Nissan Leaf. Instruction — part 516
EVC-88
< ECU DIAGNOSIS INFORMATION >
VCM
N/CHG PORT CONNECTION
Normal charge connector is connected.
On
Normal charge connector is half-engaged
HALF
Except above
Off
Q/CHG INTERLOCK
Quick charger connector is connected.
On
Except above
Off
AC POWER TYPE
When an AC power supply is not connected
OFF
When an AC 100-120 V power supply is connected
100V
When an AC 200-240 V power supply is connected
200V
ENABLE OBC OUT PWR
Charging
When EVSE for 3.3 kW is used
3.3 kW
When EVSE for 6.0 kW is used
6.0 kW
HV BATT EMPTY
Power ON
The Li-ion battery remaining en-
ergy is sufficient.
OK
The Li-ion battery remaining en-
ergy is low.
EMPTY
OBC OUT PWR
In Normal Charging
When EVSE for 3.3 kW is used
0 – 3.3 kW
When EVSE for 6.0 kW is used
0 – 6.0 kW
In Quick Charging
0 – 50 kW
TRG HV BATT CHG LEVEL
Charging
100%
HV BATT LEVEL (%)
Depending on Li-ion battery remained energy.
0 – 100%
HV BATT LEVEL
Power ON
0 – 24 kWh
HV BATT VOLT
Power ON
200 – 403 V
HV BATT CURRENT
• READY (at idle
*
)
• Electrical load: No load
0 – 10 A
HV BATTERY TEMP
Power ON
Between the outside air tem-
perature and 50
°C (122°F)
IR SENSOR SIGNAL P-P
Power ON
3150 mV or more
CHG CNECTR LOCK RLY V
Set vehicle as stated below and operate the charge connector lock
switch to LOCK.
• Power switch: OFF
• Charge connector lock switch: OFF
• Connect EVSE to normal charge port.
0 V
⇒12V battery voltage⇒0
V
Except above
0 V
C/CNECTR LCK ACTR DUTY
Set vehicle as stated below and operate the charge connector lock
switch to LOCK.
• Power switch: OFF
• Charge connector lock switch: OFF
• Connect EVSE to normal charge port.
0%
⇒100%⇒0%
Except above
0 V
F/S RELAY
Power ON
On
F/S CHG RELAY
During quick charge
On
Except above
Off
M/C RELAY
Power ON
On
A/C RELAY
Power ON
On
Power OFF
Off
REVERSE LAMP RELAY
Power ON
Selector lever: R range
On
Selector lever: Except R range
Off
REVERSE LAMP RELAY MONI Power ON
Selector lever: R range
On
Selector lever: Except R range
Off
MONITOR ITEM
CONDITION
Values/Status
VCM
EVC-89
< ECU DIAGNOSIS INFORMATION >
D
E
F
G
H
I
J
K
L
M
A
B
EVC
N
O
P
HV P MAIN RLY ACTIV
READY
On
Power ON
Off
HV P MAIN RLY ACTIV MONI
READY
On
Power ON
Off
HV N MAIN RLY ACTIV
READY
On
Power ON
Off
HV N MAIN RLY ACTIV MONI
READY
On
Power ON
Off
HV PRE CHG RLY ACTIV
Immediately after the power OFF
⇒READY operation
Off
⇒On⇒Off
HV PRE CHG RLY ACTIV MONI Immediately after the power OFF
⇒READY operation
Off
⇒On⇒Off
Q/CHG RELAY
Quick charging
On
Except above
Off
ASCD SET VEHICLE SPEED
ASCD: Operating
The preset vehicle speed is
displayed
ASCD MAIN SW
Power ON
ASCD MAIN switch: Pressed
On
ASCD MAIN switch: Released
Off
ASCD CANCEL SW
Power ON
CANCEL switch: Pressed
On
CANCEL switch: Released
Off
RESUME/ACC SW
Power ON
RESUME/ACCELERATE
switch: Pressed
On
RESUME/ACCELERATE
switch: Released
Off
ASCD SET SW
Power ON
SET/COAST switch: Pressed
On
SET/COAST switch: Released
Off
ASCD BRAKE SW
Power ON
Brake pedal: Fully released
On
Brake pedal: Depressed
Off
STOP LAMP SW
Power ON
Brake pedal: Fully released
Off
Brake pedal: Depressed
On
ASCD CANCEL (LOW SPEED)
Power ON
NON
ASCD CANCEL (SPEED DIFF)
Power ON
NON
ASCD CRUISE LAMP
Power ON
ASCD MAIN switch: Pressed at
the 1st time
→ at the 2nd time
On
⇒Off
ASCD SET LAMP
After the ASCD MAIN switch has been pressed once, press it again. On
⇒Off
SL TARGET VEHICLE SPEED
The item is indicated, but not used.
