Nissan Almera Tino V10. Instruction — part 818
ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) CIRCUIT CHECK
=NLEL0671S07
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check the terminals and connector of ABS actuator and electric unit (control unit) for damage, bend and loose connec-
tion (control unit side and harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect ABS actuator and electric unit (control unit) connector.
2. Check resistance between ABS actuator and electric unit (control unit) harness connector E142 terminals 26 (L) and 15
(R).
YEL454E
OK or NG
OK
©
Replace TCM.
NG
©
I
Repair harness between ABS actuator and electric unit (control unit) and harness con-
nector E125 (LHD models).
I
Repair harness between ABS actuator and electric unit (control unit) and harness con-
nector E145 (RHD models).
CAN SYSTEM (TYPE 5)
Trouble Diagnoses (Cont’d)
EL-568
SMART ENTRANCE CONTROL UNIT CIRCUIT CHECK
=NLEL0671S08
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check the terminals and connector of smart entrance control unit for damage, bend and loose connection (control unit
side and harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect smart entrance control unit connector.
2. Check resistance between smart entrance control unit harness connector M99 terminals 8 (L) and 11 (R).
SEL814Y
OK or NG
OK
©
Replace smart entrance control unit.
NG
©
Repair harness between smart entrance control unit and data link connector.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 5)
Trouble Diagnoses (Cont’d)
EL-569
COMBINATION METER CIRCUIT CHECK
=NLEL0671S09
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side and
harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect combination meter connector.
2. Check resistance between combination meter harness connector M84 terminals 39 (L) and 40 (R).
YEL425E
OK or NG
OK
©
Replace combination meter.
NG
©
Repair harness between combination meter and data link connector.
CAN SYSTEM (TYPE 5)
Trouble Diagnoses (Cont’d)
EL-570
CAN COMMUNICATION CIRCUIT CHECK
=NLEL0671S10
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side,
control unit side, control module side and harness side).
I
Combination meter
I
Smart entrance control unit
I
ECM
I
ABS actuator and electric unit (control unit)
I
Between ECM and data link connector
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect combination meter connector, smart entrance control unit connector and harness connector M82 (LHD mod-
els) or harness connector M80 (RHD models).
2. Check continuity between data link connector M6 terminals 6 (L) and 3 (R).
SEL816Y
OK or NG
OK
©
GO TO 3.
NG
©
I
Repair harness between data link connector and harness connector M82 (LHD mod-
els).
I
Repair harness between data link connector and harness connector M80 (RHD mod-
els).
I
Repair harness between data link connector and smart entrance control unit.
I
Repair harness between data link connector and combination meter.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 5)
Trouble Diagnoses (Cont’d)
EL-571