P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Component Description
INFOID:0000000009886727
The EVAP control system pressure sensor (2) detects pressure in the purge line. The sensor output voltage to
the ECM increases as pressure increases.
On Board Diagnosis Logic
INFOID:0000000009886728
NOTE:
If DTC P0452 is displayed with DTC P0643, first perform the trouble diagnosis for DTC P0643. Refer to
.
DTC Confirmation Procedure
INFOID:0000000009886729
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next step.
1. Turn ignition swich OFF and wait at least 10 seconds.
2. Turn ignition swich ON.
3. Turn ignition swich OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41°F) or more.
WITH CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT.
1
: Drain filter
3
: EVAP canister
4
: EVAP canister vent control value
ALBIA0401ZZ
PBIB1207E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0452
0452
EVAP control system pressure
sensor low input
An excessively low voltage from the sen-
sor is sent to ECM.
• Harness or connectors
(The sensor circuit is open or shorted.)
• EVAP control system pressure sensor
EC-318
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
5. Make sure that “FUEL T/TMP SE” is more than 0
°C (32°F).
6. Start engine and wait at least 20 seconds.
7. Check 1st trip DTC.
8. If 1st trip DTC is detected, go to
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Check that voltage between ECM terminal 107 (Fuel tank tem-
perature sensor signal) and ground is less than 4.2V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select Service $07 with GST.
If 1st trip DTC is detected, go to
.
Diagnosis Procedure
INFOID:0000000009886730
1.
CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace ground connections.
2.
CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor (2) harness
connector.
2. Check sensor harness connector for water.
OK or NG
PBIB1110E
BBIA0354E
1
: Drain filter
3
: EVAP canister
4
: EVAP canister vent control value
ALBIA0401ZZ
Water should not exist.
P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-319
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
OK
>> GO TO 3.
NG
>> Repair or replace harness connector.
3.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between EVAP control system pressure sensor
terminal 3 and ground with CONSULT or tester.
OK or NG
OK
>> GO TO 5.
NG
>> GO TO 4.
4.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors C1, E41
• Harness connectors E5, F14
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal
67.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 6.
6.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors C1, E41
• Harness connectors E5, F14
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal
2.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 9.
NG
>> GO TO 8.
Voltage: Approximately 5V
PBIB0138E
Continuity should exist.
Continuity should exist.
EC-320
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
8.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors C1, E41
• Harness connectors E5, F14
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
9.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-320, "Component Inspection"
OK or NG
OK
>> GO TO 10.
NG
>> Replace EVAP control system pressure sensor.
10.
CHECK INTERMITTENT INCIDENT
GI-39, "How to Check Terminal"
and
GI-42, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000009886731
EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.
3. Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.
CAUTION:
• Always calibrate the vacuum pump gauge when using it.
• Do not apply below -93.3 kPa (-700 mmHg, -27.56 inHg) or
pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.
Applied vacuum [kPa
(mmHg, inHg)]
Voltage (V)
Not applied
1.8 - 4.8
-26.7 (-200, -7.87)
2.1 to 2.5 lower than above value
PBIB1173E