Nissan Tiida C11. Instruction — part 539
EC-806
< COMPONENT DIAGNOSIS >
[MR18DE]
P0112, P0113 IAT SENSOR
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace mass air flow sensor (with intake air temperature sensor).
Terminals
Condition
Resistance
5 and 6
Temperature
°
C (
°
F)
25 (77)
1.800 - 2.200 k
Ω
P0117, P0118 ECT SENSOR
EC-807
< COMPONENT DIAGNOSIS >
[MR18DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0117, P0118 ECT SENSOR
Description
INFOID:0000000001161776
The engine coolant temperature sensor is used to detect the engine
coolant temperature. The sensor modifies a voltage signal from the
ECM. The modified signal returns to the ECM as the engine coolant
temperature input. The sensor uses a thermistor which is sensitive to
the change in temperature. The electrical resistance of the ther-
mistor decreases as temperature increases.
<Reference data>
*: These data are reference values and are measured between ECM terminal 38
(Engine coolant temperature sensor) and 44.
DTC Logic
INFOID:0000000001161777
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON and wait at least 5 seconds.
2.
Check DTC.
Is DTC detected?
YES
>> Go to
NO
>> INSPECTION END
SEF594K
Engine coolant temperature
°
C (
°
F)
Voltage*
V
Resistance
k
Ω
–10 (14)
4.4
7.0 - 11.4
20 (68)
3.5
2.1 - 2.9
50 (122)
2.2
0.68 - 1.00
90 (194)
0.9
0.236 - 0.260
SEF012P
DTC No.
Trouble Diagnosis
Name
DTC Detecting Condition
Possible Cause
P0117
Engine coolant tem-
perature sensor cir-
cuit low input
An excessively low voltage from the sensor is
sent to ECM.
• Harness or connectors
(The sensor circuit is open or shorted.)
• Engine coolant temperature sensor
P0118
Engine coolant tem-
perature sensor cir-
cuit high input
An excessively high voltage from the sensor is
sent to ECM.
EC-808
< COMPONENT DIAGNOSIS >
[MR18DE]
P0117, P0118 ECT SENSOR
Diagnosis Procedure
INFOID:0000000001161778
1.
CHECK GROUND CONNECTION
1.
Turn ignition switch OFF.
2.
Check ground connection E15. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK ECT SENSOR POWER SUPPLY CIRCUIT
1.
Disconnect engine coolant temperature (ECT) sensor harness connector.
2.
Turn ignition switch ON.
3.
Check the voltage between ECT sensor harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK ECT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between ECT sensor harness connector and ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK ENGINE COOLANT TEMPERATURE SENSOR
EC-808, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace engine coolant temperature sensor.
5.
CHECK INTERMITTENT INCIDENT
GI-55, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000001161779
1.
CHECK ENGINE COOLANT TEMPERATURE SENSOR
1.
Turn ignition switch OFF.
2.
Disconnect engine coolant temperature sensor harness connector.
3.
Remove engine coolant temperature sensor.
ECT sensor
Ground
Voltage
Connector
Terminal
F6
1
Ground
Approx. 5V
ECT sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F6
2
F11
44
Existed
P0117, P0118 ECT SENSOR
EC-809
< COMPONENT DIAGNOSIS >
[MR18DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
4.
Check resistance between engine coolant temperature sensor
terminals by heating with hot water as shown in the figure.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace engine coolant temperature sensor.
Terminals
Condition
Resistance
1 and 2
Temperature
°
C (
°
F)
20 (68)
2.1 - 2.9 k
Ω
50 (122)
0.68 - 1.00 k
Ω
90 (194)
0.236 - 0.260 k
Ω
JMBIA0080ZZ