Nissan X-Trail 32. Instruction — part 1166
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
EXL-121
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010788806
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front combination lamp LH internal circuit
- LED (Daytime running light)
- Control circuit
- Harness
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the daytime running light LH power supply circuit until the daytime running light
ON conditions are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “DTRL LH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the daytime running light LH power supply circuit, and
damage accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not
turn ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
PCS-60, "Removal and Installation"
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Start engine.
3.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
4.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-121, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-44, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010788807
1.
CHECK DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT (SHORT)
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B20CB
DTRL LH PWR SPLY CIRC
(Daytime running light left hand power sup-
ply circuit)
[CIRC
SHORT TO
GRND]
When daytime running light ON conditions are satisfied
(smart FET inside IPDM E/R is ON), and overcurrent is
detected in the daytime running light LH power supply cir-
cuit.
Monitor item
Monitor status
DTRL LH CIRC MALFUNCTN
0
1
EXL-122
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect IPDM E/R connector and front combination lamp LH connector.
3.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK DAYTIME RUNNING LIGHT LH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “DAYTIME RUNNING LIGHT” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp LH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-60, "Removal and Installation"
3.
CHECK DAYTIME RUNNING LIGHT LH
Check the daytime running light LH. Refer to
EXL-122, "Component Inspection"
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-191, "Removal and Installation"
.
Component Inspection
INFOID:0000000010788808
1.
CHECK DAYTIME RUNNING LIGHT LH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp LH connector.
3.
Check resistance of front combination lamp LH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-191, "Removal and Installation"
.
IPDM E/R
—
Continuity
Connector
Terminal
E148
49
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp LH
Connector
Terminal
E156
5
Ground
DAYTIME
RUNNING
LIGHT
On
9 – 16 V
Off
0 – 1 V
Front combination lamp LH
Resistance
Terminal
5
8
Except 0
Ω
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
EXL-123
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010788809
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front combination lamp LH internal circuit
- LED [Headlamp (HI)]
- LED headlamp control module
- Harness
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the headlamp (HI) LH power supply circuit until the headlamp (HI) ON conditions
are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “HL (HI) LH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the headlamp (HI) LH power supply circuit, and dam-
age accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not turn
ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
60, "Removal and Installation"
.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Turn ignition switch ON.
3.
Turn lighting switch 2ND, and lighting switch HI.
4.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
5.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-123, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-44, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010788810
1.
CHECK HEADLAMP (HI) LH POWER SUPPLY CIRCUIT (SHORT)
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B20CE
HL (HI) LH PWR SPLY CIRC
[Headlamp (high) left hand power supply
circuit]
[CIRC
SHORT TO
GRND]
When headlamp (HI) ON conditions are satisfied (smart
FET inside IPDM E/R is ON), and overcurrent is detected
in the headlamp (HI) LH power supply circuit.
Monitor item
Monitor status
HL (HI) LH CIRC MALFUNCTN
0
1
EXL-124
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Turn lighting switch OFF.
3.
Disconnect IPDM E/R connector and front combination lamp LH connector.
4.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK HEADLAMP (HI) LH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “HEADLAMP (HI)” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp LH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-60, "Removal and Installation"
3.
CHECK HEADLAMP (HI) LH
Check the headlamp (HI) LH. Refer to
EXL-124, "Component Inspection"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-191, "Removal and Installation"
.
Component Inspection
INFOID:0000000010788811
1.
CHECK HEADLAMP (HI) LH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp LH connector.
3.
Check resistance of front combination lamp LH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-191, "Removal and Installation"
.
IPDM E/R
—
Continuity
Connector
Terminal
E149
59
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp LH
Connector
Terminal
E156
2
Ground
HEADLAMP
(HI)
On
9 – 16 V
Off
0 – 1 V
Front combination lamp LH
Resistance
Terminal
2
1
Except 0