Nissan Pathfinder (2006 year). Instruction — part 332
PRECAUTIONS
MTC-9
C
D
E
F
G
H
I
K
L
M
A
B
MTC
2006 Pathfinder
Precautions for Servicing Compressor
EJS004QY
●
Plug all openings to prevent moisture and foreign matter from entering.
●
When the compressor is removed, store it in the same position as it is when mounted on the car.
●
When replacing or repairing compressor, follow “Maintenance of Oil Quantity in Compressor”
exactly. Refer to
MTC-19, "Maintenance of Oil Quantity in Compressor"
●
Keep friction surfaces between clutch and pulley clean. If the surface is contaminated with oil,
wipe it off by using a clean waste cloth moistened with thinner.
●
After compressor service operation, turn the compressor shaft by hand more than 5 turns in both
directions. This will equally distribute oil inside the compressor. After the compressor is installed,
let the engine idle and operate the compressor for 1 hour.
●
After replacing the compressor magnet clutch, apply voltage to the new one and check for normal
operation. Refer to
MTC-102, "Removal and Installation for Compressor Clutch"
Precautions for Service Equipment
EJS004QZ
RECOVERY/RECYCLING EQUIPMENT
Follow the manufacturer's instructions for machine operation and machine maintenance. Never introduce any
refrigerant other than that specified into the machine.
ELECTRONIC LEAK DETECTOR
Follow the manufacturer's instructions for tester operation and tester maintenance.
1.
Plug
2.
O-ring
A.
Torque wrench
B.
Apply oil
C.
Do not apply oil to thread
D.
No good
E.
Good
WJIA1994E
MTC-10
PRECAUTIONS
2006 Pathfinder
VACUUM PUMP
The oil contained inside the vacuum pump is not compatible with the
specified oil for HFC-134a (R-134a) A/C systems. The vent side of
the vacuum pump is exposed to atmospheric pressure so the vac-
uum pump oil may migrate out of the pump into the service hose.
This is possible when the pump is switched off after evacuation (vac-
uuming) and hose is connected to it.
To prevent this migration, use a instruction valve situated near the
hose-to-pump connection, as follows.
●
Usually vacuum pumps have a instruction isolator valve as part of
the pump. Close this valve to isolate the service hose from the
pump.
●
For pumps without an isolator, use a hose equipped with a man-
ual shut-off valve near the pump end. Close the valve to isolate
the hose from the pump.
●
If the hose has an automatic shut off valve, disconnect the hose
from the pump: as long as the hose is connected, the valve is
open and lubricating oil may migrate.
Some one-way valves open when vacuum is applied and close
under a no vacuum condition. Such valves may restrict the pump's
ability to pull a deep vacuum and are not recommended.
MANIFOLD GAUGE SET
Be certain that the gauge face indicates HFC-134a (R-134a). Make
sure the gauge set has 1/2
″
-16 ACME threaded connections for ser-
vice hoses. Confirm the set has been used only with refrigerant
HFC-134a (R-134a) along with specified oil.
SERVICE HOSES
Be certain that the service hoses display the markings described
(colored hose with black stripe). All hoses must include positive shut-
off devices (either instruction or automatic) near the end of the hoses
opposite the manifold gauge.
RHA270D
SHA533D
RHA272D
PRECAUTIONS
MTC-11
C
D
E
F
G
H
I
K
L
M
A
B
MTC
2006 Pathfinder
SERVICE COUPLERS
Never attempt to connect HFC-134a (R-134a) service couplers to a
CFC-12 (R-12) A/C system. The HFC-134a (R-134a) couplers will
not properly connect to the CFC-12 (R-12) system. If an improper
connection is attempted, discharging and contamination may occur.
REFRIGERANT WEIGHT SCALE
Verify that no refrigerant other than HFC134a (R-134a) and specified
oils have been used with the scale. If the scale controls refrigerant
flow electronically, the hose fitting must be 1/2”-16 ACME.
CHARGING CYLINDER
Using a charging cylinder is not recommended. Refrigerant may be vented into air from cylinder's top valve
when filling the cylinder with refrigerant. Also, the accuracy of the cylinder is generally less than that of an
electronic scale or of quality recycle/recharge equipment.
Shut-off valve rotation
A/C service valve
Clockwise
Open
Counterclockwise
Close
RHA273D
RHA274D
MTC-12
PREPARATION
2006 Pathfinder
PREPARATION
PFP:00002
Special Service Tools
EJS004R1
The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.
HFC-134a (R-134a) Service Tools and Equipment
EJS004R2
Never mix HFC-134a (R-134a) refrigerant and/or the specified oil with CFC-12 (R-12) refrigerant and/or the
oil.
Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/oil.
Refrigerant container fittings, service hose fittings and service equipment fittings (equipment which handles
refrigerant and/or oil) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid mixed
use of the refrigerants/oil.
