Nissan Versa Note. Instruction — part 619

PCS-86

< DTC/CIRCUIT DIAGNOSIS >

[POWER DISTRIBUTION SYSTEM]

B2615 BLOWER RELAY CIRCUIT

B2615 BLOWER RELAY CIRCUIT

DTC Logic

INFOID:0000000009579014

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PERFORM SELF DIAGNOSTIC RESULT

1. Turn ignition switch to ON, and wait for 1 second or more.

2. Check Self Diagnosis Result of BCM with CONSULT.
Is DTC B2615 detected?

YES

>> Go to

PCS-88, "Diagnosis Procedure"

.

NO

>> Inspection End.

Diagnosis Procedure

INFOID:0000000009579015

Regarding Wiring Diagram information, refer to

PCS-72, "Wiring Diagram"

.

1.

CHECK BLOWER RELAY CONTROL SIGNAL VOLTAGE

1. Remove blower relay.

2. Check voltage between blower relay connector J-1 and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK BLOWER RELAY CONTROL SIGNAL CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect BCM connector M98.

3. Check continuity between BCM connector M98 and blower relay connector J-1.

4. Check continuity between BCM connector M98 and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-70, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

CONSULT Display

DTC Detection Condition

Possible Cause

BLOWER RELAY CIRCUIT
[B2615]

An immediate operation of blower relay is requested
by BCM, but there is no response for more than 1
second.

• Harness or connectors.
• Blower relay.
• Fuse block J/B.
• BCM.

Blower relay

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

J-1

2

Ignition: OFF

0 V

Ignition: ACC or ON

Battery voltage

BCM

Blower relay

Continuity

Connector

Terminal

Connector

Terminal

M98

106

J-1

2

Yes

BCM

Ground

Continuity

Connector

Terminal

M98

106

No

PCS

B2615 BLOWER RELAY CIRCUIT

PCS-87

< DTC/CIRCUIT DIAGNOSIS >

[POWER DISTRIBUTION SYSTEM]

C

D

E

F

G

H

I

J

K

L

B

A

O

P

N

3.

CHECK BLOWER RELAY GROUND CIRCUIT

Check continuity between blower relay connector J-1 and ground.

Is the inspection result normal?

YES

>> Replace blower relay.

NO

>> Repair or replace harness or connectors.

Blower relay

Ground

Continuity

Connector

Terminal

J-1

1

Yes

PCS-88

< DTC/CIRCUIT DIAGNOSIS >

[POWER DISTRIBUTION SYSTEM]

B2616 IGNITION RELAY CIRCUIT

B2616 IGNITION RELAY CIRCUIT

DTC Logic

INFOID:0000000009579017

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PERFORM SELF DIAGNOSTIC RESULT

1. Turn ignition switch to ON, and wait for 1 second or more.

2. Check Self Diagnosis Result of BCM with CONSULT.
Is DTC B2616 detected?

YES

>> Refer to

PCS-88, "Diagnosis Procedure"

.

NO

>> Inspection End.

Diagnosis Procedure

INFOID:0000000009579018

Regarding Wiring Diagram information, refer to

PCS-72, "Wiring Diagram"

.

1.

CHECK IGNITION RELAY-2 CONTROL SIGNAL VOLTAGE

1. Remove ignition relay-2.

2. Check voltage between ignition relay-2 connector J-3 and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK IGNITION RELAY-2 CONTROL SIGNAL CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect BCM connector M98.

3. Check continuity between BCM connector M98 and ignition relay-2 connector J-3.

4. Check continuity between BCM connector M98 and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-70, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

CONSULT Display

DTC Detection Condition

Possible Cause

IGNITION RELAY CIRCUIT
[B2616]

An immediate operation of ignition relay-2 is re-
quested by BCM, but there is no response for more
than 1 second.

• Harness or connectors.
• Ignition relay-2.
• Fuse block J/B.
• BCM.

Ignition relay-2

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

J-3

1

Ignition: OFF

0 V

Ignition: ON

Battery voltage

BCM

Ignition relay-2

Continuity

Connector

Terminal

Connector

Terminal

M98

99

J-3

1

Yes

BCM

Ground

Continuity

Connector

Terminal

M98

99

No

PCS

B2616 IGNITION RELAY CIRCUIT

PCS-89

< DTC/CIRCUIT DIAGNOSIS >

[POWER DISTRIBUTION SYSTEM]

C

D

E

F

G

H

I

J

K

L

B

A

O

P

N

3.

CHECK IGNITION RELAY-2 GROUND CIRCUIT

Check continuity between ignition relay-2 connector J-3 and ground.

Is the inspection result normal?

YES

>> Replace ignition relay-2.

NO

>> Repair or replace harness or connectors.

Ignition relay-2

Ground

Continuity

Connector

Terminal

J-3

2

Yes