Nissan Teana J32. Instruction — part 693
AUTOMATIC AIR CONDITIONER SYSTEM
HAC-141
< FUNCTION DIAGNOSIS >
[WITH 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
WITH INTELLIGENT AIR CONDITIONER SYSTEM : Component Description
INFOID:0000000003885179
Component
Description
Refrigerant pressure sensor
Gas sensor
HAC-175, "WITH INTELLIGENT AIR CONDITIONER SYSTEM :
Description"
Compressor
Ambient sensor
Intake door motor
Air mix door motor (driver side)
Air mix door motor (passenger side)
Mode door motor
Sunload sensor
In-vehicle sensor
A/C auto amp.
Intake sensor
Blower motor
HAC-142
< FUNCTION DIAGNOSIS >
[WITH 7 INCH DISPLAY]
PLASMACLUSTER SYSTEM
PLASMACLUSTER SYSTEM
WITH INTELLIGENT AIR CONDITIONER SYSTEM
WITH INTELLIGENT AIR CONDITIONER SYSTEM : System Diagram
INFOID:0000000003884708
WITH INTELLIGENT AIR CONDITIONER SYSTEM : System Description
INFOID:0000000003884709
• Plasmacluster
™
ion generation function, which generates ions inactivating bacteria and supplies to the pas-
senger compartment through air blown from air conditioner, has been adopted.
• Airborne mold and bacteria in the passenger compartment are inactivated by the effect of Plasmacluster
™
ion.
• Plasmacluster
™
ion generation function is switched between 2 operation modes (clean mode and ion control
mode) automatically, and maintain the ion balance in the passenger compartment close to that in nature.
• The operating condition is displayed in the “ION” indicator in the display.
NOTE:
• Plasmacluster
™
ion technology developed by Sharp Corporation is installed in this item.
• Plasmacluster
™
is a trademark of Sharp Corporation.
OPERATION DESCRIPTION
• The Plasmacluster
™
ion generation function operates synchronized with the blower motor. The Plasmaclus-
ter
™
ion generation function operates when the blower motor operates.
• 2 ion generation modes (clean mode and ion control mode) are switched every 15 minutes while blower
motor turns ON with ignition switch ON.
• When the clean switch is turned ON, Plasmacluster
™
ion generation function extends the operation time of
the clean mode to approximately 30 minutes for deactivating impurities more actively.
NOTE:
When the clean switch is not ON
• Ignition switch: OFF
• Blower motor: OFF
• Mode position: Defroster (DEF)
• Ambient temperature: At about 0
°
C (32
°
F) or below [Reactivate at about 2
°
C (36
°
F) or above]
• When the gas sensor is malfunctioning
• When the blower motor is stopped, the Plasmacluster
™
ion generation function also stops operating
(“CLEAN” and “ION” indicators are OFF).
JPIIA1004GB
Condition
Clean mode
Ion control mode
Clean switch: OFF
15 minutes
15 minutes
Clean switch: ON
30 minutes
15 minutes
PLASMACLUSTER SYSTEM
HAC-143
< FUNCTION DIAGNOSIS >
[WITH 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
1.
Clean mode operation
Ion indicator (blue) (1) in the display is turns ON as per the fol-
lowings.
• Approximately 15 minutes after starting the blower motor.
• Approximately 30 minutes after the clean switch is turned ON
while the blower motor is operating.
• Clean mode is switched to operate, 15 minutes after ion con-
trol mode in operation.
2.
Ion control mode operation
Ion indicator (green) in the display is turns ON as per the follow-
ings.
• Ion control mode is switched to operate, 15 minutes after
clean mode in operation.
• After approximately 30 seconds of clean mode operation time has passed while the clean switch is ON.
WITH INTELLIGENT AIR CONDITIONER SYSTEM : Component Part Location
INFOID:0000000003884710
PASSENGER COMPARTMENT
Clean mode
Emits positive and negative ions into air for deactivating impurities actively.
Ion control mode
Emits more negative ions after deactivating impurities actively in clean mode.
JSIIA1152ZZ
JPIIA0998ZZ
HAC-144
< FUNCTION DIAGNOSIS >
[WITH 7 INCH DISPLAY]
PLASMACLUSTER SYSTEM
WITH INTELLIGENT AIR CONDITIONER SYSTEM : Component Description
INFOID:0000000003884711
1.
Ion indicator
2.
A/C auto amp.
3.
Ionizer
Component
Description
A/C auto amp.
The A/C auto amp. controls ionizer ON/OFF and shifts an ion gen-
eration function.
Ion indicator
Plasmacluster ion generation function operating condition is dis-
played in the ion indicator in the display.
Ionizer
HAC-199, "WITH INTELLIGENT AIR CONDITIONER SYSTEM :
Description"