Nissan Leaf. Instruction — part 491
LI-ION BATTERY
EVB-247
< UNIT DISASSEMBLY AND ASSEMBLY >
D
E
F
G
H
I
J
K
L
M
A
B
EVB
N
O
P
WARNING:
To prevent electric shock, wear insulated protective gear.
6. Install the battery temperature sensor harness (rear).
WARNING:
To prevent electric shock, wear insulated protective gear and use insulated tools.
NOTE:
Install the battery temperature sensor onto module No. MD12.
: Harness clip
JSCIA0769ZZ
JSCIA0647ZZ
EVB-248
< UNIT DISASSEMBLY AND ASSEMBLY >
LI-ION BATTERY
7. Connect the harness connector between the battery tempera-
ture sensor harness (front) and battery temperature sensor har-
ness (rear).
WARNING:
To prevent electric shock, wear insulated protective
gear.
8. Install the Li-ion battery heater RR1 and RR2. Refer to
EVB-215, "LI-ION BATTERY HEATER : Disassem-
9. Install the Li-ion battery controller.
EVB-201, "LI-ION BATTERY CONTROLLER : Removal and Installa-
10. Install the battery pack upper case.
EVB-191, "BATTERY PACK UPPER CASE : Removal and Installa-
CAUTION:
• Be sure to reinstall the high voltage harness clips in their original positions. If a clip is damaged,
replace it with a new clip before installing.
• Check the following items after installing battery pack: Refer to
.
AIR LEAK INSPECTION
ELECTRIC EQUIPOTENTIAL TEST
REAR MODULE STACK : Disassembly and Assembly
INFOID:0000000010121189
DANGER:
Since hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of
electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are
handled incorrectly. Be sure to follow the correct work procedures when performing inspection and
maintenance.
WARNING:
• Be sure to remove the service plug for shutting off high voltage circuits before performing inspec-
tion or maintenance of high voltage system harnesses and parts.
• Be sure to put the removed service plug in pocket and carry it or store it in a tool box or other con-
tainer so that another person does not accidentally connect it while work is in progress.
• Be sure to put on insulating protective gear before beginning work on the high voltage system.
• Clearly identify the persons responsible for high voltage work and ensure that other persons do not
touch the vehicle. When not working, cover high voltage components with an anti-static cover sheet
or similar item to prevent contact with other persons.
• Refer to
EVB-7, "High Voltage Precautions"
.
• If the battery pack is to be disassembled, be sure to remove the Li-ion battery controller for prevent-
ing electric shock, fire, and damage to parts.
CAUTION:
There is the possibility of a malfunction occurring if the vehicle is changed to READY status while the
service plug is removed. Therefore do not change the vehicle to READY status unless instructed to do
so in the Service Instruction.
ENVIRONMENT FOR LI-ION BATTERY DISASSEMBLY WORK
1. Must be an indoor environment.
• The environment must utilize a shutter or other means to shut out the outside environment and prevent
rain, snow, dust, or other substances from entering.
• The environment must not cause the intrusion of sweat during work, or cause condensation to occur
due to high temperature or humidity.
2. Metal powder, grease, and other foreign substances must not enter.
• The indoor environment must also prevent metal powder, grease, and other foreign substances from
entering due to maintenance performed on other vehicles and other sources during disassembly work.
JSCIA0658ZZ
LI-ION BATTERY
EVB-249
< UNIT DISASSEMBLY AND ASSEMBLY >
D
E
F
G
H
I
J
K
L
M
A
B
EVB
N
O
P
• If there is a risk of the above substances entering, take appropriate countermeasures, such as use of a
vinyl curtain or an equivalent to shut out the outside environment.
3. The floor must be dry.
• The floor must not be wet as a result of factors such as vehicle entry during rain or snow.
4. Work space
• The work space must be approximately the size of one entire vehicle.
• Take appropriate countermeasures so that persons other than the operator do not enter the work space,
such as by placing signs indicating that disassembly work is in progress.
5. Standard fire fighting equipment
• Always place a standard fire fighting equipment in the disassembly work area.
• Depending on type of fire (vehicle or battery) use standard fire fighting equipment (water or extin-
guisher).
DISASSEMBLY
1. Remove harness bracket , and from the rear module stack.
WARNING:
To prevent electric shock, wear insulated protective gear and use insulated tools.
2. Follow the following procedure and remove the bus bar from the rear module stack.
a. Remove the center bus bar cover, then remove the module ter-
minal mounting bolts .
DANGER:
•
There is the danger of electric shock caused by
contact with the terminals. Be sure to wear insulated pro-
tective gear and use insulated tools.
•
This work must not be performed by multiple opera-
tors because there is a risk of electric shock if the operators contact one another.
CAUTION:
Do not remove all bus bar covers and all module terminal mounting bolts at the same time.
JSCIA0635ZZ
JSCIA0154ZZ
EVB-250
< UNIT DISASSEMBLY AND ASSEMBLY >
LI-ION BATTERY
b. Remove the left-side bus bar cover, then remove the module ter-
minal mounting bolts .
DANGER:
•
There is the danger of electric shock caused by
contact with the terminals. Be sure to wear insulated pro-
tective gear and use insulated tools.
•
This work must not be performed by multiple opera-
tors because there is a risk of electric shock if the operators contact one another.
c.
Remove the right-side bus bar cover, then remove the module
terminal mounting bolts .
DANGER:
•
There is the danger of electric shock caused by
contact with the terminals. Be sure to wear insulated pro-
tective gear and use insulated tools.
•
This work must not be performed by multiple opera-
tors because there is a risk of electric shock if the operators contact one another.
d. Remove the voltage detection terminal mounting screws ,
then remove the bus bar from the rear module stack.
DANGER:
•
There is the danger of electric shock caused by
contact with the terminals. Be sure to wear insulated pro-
tective gear and use insulated tools.
•
This work must not be performed by multiple opera-
tors because there is a risk of electric shock if the operators contact one another.
e. Install a module terminal cover [SST: KV99111500 ( — )] (A)
onto all module terminals.
WARNING:
To prevent electric shock, wear insulated protective
gear.
NOTE:
• Because “module B” interferes with the bracket and cover, cut
the module terminal cover at the position shown in the figure.
JSCIA0148ZZ
JSCIA0155ZZ
JSCIA0191ZZ
JSCIA0192ZZ