Nissan GT-R. Instruction — part 245
PWC-30
< DTC/CIRCUIT DIAGNOSIS >
DOOR SWITCH CIRCUIT
3.
Check continuity between malfunctioning power window motor harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK INTERMITTENT INCIDENT
GI-38, "Intermittent Incident"
>> INSPECTION END
Power window motor
BCM
Continuity
Connector
Terminal
Connector
Terminal
Driver side
D10
6
M123
150
Existed
Passenger side
D40
124
Power window motor
Ground
Continuity
Connector
Terminal
Driver side
D10
6
Not existed
Passenger side
D40
POWER WINDOW MOTOR
PWC-31
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
ECU DIAGNOSIS INFORMATION
POWER WINDOW MOTOR
Wiring Diagram - POWER WINDOW SYSTEM -
INFOID:0000000009159949
For connector terminal arrangements, harness layouts, and alphabets in a
(option abbreviation; if not
described in wiring diagram), refer to
GI-12, "Connector Information"
JCKWA1313GB
PWC-32
< ECU DIAGNOSIS INFORMATION >
POWER WINDOW MOTOR
Fail-Safe
INFOID:0000000009159950
FAIL-SAFE CONTROL
Fail-safe control is activated when the actual glass position that is out of the specified value is detected com-
pared to the fully closed position memorized in module in power window motor, or when a malfunction is
detected in the encoder signal that indicates UP or DOWN speed and direction of door glass.
In fail-safe control, the system changes to a non-initialized condition and the following functions do not oper-
ate.
• AUTO UP operation
• Anti-pinch function
• Timer function
• Automatic window adjusting function
When fail-safe control is activated, perform initializing operation to recover. If a malfunction is detected in
power window motor, fail-safe control is activated again.
Malfunction
Malfunction condition
Pulse direction malfunc-
tion (opposite backlash
pulse detection)
When a pulse signal indicates that the window is moving in the opposite direction against the power
window motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Pulse sensor (Hall IC)
malfunction (one side
pulse shut-off detection)
When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensor mal-
function (both sides pulse
shut-off detection)
When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Glass recognition position
malfunction 1 (UP over-
run)
When the actual door glass position that is out of the specified value is detected compared to the
door glass fully closed position memorized in module, while door glass is being operated UP. (Actual
door glass fully closed position is detected to be higher than the memorized position in module for
the specified value or more.)
Glass recognition position
malfunction 2 (Out of
memorized area)
When the actual door glass position that is out of the specified value is detected compared to the
door glass fully closed position memorized in module, while door glass is being operated UP. (Actual
door glass fully closed position is detected to be lower than the memorized position in module for the
specified value or more.)
Glass recognition position
malfunction 3 (Full stroke
malfunction)
When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP.
Fully closed position up-
date malfunction
When door glass is continuously operated UP and DOWN for the specified value or more without
fully closing door glass.
NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY SWITCH
PWC-33
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
SYMPTOM DIAGNOSIS
NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY
SWITCH
Diagnosis Procedure
INFOID:0000000009159951
1.
CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
Refer to
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK POWER WINDOW MOTOR POWER SUPPLY AND GROUND CIRCUIT
Check power window motor power supply and ground circuit.
Refer to
PWC-10, "POWER WINDOW MOTOR : Diagnosis Procedure"
.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT
Check power window main switch power supply and ground circuit.
Refer to
PWC-11, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the malfunctioning parts.
4.
CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.