Nissan Almera Tino V10. Instruction — part 751
PRELIMINARY CHECK
=NLEL0573S03
First perform the “SELF-DIAG RESULTS” in “SMART ENTRANCE”
with CONSULT-II, when perform the each trouble diagnosis. Refer
to EL-298, “CONSULT-II INSPECTION PROCEDURE”.
SIIA1601E
After performing preliminary check, go to SYMPTOM CHART.
Before starting trouble diagnoses below, perform preliminary
check.
Symptom numbers in the symptom chart correspond with those of
Preliminary check.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis (Cont’d)
EL-300
SYMPTOM CHART
NLEL0573S04
Symptom
Malfunctioning system
Reference
page
SYMPTOM 1
Power door lock does not operate using any switch
Power supply and ground circuit check
Door lock actuator check
If above systems are OK, replace smart entrance con-
trol unit.
—
SYMPTOM 2
Power door lock does not operate with lock/unlock
switch.
Door lock/unlock switch check
If above system is OK, replace smart entrance control
unit.
—
SYMPTOM 3
Specific door lock actuator does not operate.
Door lock actuator check
If above system is OK, replace smart entrance control
unit.
—
SYMPTOM 4
Super lock cannot be set by door key cylinder.
Super lock actuator check
Key switch check
Ignition switch ON circuit check
If above systems are OK, replace smart entrance con-
trol unit.
—
SYMPTOM 5
*Super lock cannot be released by door key cylinder.
Super lock actuator check
If above systems are OK, replace smart entrance con-
trol unit.
—
SYMPTOM 6
*Super lock cannot be released by ignition key switch.
Super lock actuator check
Ignition switch “ON” circuit check
If above systems are OK, replace smart entrance con-
trol unit.
—
SYMPTOM 7
Specific super lock actuator does not operate.
Super lock actuator check
If above system is OK, replace smart entrance control
unit.
—
SYMPTOM 8
*Key reminder system does not operate.
Door switch check
Trunk room lamp switch or back door switch check
—
Key switch check
If above system is OK, replace smart entrance control
unit.
—
*: Make sure the power door lock system operates properly.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis (Cont’d)
EL-301
POWER SUPPLY AND GROUND CIRCUIT CHECK
NLEL0573S05
1
CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect smart entrance control unit connector.
3. Check voltage between smart entrance control unit harness connector M101 terminal 49 (W/L), 56 (R/B) and ground.
SIIA1564E
MTBL1480
OK or NG
OK
©
GO TO 2.
NG
©
Check smart entrance control unit power supply circuit for open or short.
2
CHECK GROUND CIRCUIT
Check continuity between smart entrance control unit harness connector M195 terminal 53 (B) and ground.
SIIA1565E
MTBL1481
OK or NG
OK
©
Power supply and ground circuit is OK.
NG
©
Check smart entrance control unit ground circuit for open or short.
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis (Cont’d)
EL-302
IGNITION SWITCH “ON” CIRCUIT CHECK
NLEL0573S06
1
CHECK IGNITION ON SIGNAL
1. Disconnect smart entrance control unit connector.
2. Check voltage between smart entrance control unit harness connector M100 terminal 29 (Y/G) and ground.
SIIA1602E
MTBL1553
OK or NG
OK
©
Ignition ON signal is OK.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis (Cont’d)
EL-303
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.