Nissan Murano. Instruction — part 870
HAC-254
< PRECAUTION >
[WITH 7 INCH DISPLAY]
FLUORESCENT LEAK DETECTOR
FLUORESCENT LEAK DETECTOR
General Precautions
INFOID:0000000009722229
CAUTION:
• The A/C system contains a fluorescent leak detection dye used for locating refrigerant leakages. An
ultraviolet (UV) lamp is required to illuminate the dye when inspecting for leakages.
• Always wear fluorescence enhancing UV safety goggles to protect eyes and enhance the visibility of
the fluorescent dye.
• The fluorescent dye leak detector is not a replacement for an electrical leak detector (SST: J-41995).
The fluorescent dye leak detector should be used in conjunction with an electrical leak detector
(SST: J-41995) to pin-point refrigerant leakages.
• Read and follow all manufacture operating instructions and precautions prior to performing the work
for the purpose of safety and customer satisfaction.
• A compressor shaft seal should not necessarily be repaired because of dye seepage. The compres-
sor shaft seal should only be repaired after confirming the leakage with an electrical leak detector
(SST: J-41995).
• Always remove any remaining dye from the leakage area after repairs are completed to avoid a mis-
diagnosis during future service.
• Never allow dye to come into contact with painted body panels or interior components. Clean imme-
diately with the approved dye cleaner if dye is spilled. Fluorescent dye left on a surface for an
extended period of time cannot be removed.
• Never spray the fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).
• Never use more than one refrigerant dye bottle (1/4 ounce /7.4 cc) per A/C system.
• Leak detection dyes for HFC-134a (R-134a) and CFC-12 (R-12) A/C systems are different. Never use
HFC-134a (R-134a) leak detection dye in CFC-12 (R-12) A/C system, or CFC-12 (R-12) leak detection
dye in HFC-134a (R-134a) A/C system, or A/C system damage may result.
• The fluorescent properties of the dye remains for three or more years unless a compressor malfunc-
tion occurs.
IDENTIFICATION
NOTE:
Vehicles with factory installed fluorescent dye have a green label.
Vehicles without factory installed fluorescent dye have a blue label.
IDENTIFICATION LABEL FOR VEHICLE
Vehicles with factory installed fluorescent dye have an identification label on the front side of hood.
HRN-1
DRIVER CONTROLS
C
D
E
F
G
H
I
J
K
M
SECTION
HRN
A
B
HRN
N
O
P
CONTENTS
HORN
DTC/CIRCUIT DIAGNOSIS . . . . . . ..
HORN . . . . . . . . . . . . . . . . ..
Wiring Diagram - HORN - . . . . . . . . . .....
PRECAUTION . . . . . . . . . . . ...
PRECAUTIONS . . . . . . . . . . . . ...
FOR USA AND CANADA . . . . . . . . . . ....
FOR USA AND CANADA : Precautions for Re-
moving of Battery Terminal . . . . . . . . . ...
FOR MEXICO . . . . . . . . . . . . . . . ..
FOR MEXICO : Precautions for Removing of Bat-
tery Terminal . . . . . . . . . . . . . . . .
REMOVAL AND INSTALLATION . . . .
HORN . . . . . . . . . . . . . . . . .
Exploded View . . . . . . . . . . . . . . ..
HRN-2
< DTC/CIRCUIT DIAGNOSIS >
HORN
DTC/CIRCUIT DIAGNOSIS
HORN
Wiring Diagram - HORN -
INFOID:0000000009718821
JCLWM2824GB
HORN
HRN-3
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
M
A
B
HRN
N
O
P
JRLWC9489GB
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.