Nissan GT-R. Instruction — part 245

PWC-30

< DTC/CIRCUIT DIAGNOSIS >

DOOR SWITCH CIRCUIT

3.

Check continuity between malfunctioning power window motor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK INTERMITTENT INCIDENT

Refer to

GI-38, "Intermittent Incident"

.

>> INSPECTION END

Power window motor

BCM

Continuity

Connector

Terminal

Connector

Terminal

Driver side

D10

6

M123

150

Existed

Passenger side

D40

124

Power window motor

Ground

Continuity

Connector

Terminal

Driver side

D10

6

Not existed

Passenger side

D40

POWER WINDOW MOTOR

PWC-31

< ECU DIAGNOSIS INFORMATION >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

ECU DIAGNOSIS INFORMATION

POWER WINDOW MOTOR

Wiring Diagram - POWER WINDOW SYSTEM -

INFOID:0000000009159949

For connector terminal arrangements, harness layouts, and alphabets in a

(option abbreviation; if not

described in wiring diagram), refer to

GI-12, "Connector Information"

.

JCKWA1313GB

PWC-32

< ECU DIAGNOSIS INFORMATION >

POWER WINDOW MOTOR

Fail-Safe

INFOID:0000000009159950

FAIL-SAFE CONTROL

Fail-safe control is activated when the actual glass position that is out of the specified value is detected com-
pared to the fully closed position memorized in module in power window motor, or when a malfunction is
detected in the encoder signal that indicates UP or DOWN speed and direction of door glass.

In fail-safe control, the system changes to a non-initialized condition and the following functions do not oper-
ate.
• AUTO UP operation
• Anti-pinch function
• Timer function
• Automatic window adjusting function
When fail-safe control is activated, perform initializing operation to recover. If a malfunction is detected in
power window motor, fail-safe control is activated again.

Malfunction

Malfunction condition

Pulse direction malfunc-
tion (opposite backlash
pulse detection)

When a pulse signal indicates that the window is moving in the opposite direction against the power
window motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.

Pulse sensor (Hall IC)
malfunction (one side
pulse shut-off detection)

When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.

Both pulse sensor mal-
function (both sides pulse
shut-off detection)

When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.

Glass recognition position
malfunction 1 (UP over-
run)

When the actual door glass position that is out of the specified value is detected compared to the
door glass fully closed position memorized in module, while door glass is being operated UP. (Actual
door glass fully closed position is detected to be higher than the memorized position in module for
the specified value or more.)

Glass recognition position
malfunction 2 (Out of
memorized area)

When the actual door glass position that is out of the specified value is detected compared to the
door glass fully closed position memorized in module, while door glass is being operated UP. (Actual
door glass fully closed position is detected to be lower than the memorized position in module for the
specified value or more.)

Glass recognition position
malfunction 3 (Full stroke
malfunction)

When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP.

Fully closed position up-
date malfunction

When door glass is continuously operated UP and DOWN for the specified value or more without
fully closing door glass.

NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY SWITCH

PWC-33

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

SYMPTOM DIAGNOSIS

NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY
SWITCH

Diagnosis Procedure

INFOID:0000000009159951

1.

CHECK BCM POWER SUPPLY AND GROUND CIRCUIT

Check BCM power supply and ground circuit.
Refer to

BCS-13, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CHECK POWER WINDOW MOTOR POWER SUPPLY AND GROUND CIRCUIT

Check power window motor power supply and ground circuit.
Refer to

PWC-10, "POWER WINDOW MOTOR : Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT

Check power window main switch power supply and ground circuit.
Refer to

PWC-11, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace the malfunctioning parts.

4.

CONFIRM THE OPERATION

Confirm the operation again.
Is the inspection result normal?

YES

>> Check intermittent incident. Refer to

GI-38, "Intermittent Incident"

.

NO

>> GO TO 1.

Была ли эта страница вам полезна?
Да!Нет
9 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности