Nissan Sentra. Instruction — part 247
DLK-104
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR SWITCH
YES
>> Inspection End.
NO
>> Replace malfunction door switch.
HAZARD FUNCTION
DLK-105
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
HAZARD FUNCTION
Component Function Check
INFOID:0000000009756405
1.
CHECK FUNCTION
1. Select INTELLIGENT KEY of BCM using CONSULT.
2. Select FLASHER in ACTIVE TEST mode.
3. Touch LH or RH to check that it works normally.
Is the inspection result normal?
YES
>> Hazard warning lamp circuit is OK.
NO
>> Refer to
DLK-105, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000009756406
1.
CHECK HAZARD SWITCH CIRCUIT
EXL-105, "Component Function Check"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
.
>> Inspection End.
DLK-106
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
INTELLIGENT KEY
INTELLIGENT KEY
Component Function Check
INFOID:0000000009756407
NOTE:
The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II
User Guide for additional information.
• Check Intelligent Key relative signal strength.
• Confirm vehicle Intelligent Key antenna signal strength.
1.
CHECK FUNCTION
1. Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2. Select “RKE OPE COUN1” in “DATA MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Intelligent Key is OK.
NO
>> Refer to
DLK-106, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000009756408
NOTE:
The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II
User Guide for additional information.
• Check Intelligent Key relative signal strength.
• Confirm vehicle Intelligent Key antenna signal strength.
1.
CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300
Ω) so that the
current value becomes about 10 mA. Refer to
.
Is the measurement value within the specification?
YES
>> Replace Intelligent Key.
NO
>> Replace Intelligent Key battery.
Monitor item
Condition
RKE OPE COUN1
Check that the numerical value is changing while operating on the Intelligent Key.
Standard
: Approx. 2.5 - 3.0V
OCC0607D
KEY WARNING LAMP
DLK-107
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
KEY WARNING LAMP
Component Function Check
INFOID:0000000009756409
1.
CHECK FUNCTION
1. Select INTELLIGENT KEY of BCM using CONSULT.
2. Select INDICATOR in ACTIVE TEST mode.
3. Touch KEY IND or KEY ON to check that it works normally.
Is the inspection result normal?
YES
>> Key warning lamp is OK.
NO
>> Refer to
DLK-107, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000009756410
1.
CHECK KEY WARNING LAMP
DLK-31, "WARNING FUNCTION : System Description"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
.
>> Inspection End.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.