-OIL12
JSIIA0927GB