Nissan Tiida C11. Instruction — part 1123
PWC-28
< COMPONENT DIAGNOSIS >
POWER WINDOW MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect rear power window switch RH.
3.
Check continuity between rear power window switch RH con-
nector (A) and rear power window motor RH connector (B).
4.
Check continuity between rear power window switch RH con-
nector (A) and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK REAR POWER WINDOW MOTOR RH
Check rear power window motor RH.
Refer to
PWC-28, "REAR RH : Component Inspection"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-55, "Intermittent Incident"
.
NO
>> Replace rear power window motor RH. Refer to
GW-21, "Removal and Installation"
.
REAR RH : Component Inspection
INFOID:0000000001696332
COMPONENT INSPECTION
1.
CHECK REAR POWER WINDOW MOTOR RH
Does motor operate by connecting the battery voltage directly to rear power window motor RH?
Is the inspection result normal?
YES
>> Power window motor is OK.
NO
>> Replace rear power window motor RH. Refer to
GW-21, "Removal and Installation"
.
Rear power window
switch RH connector
Terminal
Rear power window
motor RH connector
Terminal
Continuity
D303 (A)
5
D304 (B)
2
Yes
4
1
Rear power window switch
RH connector
Terminal
Ground
Continuity
D303 (A)
5
No
4
PIIB6432E
Terminal
Motor condition
(+)
(–)
2
1
DOWN
1
2
UP
ENCODER
PWC-29
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
ENCODER
DRIVER SIDE
DRIVER SIDE : Description
INFOID:0000000001696333
Detects condition of the front power window motor (driver side) operation and transmits to main power window
and door lock/unlock switch as pulse signal.
DRIVER SIDE : Component Function Check
INFOID:0000000001696334
1.
CHECK ENCODER OPERATION
Does front door motor (driver side) perform AUTO open/close operation normally with main power window and
door lock/unlock switch?
Is the inspection result normal?
YES
>> Encoder operation is OK.
NO
>> Refer to
PWC-29, "DRIVER SIDE : Diagnosis Procedure"
DRIVER SIDE : Diagnosis Procedure
INFOID:0000000001696335
Encoder Circuit Check
1.
CHECK ENCODER OPERATION
1.
Connect front power window motor (driver side).
2.
Turn ignition switch ON.
3.
Check signal between main power window and door lock/unlock
switch connector and ground with oscilloscope.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-55, "Intermittent Incident"
.
NO
>> GO TO 2
2.
CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) POWER SUPPLY
Terminals
Signal
(Reference value)
(+)
(–)
Main power window
and door lock/unlock
switch
connector
Terminal
D7
9
Ground
Refer to following signal
13
ALKIA0295ZZ
JMKIA0220GB
PWC-30
< COMPONENT DIAGNOSIS >
ENCODER
1.
Turn ignition switch ON.
2.
Check voltage between front power window motor (driver side)
connector and ground.
Is the measurement value within the specification?
YES
>> GO TO 4
NO
>> GO TO 3
3.
CHECK HARNESS CONTINUITY 1
1.
Turn ignition switch OFF.
2.
Disconnect main power window and door lock/unlock switch and
front power window motor (driver side).
3.
Check continuity between main power window and door lock/
unlock switch connector (A) and front power window motor
(driver side) connector (B).
4.
Check continuity between main power window and door lock/unlock switch connector (A) and ground.
Is the inspection result normal?
YES
>> Replace main power window and door lock/unlock switch. Refer to
INT-13, "Removal and Installa-
. After that, refer to
PWC-31, "DRIVER SIDE : Special Repair Requirement"
.
NO
>> Repair or replace harness.
4.
CHECK GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect front power window motor (driver side).
3.
Check continuity between front power window motor (driver
side) connector and ground.
Is the inspection result normal?
YES
>> GO TO 6
NO
>> GO TO 5
5.
CHECK HARNESS CONTINUITY 2
Terminal
Voltage (V)
(Approx.)
(+)
(–)
Front power window motor
(driver side) connector
Terminal
D9
1
Ground
10
PIIB6433E
Main power window
and door lock/unlock
switch connector
Terminal
Front power window
motor (driver side)
connector
Terminal
Continuity
D7 (A)
15
D9 (B)
1
Yes
Main power window and door
lock/unlock switch connector
Terminal
Ground
Continuity
D7 (A)
15
No
PIIB6434E
Front power window motor
(driver side) connector
Terminal
Ground
Continuity
D9
6
Yes
LIIA0923E
ENCODER
PWC-31
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
1.
Disconnect main power window and door lock/unlock switch.
2.
Check continuity between main power window and door lock/
unlock switch connector (A) and front power window motor
(driver side) connector (B).
Is the inspection result normal?
YES
>> Replace main power window and door lock/unlock
switch. Refer to
INT-13, "Removal and Installation"
. After that, refer to
.
NO
>> Repair or replace harness.
6.
CHECK HARNESS CONTINUITY 3
1.
Disconnect main power window and door lock/unlock switch.
2.
Check continuity between main power window and door lock/
unlock switch connector (A) and front power window motor
(driver side) connector (B).
3.
Check continuity between main power window and door lock/unlock switch connector (A) and ground.
Is the inspection result normal?
YES
>> Replace front power window motor (driver side). Refer to
GW-14, "Removal and Installation"
.
After that, refer to
PWC-23, "DRIVER SIDE : Special Repair Requirement"
NO
>> Repair or replace harness.
DRIVER SIDE : Special Repair Requirement
INFOID:0000000001696336
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Refer to
PWC-4, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Check intermittent incident. Refer to
GI-55, "Intermittent Incident"
.
Main power window
and door lock/unlock
switch connector
Terminal
Front power window
motor LH connector
Terminal
Continuity
D7 (A)
2
D9 (B)
6
Yes
WIIA0511E
Main power window and
door lock/unlock switch
connector
Terminal
Front power win-
dow motor (driv-
er side)
connector
Terminal
Continuity
D7 (A)
9
D9 (B)
5
Yes
13
4
Main power window and
door lock/unlock switch
connector
Terminal
Ground
Continuity
D7 (A)
9
No
13
PIIB6437E