Nissan Almera Tino V10. Instruction — part 808
SMART ENTRANCE CONTROL UNIT CIRCUIT CHECK
=NLEL0651S09
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check the terminals and connector of smart entrance control unit for damage, bend and loose connection (control unit
side and harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect smart entrance control unit connector.
2. Check resistance between smart entrance control unit harness connector M99 terminals 8 (L) and 11 (R).
SEL814Y
OK or NG
OK
©
Replace smart entrance control unit.
NG
©
Repair harness between smart entrance control unit and data link connector.
CAN SYSTEM (TYPE 3)
Trouble Diagnoses (Cont’d)
EL-528
COMBINATION METER CIRCUIT CHECK
=NLEL0651S11
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side and
harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect combination meter connector.
2. Check resistance between combination meter harness connector M84 terminals 39 (L) and 40 (R).
YEL425E
OK or NG
OK
©
Replace combination meter.
NG
©
Repair harness between combination meter and data link connector.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 3)
Trouble Diagnoses (Cont’d)
EL-529
CAN COMMUNICATION CIRCUIT CHECK
=NLEL0651S12
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side,
control unit side, control module side and harness side).
I
Combination meter
I
Smart entrance control unit
I
ECM
I
ABS actuator and electric unit (control unit)
I
Steering angle sensor
I
Between ECM and data link connector
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect combination meter connector, smart entrance control unit connector, and harness connector M82 (LHD
models) or harness connector M80 (RHD models).
2. Check continuity between data link connector M6 terminals 6 (L) and 3 (R).
SEL816Y
OK or NG
OK
©
GO TO 3.
NG
©
I
Repair harness between data link connector and harness connector M82 (LHD mod-
els).
I
Repair harness between data link connector and harness connector M80 (RHD mod-
els).
I
Repair harness between data link connector and smart entrance control unit.
I
Repair harness between data link connector and combination meter.
CAN SYSTEM (TYPE 3)
Trouble Diagnoses (Cont’d)
EL-530
3
CHECK HARNESS FOR SHORT CIRCUIT
Check continuity between data link connector M29 terminals 6 (L), 3 (R) and ground.
SEL817Y
OK or NG
OK
©
GO TO 4.
NG
©
I
Repair harness between data link connector and harness connector M82 (LHD mod-
els).
I
Repair harness between data link connector and harness connector M80 (RHD mod-
els).
I
Repair harness between data link connector and smart entrance control unit.
I
Repair harness between data link connector and combination meter.
4
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect ECM connector and harness connector M11 (LHD models).
2. Check continuity between ECM harness connector M107 terminals 95 (L) and 87 (R).
YEL439E
OK or NG
OK
©
GO TO 5.
NG
©
I
Repair harness between ECM and harness connector M11 (LHD models).
I
Repair harness between ECM and harness connector M80 (RHD models).
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 3)
Trouble Diagnoses (Cont’d)
EL-531