Nissan Qashqai (2007-2010). Manual — part 1867
PG-6
< BASIC INSPECTION >
[POWER SUPPLY & GROUND CIRCUIT]
BATTERY
YES
>> GO TO 2.
NO
>> Replace battery.
2.
CHECKING SPECIFIC GRAVITY
Check specific gravity. Refer to
.
Inspection results
Above 1.220 (Test using battery checker)>>GO TO 3.
Above 1.220 (Test using load tester)>>GO TO 5.
1.100 - 1.220 (When performing quick charge)>>GO TO 7.
1.100 - 1.220 (When performing standard charge)>>GO TO 12.
Below 1.100>>GO TO 13.
3.
CAPACITY TEST
Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?
YES
>> Ready for use. Mount battery again and check loose terminals. Also check other related circuits.
NO
>> GO TO 4.
4.
QUICK CHARGE
1.
Perform quick charge. Time required: 45 min. Refer to
2.
Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?
YES
>> Ready for use.
NO
>> Replace battery.
5.
CAPACITY TEST
1.
Test using load tester.
2.
Check battery type and determine the specified current using the table.
Discharging Current (Load Tester)
Type
Current (A)
28B19R(L)
90
34B19R(L)
99
46B24R(L)
135
55B24R(L)
50D23R(L)
150
55D23R(L)
180
80D23R(L)
195
65D26R(L)
80D26R(L)
75D31R(L)
210
95D31R(L)
240
115D31R(L)
025 [YUASA type code]
027 [YUASA type code]
285
110D26R(L)
300
95E41R(L)
067 [YUASA type code]
325
130E41R(L)
330
096 [YUASA type code]
375
LB1 (330)
—
LB1+ (420)
—
PG
BATTERY
PG-7
< BASIC INSPECTION >
[POWER SUPPLY & GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
3.
Read load tester voltage when specified discharging current flows through battery for 15 seconds.
Is the voltage 9.6 V or more?
YES
>> Ready for use.
NO
>> GO TO 6.
6.
QUICK CHARGE
1.
Perform quick charge. Time required: 45 min. Refer to
2.
Test using load tester.
Is the voltage 9.6 V or more?
YES
>> Ready for use.
NO
>> Replace battery.
7.
QUICK CHARGE
1.
Perform quick charge. Refer to
2.
Perform capacity test.
Test using battery checker.>>GO TO 8.
Test using load tester.>>GO TO 10.
8.
CAPACITY TEST
Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?
YES
>> Ready for use.
NO
>> GO TO 9.
9.
CHECKING SPECIFIC GRAVITY
1.
Check specific gravity. Refer to
.
2.
Perform recharge. Refer to
NOTE:
If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tempera-
ture is below 55
°
C (131
°
F).
3.
Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?
YES
>> Ready for use.
NO
>> Replace battery.
10.
CAPACITY TEST
1.
Test using load tester.
2.
Check battery type and determine the specified current using the table.
Discharging Current (Load Tester)
LB2 (510)
—
LB2+ (600)
—
LB3 (720)
—
L3 (720)
—
Type
Current (A)
Type
Current (A)
28B19R(L)
90
34B19R(L)
99
46B24R(L)
135
55B24R(L)
50D23R(L)
150
55D23R(L)
180
PG-8
< BASIC INSPECTION >
[POWER SUPPLY & GROUND CIRCUIT]
BATTERY
3.
Read load tester voltage when specified discharging current flows through battery for 15 seconds.
Is the voltage 9.6 V or more?
YES
>> Ready for use.
NO
>> GO TO 11.
11.
CHECKING SPECIFIC GRAVITY
1.
Check specific gravity. Refer to
.
2.
Perform recharge. Refer to
NOTE:
If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tempera-
ture is below 55
°
C (131
°
F).
3.
Test using load tester.
Is the voltage 9.6 V or more?
YES
>> Ready for use.
NO
>> Replace battery.
12.
STANDARD CHARGE
NOTE:
“STANDARD CHARGE” is recommended if the vehicle is in storage after charging.
1.
Perform standard charge. Refer to
2.
Perform capacity test.
Test using battery checker.>>GO TO 14.
Test using load tester.>>GO TO 15.
13.
SLOW CHARGE
1.
Perform slow charge. Refer to
2.
Perform capacity test.
Test using battery checker.>>GO TO 14.
Test using load tester.>>GO TO 15.
80D23R(L)
195
65D26R(L)
80D26R(L)
75D31R(L)
210
95D31R(L)
240
115D31R(L)
025 [YUASA type code]
027 [YUASA type code]
285
110D26R(L)
300
95E41R(L)
067 [YUASA type code]
325
130E41R(L)
330
096 [YUASA type code]
375
LB1 (330)
—
LB1+ (420)
—
LB2 (510)
—
LB2+ (600)
—
LB3 (720)
—
L3 (720)
—
Type
Current (A)
PG
BATTERY
PG-9
< BASIC INSPECTION >
[POWER SUPPLY & GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
14.
CAPACITY TEST
Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?
YES
>> Ready for use.
NO
>> Replace battery.
15.
CAPACITY TEST
1.
Test using load tester.
2.
Check battery type and determine the specified current using the table.
Discharging Current (Load Tester)
3.
Read load tester voltage when specified discharging current flows through battery for 15 seconds.
Is the voltage 9.6 V or more?
YES
>> Ready for use.
NO
>> Replace battery.
Type
Current (A)
28B19R(L)
90
34B19R(L)
99
46B24R(L)
135
55B24R(L)
50D23R(L)
150
55D23R(L)
180
80D23R(L)
195
65D26R(L)
80D26R(L)
75D31R(L)
210
95D31R(L)
240
115D31R(L)
025 [YUASA type code]
027 [YUASA type code]
285
110D26R(L)
300
95E41R(L)
067 [YUASA type code]
325
130E41R(L)
330
096 [YUASA type code]
375
LB1 (330)
—
LB1+ (420)
—
LB2 (510)
—
LB2+ (600)
—
LB3 (720)
—
L3 (720)
—