Nissan Qashqai (2007-2010). Manual — part 737

BRC-146

< COMPONENT DIAGNOSIS >

[ESP/TCS/ABS]

PARKING BRAKE SWITCH

3.

Check continuity between parking brake switch terminal and ground.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace parking brake switch.

Parking brake switch

Condition

Continuity

Connector

Terminal

M103

1

Ground

When the parking brake switch is operated.

Existed

When the parking brake switch is not operated.

Not existed

ESP OFF SWITCH

BRC-147

< COMPONENT DIAGNOSIS >

[ESP/TCS/ABS]

C

D

E

G

H

I

J

K

L

M

A

B

BRC

N

O

P

ESP OFF SWITCH

Description

INFOID:0000000000924900

ESP OFF switch can deactivate (turn OFF) the ESP/TCS function by pressing the ESP OFF switch.

Component Function Check

INFOID:0000000000924901

1.

CHECK ESP OFF SWITCH OPERATION

Turn ON/OFF the ESP OFF switch and check that the ESP OFF indicator lamp in the combination meter turns
ON/OFF correctly.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Go to diagnosis procedure. Refer to

BRC-147, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000000924902

1.

CHECK ESP OFF SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect ESP OFF switch connector.

3.

Check continuity between ESP OFF switch connector terminals.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> ESP OFF switch is malfunctioning. Replace ESP OFF switch.

2.

CHECK ESP OFF SWITCH HARNESS

1.

Disconnect ABS actuator and electric unit (control unit) connector.

2.

Check continuity between ESP OFF switch connector terminals and ABS actuator and electric unit (con-
trol unit) connector terminal and/or ground.

Is the inspection result normal?

Condition

ESP OFF indicator lamp illumination status

ESP OFF switch: ON

ON

ESP OFF switch: OFF

OFF

ESP OFF switch

Condition

Continuity

Connector

Terminal

M5

1

2

When ESP OFF switch is hold pressed.

Existed

When releasing ESP OFF switch.

Not existed

ABS actuator and electric unit

(control unit)

ESP OFF switch

Continuity

Connector

Terminal

Connector

Terminal

E36

21

M5

1

Existed

ABS actuator and electric unit (control unit)

Continuity

Connector

Terminal

E36

21

Ground

Not existed

ESP OFF switch

Continuity

Connector

Terminal

M5

2

Ground

Existed

BRC-148

< COMPONENT DIAGNOSIS >

[ESP/TCS/ABS]

ESP OFF SWITCH

YES

>> GO TO 3.

NO

>> If the open or short in harness, repair or replace harness.

3.

CHECK COMBINATION METER

Check if the indication and operation of combination meter are normal. Refer to

MWI-21, "Diagnosis Descrip-

tion"

.

Is the inspection result normal?

YES

>> Replace ABS actuator and electric unit (control unit).

NO

>> Repair or replace combination meter.

Component Inspection

INFOID:0000000000924903

INSPECTION PROCEDURE

1.

CHECK ESP OFF SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect ESP OFF switch connector.

3.

Check continuity between ESP OFF switch connector terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace ESP OFF switch.

ESP OFF switch

Condition

Continuity

Connector

Terminal

M5

1

2

When ESP OFF switch is hold pressed.

Existed

When releasing ESP OFF switch.

Not existed

ABS WARNING LAMP

BRC-149

< COMPONENT DIAGNOSIS >

[ESP/TCS/ABS]

C

D

E

G

H

I

J

K

L

M

A

B

BRC

N

O

P

ABS WARNING LAMP

Description

INFOID:0000000000924904

×

: ON –: OFF

Component Function Check

INFOID:0000000000924905

1.

CHECK ABS WARNING LAMP OPERATION

Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.
Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Go to diagnosis procedure. Refer to

BRC-149, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000000924906

1.

CHECK SELF-DIAGNOSIS

Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to

BRC-96, "CONSULT-III Function

(ABS)"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Check items displayed by self-diagnosis.

2.

CHECK COMBINATION METER

Check if the indication and operation of combination meter are normal. Refer to

MWI-21, "Diagnosis Descrip-

tion"

.

Is the inspection result normal?

YES

>> Replace ABS actuator and electric unit (control unit).

NO

>> Repair or replace combination meter.

Condition

ABS warning lamp

Ignition switch OFF

For 1 second after turning ON ignition switch

×

1 second later after turning ON ignition switch

ABS function is malfunctioning.

×

EBD function is malfunctioning.

×