Adapters that convert one size fitting to another must never be used refrigerant/oil contamination will occur
and compressor failure will result.
Tool number
(Kent-Moore No.)
Tool name
Description
—
(J-38873-A)
Pulley installer
Installing pulley
KV99233130
(J-29884)
Pulley puller
Removing pulley
LHA171
LHA172
Tool number
(Kent-Moore No.)
Tool name
Description
HFC-134a (R-134a)
(
—
)
Refrigerant
Container color: Light blue
Container marking: HFC-134a (R-
134a)
Fitting size: Thread size
●
large container 1/2”-16 ACME
—
(
—
)
NISSAN A/C System Oil Type S
Type: Poly alkylene glycol oil (PAG),
type S
Application: HFC-134a (R-134a)
swash plate compressors (NISSAN
only)
Lubricity: 40 m
(1.4 US fl oz, 1.4 Imp
fl oz)
KV991J0130
(ACR2005-NI)
ACR A/C Service Center
Refrigerant Recovery and Recycling
and Recharging
S-NT196
S-NT197
WJIA0293E
PREPARATION
MTC-13
C
D
E
F
G
H
I
K
L
M
A
B
MTC
2006 Pathfinder
—
(J-41995)
Electronic refrigerant leak detector
Power supply:
●
DC 12V (battery terminal)
—
(J-43926)
Refrigerant dye leak detection kit
Kit includes:
(J-42220)
UV lamp and UV safety goggles
(J-41459)
Refrigerant dye injector
(J-41447)
HFC-134a (R-134a) Fluorescent
leak detection dye (box of 24, 1/4
ounce bottles)
(J-43872)
Refrigerant dye cleaner
Power supply:
●
DC 12V (battery terminal)
—
(J-42220)
Fluorescent dye leak detector
Power supply:
●
DC 12V (battery terminal)
For checking refrigerant leak when flu-
orescent dye is installed in A/C system.
Includes: UV lamp and UV safety gog-
gles
—
(J-41447)
HFC-134a (R-134a) Fluorescent
leak detection dye
(box of 24, 1/4 ounce bottles)
Application: For HFC-134a (R-134a)
PAG oil
Container: 1/4 ounce (7.4cc) bottle
(Includes self-adhesive dye identifica-
tion labels for affixing to vehicle after
charging system with dye.)
—
(J-41459)
HFC-134a (R-134a) Refrigerant
dye injector
Use with J-41447, 1/4 ounce bottle
For injecting 1/4 ounce of fluorescent
leak detection dye into A/C system.
—
(J-43872)
Refrigerant dye cleaner
For cleaning dye spills.
Tool number
(Kent-Moore No.)
Tool name
Description
AHA281A
ZHA200H
SHA438F
SHA439F
SHA440F
SHA441F
MTC-14
PREPARATION
2006 Pathfinder
—
(J-39183-C)
Manifold gauge set (with hoses
and couplers)
Identification:
●
The gauge face indicates R-134a.
Fitting size-Thread size
●
1/2”-16 ACME
Service hoses:
●
High side hose
(J-39500-72B)
●
Low side hose
(J-39500-72R)
●
Utility hose
(J-39500-72Y)
Hose color:
●
Low side hose: Blue with black stripe
●
High side hose: Red with black stripe
●
Utility hose: Yellow with black stripe
or green with black stripe
Hose fitting to gauge:
●
1/2”-16 ACME
Service couplers
●
High side coupler
(J-39500-20A)
●
Low side coupler
(J-39500-24A)
Hose fitting to service hose:
●
M14 x 1.5 fitting is optional or perma-
nently attached.
—
(J-39699)
Refrigerant weight scale
For measuring of refrigerant
Fitting size-Thread size
●
1/2”-16 ACME
—
(J-39649)
Vacuum pump
(Including the isolator valve)
Capacity:
●
Air displacement: 4 CFM
●
Micron rating: 20 microns
●
Oil capacity: 482 g (17 oz)
Fitting size-Thread size
●
1/2”-16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
RJIA0196E
S-NT201
S-NT202
S-NT200
S-NT203
PREPARATION
MTC-15
C
D
E
F
G
H
I
K
L
M
A
B
MTC
2006 Pathfinder
Commercial Service Tools
EJS004R3
Tool name
Description
(J-41810-NI)
Refrigerant identifier equipment (R-
134a)
For checking refrigerant purity and
system contamination
Power tool
Loosening bolts and nuts
(J-44614)
Clutch disc holding tool
Clutch disc holding tool
RJIA0197E
PBIC0190E
WHA230
MTC-16
REFRIGERATION SYSTEM
2006 Pathfinder
REFRIGERATION SYSTEM
PFP:KA990
Components
EJS004R4
REFRIGERATION SYSTEM
LJIA0155E