Nissan Tiida C11. Instruction — part 1249
DTC P0705 PARK/NEUTRAL POSITION (PNP) SWITCH
TM-47
< COMPONENT DIAGNOSIS >
[TYPE 1 (4AT: RE4F03B)]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
1.
Check continuity between PNP switch harness connector termi-
nals.
2.
If NG, check again with control cable (2) disconnected from
instruction shaft of A/T assembly. Refer to step 1.
(1): Lock nut
(3): Instruction shaft
3.
If OK on step 2, adjust control cable (2). Refer to
.
4.
If NG on step 2, remove PNP switch from A/T and check conti-
nuity of PNP switch terminals. Refer to step 1.
5.
If OK on step 4, adjust PNP switch. Refer to
.
6.
If NG on step 4, replace PNP switch. Refer to
Neutral Position (PNP) Switch"
.
Selector lever position
Connector
Terminal
Continuity
“P”
F25
1 - 2, 3 - 7
Yes
*Continuity
should not
exist in posi-
tions other
than the
specified
positions.
“R”
3 - 8
“N”
1 - 2, 3 - 9
“D”
3 - 6
“2”
3 - 5
“1”
3 - 4
SCIA5588E
SCIA6370J
TM-48
< COMPONENT DIAGNOSIS >
[TYPE 1 (4AT: RE4F03B)]
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
Description
INFOID:0000000001694291
The A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT-III Reference Value in Data Monitor Mode
INFOID:0000000001694292
Remarks: Specification data are reference values.
On Board Diagnosis Logic
INFOID:0000000001694293
• This is an OBD self-diagnostic item.
• Diagnostic trouble code “P0710 ATF TEMP SEN/CIRC” with CONSULT-III is detected when TCM receives
an excessively low or high voltage from the sensor.
Possible Cause
INFOID:0000000001694294
• Harness or connector
(The sensor circuit is open or shorted.)
• A/T fluid temperature sensor
DTC Confirmation Procedure
INFOID:0000000001694295
CAUTION:
• Always drive vehicle at a safe speed.
• If performing this “DTC Confirmation Procedure” again, always turn ignition switch OFF and wait at
least 10 seconds before continuing.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-III
1.
Turn ignition switch ON and select “DATA MONITOR” mode for “A/T” with CONSULT-III.
2.
Touch “START”.
3.
Start engine and maintain the following conditions for at least 10 minutes (Total). (It is not necessary to
maintain continuously.)
ENGINE SPEED: 450 rpm or more
VEHICLE SPEED: 10 km/h (6 MPH) or more
THROTTLE POSI: More than 1.0/8
SLCT LVR POSI: “D” position
4.
If the check result is NG, go to
WITH GST
Follow the procedure “With CONSULT-III”.
Diagnosis Procedure
INFOID:0000000001694297
1.
CHECK INPUT SIGNAL
With CONSULT-III
1.
Start engine.
2.
Select “TCM INPUT SIGNALS” in “DATA MONITOR” mode for “A/T” with CONSULT-III.
3.
Read out the value of “FLUID TEMP SE”.
Item name
Condition
Display value (Approx.)
FLUID TEMP SE
When A/T fluid temperature is 20
°
C (68
°
F).
1.5V
When A/T fluid temperature is 80
°
C (176
°
F).
0.5V
Item name
Condition
Display value
(Approx.)
FLUID TEMP
SE
When A/T fluid temperature is 20
°
C (68
°
F).
1.5V
When A/T fluid temperature is 80
°
C (176
°
F).
0.5V
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
TM-49
< COMPONENT DIAGNOSIS >
[TYPE 1 (4AT: RE4F03B)]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
Without CONSULT-III
1.
Start engine.
2.
Check voltage TCM connector terminals while warming up A/T.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 2.
2.
DETECT MALFUNCTIONING ITEMS
Check the following.
• Harness for short or open between TCM, ECM and terminal cord assembly
• Ground circuit for ECM.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace damaged parts.
3.
CHECK FLUID TEMPERATURE SENSOR CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect the TCM connector.
3.
Check resistance between TCM connector terminals.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 4.
4.
CHECK HARNESS BETWEEN TCM AND TERMINAL CORD ASSEMBLY HARNESS CONNECTOR
1.
Turn ignition switch OFF.
2.
Disconnect terminal cord assembly harness connector and TCM connector.
3.
Check continuity between terminal cord assembly harness con-
nector terminal and TCM connector terminal.
4.
If OK, check harness for short to ground and short to power.
5.
If OK, check continuity between ground and transaxle assembly.
6.
Reinstall any part removed.
Item
Connec-
tor
Terminal
Condition
Judge-
ment stan-
dard
(Approx.)
A/T fluid
temperature
sensor
E32
47 - 42
When A/T fluid tempera-
ture is 20
°
C (68
°
F).
1.5V
When A/T fluid tempera-
ture is 80
°
C (176
°
F).
0.5V
SCIA2658E
Item
Connector
Terminal
Tempera-
ture [
°
C (
°
F)]
Resistance
(Approx.)
A/T fluid
temperature
sensor
E32
47 - 42
20 (68)
2.5 k
Ω
80 (176)
0.3 k
Ω
SCIA2338E
Item
Connector
Terminal Continuity
TCM
E32
42
Yes
Terminal cord assembly
harness connector
F30
7
TCM
E32
47
Yes
Terminal cord assembly
harness connector
F30
6
SCIA2660E
TM-50
< COMPONENT DIAGNOSIS >
[TYPE 1 (4AT: RE4F03B)]
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
OK or NG
OK
>> GO TO 5.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK A/T FLUID TEMPERATURE SENSOR WITH TERMINAL CORD ASSEMBLY
1.
Turn ignition switch OFF.
2.
Disconnect terminal cord assembly harness connector in engine room.
3.
Check resistance between terminal cord assembly harness con-
nector terminals.
4.
Reinstall any part removed.
OK or NG
OK
>> GO TO 6.
NG
>> Repair or replace damaged parts.
6.
DETECT MALFUNCTIONING ITEM
1.
Remove oil pan. Refer to
TM-191, "Control Valve Assembly and Accumulators"
.
2.
Check the following.
-
A/T fluid temperature sensor
•
Check resistance between terminal cord assembly harness con-
nector terminals while changing temperature as shown.
-
Harness of terminal cord assembly for short or open
OK or NG
OK
>> GO TO 7.
NG
>> Repair or replace damaged parts.
7.
CHECK DTC
Perform
TM-48, "DTC Confirmation Procedure"
.
OK or NG
OK
>> INSPECTION END
NG
>> GO TO 8.
8.
CHECK TCM
1.
Check TCM input/output signal. Refer to
.
2.
If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace damaged parts.
Component Inspection
INFOID:0000000001694298
A/T FLUID TEMPERATURE SENSOR
Temperature [
°
C (
°
F)]
Resistance (Approx.)
20 (68)
2.5 k
Ω
80 (176)
0.3 k
Ω
SCIA4948E
Temperature [
°
C (
°
F)]
Resistance (Approx.)
20 (68)
2.5 k
Ω
80 (176)
0.3 k
Ω
SAT298F