READY COUNT
Power ON
This shows the READY cu-
mulative count
INTEG READY TIME
Power ON
This shows the READY cu-
mulative operation time
QUICK CHG COUNT
Power ON
This shows the quick charge
cumulative count
INTEG Q/CHG TIME
Power ON
This shows the quick charge
cumulative operation time
NORMAL CHG COUNT
Power ON
This shows the normal
charge cumulative count
INTEG N/CHG TIME
Power ON
This shows the normal
charge cumulative operation
time
MONITOR ITEM
CONDITION
Values/Status
E V C - 9 0
< ECU DIAGNOSIS INFORMATION >
VCM
*: Idle is the state when not driving in the READY state.
TERMINAL LAYOUT
PHYSICAL VALUES
NOTE:
Specification data are reference values.
EV SYS ACT REQ (VCM TIM-
ER)
The item is indicated, but not used.
ASCD VHCL SPD BLINK REQ
• Driving
• ASCD: ON
When vehicle speed exceeds
the set speed of ASCD
Blink
Except above
Off
DIFF WHEEL SPD LRN VAL
Power ON
± 0.02
REFRIGERANT PRESS
• READY
• Both the A/C switch and blower fan switch are ON (A/C compres-
sor is operating)
0.6 – 2.6 MPa
REGE TORQ LIMIT VAL (INV)
Normal
100%
When output is limited
0 – 98%
LIGHT CRASH JUDGMENT
When a light crash judgment signal is received from air bag diagnosis
sensor unit.
15
Except above
0
CHARGE PORT LID OPENER
Charge port lid opener switch: OFF
⇒ON
Off
⇒On⇒Off
ECO MODE
ECO mode indicator: ON
On
ECO mode indicator: OFF
Off
KICK DOWN
Power ON
Accelerator pedal: Depressed
On
MONITOR ITEM
CONDITION
Values/Status
JSCIA0588ZZ
Terminal No.
(Wire color)
Description
Condition
Value
(Approx.)
+
–
Signal name
Input/
Output
1
(B)
Ground Motor coil A U-phase
Output
Power switch: ON
9 V – 16 V
Power switch: OFF
0 V
3
(W)
Ground Electric shift sensor No. 5
Input
READY
Selector lever is held in D po-
sition
0 V
Other than the above
5 V
5
(LG)
Ground F/S relay power supply
Input
Power switch: OFF
0 V
Power switch: ON
12V BATTERY VOLTAGE
(11 – 15 V)
7
(O/L)
Ground
Electric shift sensor pow-
er supply 1
Input
Power switch: ON
5 V
VCM
EVC-91
< ECU DIAGNOSIS INFORMATION >
D
E
F
G
H
I
J
K
L
M
A
B
EVC
N
O
P
8
(Y)
Ground F/S CHG relay
Output
During quick charge
0 V
(Approx.)
Except above
12V BATTERY VOLTAGE
(11 – 15 V)
9
(SB)
Ground Parking actuator relay A
Output
Power switch: ON
0 V
Power switch: OFF
9 V – 16 V
11
(BR)
Ground 12V Battery power supply
Input
Always
12V BATTERY VOLTAGE
(11 – 15 V)
13
(SB)
Ground Motor coil A V-phase
Output
Power switch: ON
9 V – 16 V
Power switch: OFF
0 V
16
(R)
Ground Electric shift sensor No. 3
Input
READY
Selector lever is held in H
(Home) and N positions
0 V
Other than the above
5 V
17
(B)
Ground Electric shift sensor No. 1
Input
READY
Selector lever is held in R po-
sition
0 V
Other than the above
5 V
18
(Y)
Ground
R position output (selec-
tor indicator)
Output READY
Selector lever is held in R po-
sition
1 V or less
Other than the above
9 V – 16 V
19
(W)
58
(B/R)
Water pump signal
Input
• Power switch ON
• Pump operation duty: 0%
• Power switch ON
• Pump operation duty: Approx. 70%
20
(G)
58
(B/R)
Water pump signal
Input
Pump operation duty: 0%
Pump operation duty: Approx. 70%
Terminal No.
(Wire color)
Description
Condition
Value
(Approx.)
+
–
Signal name
Input/
Output
JSCIA0325ZZ
JSCIA0326ZZ
JSCIA0331ZZ
JSCIA0332ZZ
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.