Nissan Quest E52. Instruction — part 725

HAC-30

< SYSTEM DESCRIPTION >

[AUTOMATIC AIR CONDITIONING]

SYSTEM

AIR DISTRIBUTION

Switch position

Door position

Rear mode door

Rear air mix door

AUTO switch

Front A/C control

AUTO

Rear A/C control

MODE switch

C

D

E

Temperature control switch (driver side) (front A/C control)

or temperature control switch (rear A/C control)

Full cold

18.0

°

C (60

°

F)

A

18.5

°

C

31.5

°

C

(61

°

F – 89

°

F)

AUTO

Full hot

32.0

°

C (90

°

F)

B

ON·OFF switch (front A/C control)

OFF

E

OFF switch (rear A/C control)

Discharge air flow

Mode position

Air outlet/distribution

Rear ventilator

Rear foot

100%

62%

38%

100%

SYSTEM

HAC-31

< SYSTEM DESCRIPTION >

[AUTOMATIC AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

REAR AUTOMATIC AIR CONDITIONING SYSTEM : Circuit Diagram

INFOID:0000000009652523

ACCS (ADVANCED CLIMATE CONTROL SYSTEM)

JMIIA1863GB

HAC-32

< SYSTEM DESCRIPTION >

[AUTOMATIC AIR CONDITIONING]

SYSTEM

ACCS (ADVANCED CLIMATE CONTROL SYSTEM) : System Description

INFOID:0000000009652524

SYSTEM DIAGRAM

DESCRIPTION

ACCS (advanced climate control system) controls passenger room air. It maintains the cleanliness of the pas-
senger room air using a high performance filter and a combination of each of the following functions.
• Automatic intake control (exhaust gas/outside odor detecting mechanism)
• Plasmacluster

ion

NOTE:
• Plasmacluster

ion technology developed by Sharp Corporation is installed in this item.

• Plasmacluster

is a trademark of Sharp Corporation.

AUTOMATIC INTAKE CONTROL (EXHAUST GAS/OUTSIDE ODOR DETECTING MECHANISM)

Description

In addition to air inlet automatic control of front automatic air conditioning system, A/C auto amp. controls
automatically air inlet according to signal from exhaust gas/outside odor detecting sensor, so that exhaust gas
and unpleasant outside odor does not enter in passenger room.

Operation Description

• When AUTO intake switch is pressed while front blower motor is activated, AUTO intake indicator and REC

indicator turn ON. Air inlet is fixed to recirculation for approximately 5 minutes, and then is switched to auto-
matic intake control (exhaust gas/outside odor detecting mechanism).

• Air inlet switches to recirculation when ambient atmospheric CO,

NO

2

and unpleasant odor is detected while automatic intake con-

trol (exhaust gas/outside odor detecting mechanism) is operated.
After that, air inlet switches to fresh air intake when exhaust gas
and unpleasant outside odor becomes not detectable.

• When the AUTO intake switch is turned ON, ambient atmosphere

status is indicated on the display in the front A/C control according
to the signal from the exhaust gas/outside odor detecting sensor.
Refer to

HAC-44, "ACCS (ADVANCED CLIMATE CONTROL SYS-

TEM) : Switch Name and Function"

.

NOTE:
• Sensitivity of exhaust gas/outside odor detecting sensor can be

changed. Refer to

HAC-85, "Exhaust Gas/Outside Odor Detecting Sensor Sensitivity Adjustment Function"

.

• Automatic intake control (exhaust gas/outside odor detecting mechanism) does not operate when air outlet

is D/F, DEF mode or ambient temperature is 0

°

C (32

°

F) or less. In this case, control is only for control of

automatic air inlet of automatic air conditioning system.

PLASMACLUSTER

ION

Description

JMIIA1773GB

JMIIA1779GB

SYSTEM

HAC-33

< SYSTEM DESCRIPTION >

[AUTOMATIC AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

Plasmacluster

ion restrains microbes, reduces odor on interior surface, and maintains passenger

s skin

moisture

*

by including high density Plasmacluster

ion in front air conditioning outlet air flow.

*: Effect depends on individual difference and operating conditions. Tasted by Soiken CO., Ltd. Ion density is
25,000 pcs/cm

3

. Skin moisture is measured at the temple of person being tested.

NOTE:
• Plasmacluster

ion technology developed by Sharp Corporation is installed in this item.

• Plasmacluster

is a trademark of Sharp Corporation.

Operation Description

• Plasmacluster

ion operates by interlocking to front blower motor. Plasmacluster

ion operates when front

blower motor operates.

• Control status is displayed on front A/C control display screen. Refer to

HAC-39, "REAR AUTOMATIC AIR

CONDITIONING SYSTEM : Switch Name and Function"

.

ACCS (ADVANCED CLIMATE CONTROL SYSTEM) : Circuit Diagram

INFOID:0000000009652525

JMIIA1864GB