Nissan Quest E52. Instruction — part 648

EXL-196

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN TYPE]

HAZARD SWITCH

HAZARD SWITCH

Component Function Check

INFOID:0000000009653172

1.

CHECK HAZARD SWITCH SIGNAL BY CONSULT

CONSULT DATA MONITOR

1.

Turn ignition switch ON.

2.

Select “HAZARD SW” of BCM (FLASHER) data monitor item.

3.

With operating the hazard switch, check the monitor status.

Is the inspection result normal?

YES

>> Hazard switch circuit is normal.

NO

>> Refer to

EXL-196, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009653173

1.

CHECK HAZARD SWITCH SIGNAL INPUT

1.

Turn ignition switch OFF.

2.

Disconnect hazard switch connector.

3.

Check voltage between hazard switch connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> GO TO 2.

2.

CHECK HAZARD SWITCH SIGNAL OPEN CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between hazard switch harness connector and BCM harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT

Check continuity between hazard switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-98, "Removal and Installation"

.

NO

>> Repair or replace harness.

Monitor item

Condition

Monitor status

HAZARD SW

Hazard switch

ON

On

OFF

Off

(+)

(

)

Voltage (Approx.)

Hazard switch

Connector

Terminal

M45

2

Ground

12 V

Hazard switch

BCM

Continuity

Connector

Terminal

Connector

Terminal

M45

2

M121

29

Existed

Hazard switch

Ground

Continuity

Connector

Terminal

M45

2

Not existed

HAZARD SWITCH

EXL-197

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

4.

CHECK HAZARD SWITCH GROUND OPEN CIRCUIT

Check continuity between hazard switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace hazard switch.

NO

>> Repair or replace harness.

Hazard switch

Ground

Continuity

Connector

Terminal

M45

1

Existed

EXL-198

< SYMPTOM DIAGNOSIS >

[HALOGEN TYPE]

EXTERIOR LIGHTING SYSTEM SYMPTOMS

SYMPTOM DIAGNOSIS

EXTERIOR LIGHTING SYSTEM SYMPTOMS

WITHOUT DAYTIME RUNNING LIGHT SYSTEM

WITHOUT DAYTIME RUNNING LIGHT SYSTEM : Symptom Table

INFOID:0000000009653174

CAUTION:

Perform the self-diagnosis with CONSULT before the symptom diagnosis. Perform the trouble diagno-
sis if any DTC is detected.

Symptom

Possible cause

Inspection item

Headlamp (HI) is not
turned ON.

One side

• Fuse
• Halogen bulb (HI)
• Harness between IPDM E/R

and headlamp (HI)

• Harness between headlamp

(HI) and ground

• IPDM E/R

Headlamp (HI) circuit
Refer to

EXL-174, "WITHOUT DAY-

TIME RUNNING LIGHT SYSTEM :
Component Function Check"

.

Both sides

Symptom diagnosis
“BOTH SIDE HEADLAMPS (HI) ARE NOT TURNED ON”
Refer to

EXL-204, "WITHOUT DAYTIME RUNNING LIGHT SYSTEM :

Diagnosis Procedure"

.

High beam indicator lamp is not turned ON.
[Headlamp (HI) is turned ON.]

Combination meter

• Combination meter

Data monitor “HI-BEAM IND”

• BCM (HEAD LAMP)

Active test “HEADLAMP”

Headlamp (LO) is not
turned ON.

One side

• Fuse
• Halogen bulb (LO)
• Harness between IPDM E/R

and headlamp lamp (LO)

• Harness between headlamp

(LO) and ground

• IPDM E/R

Headlamp (LO) circuit
Refer to

EXL-178, "Component

Function Check"

.

Both sides

Symptom diagnosis
“BOTH SIDE HEADLAMPS (LO) ARE NOT TURNED ON”
Refer to

EXL-206, "Diagnosis Procedure"

.

Each lamp is not turned ON/OFF with lighting switch
AUTO.

• Combination switch
• Harness between combination

switch and BCM

• BCM

Combination switch
Refer to

BCS-96, "Symptom Table"

.

• Optical sensor
• Harness between optical sen-

sor and BCM

• BCM

Optical sensor
Refer to

EXL-193, "Component

Function Check"

.

Parking lamp is not turned ON.

• Fuse
• Parking lamp bulb
• Harness between IPDM E/R

and front combination lamp

• Harness between front combi-

nation lamp and ground

• IPDM E/R

Parking lamp circuit
Refer to

EXL-182, "Component

Function Check"

.

Front side marker lamp is not turned ON.

• Front side marker lamp bulb
• Harness between IPDM E/R

and front side marker lamp

• Harness between front side

marker lamp and ground

Front side marker lamp circuit
Refer to

EXL-184, "Component

Function Check"

.

EXTERIOR LIGHTING SYSTEM SYMPTOMS

EXL-199

< SYMPTOM DIAGNOSIS >

[HALOGEN TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

WITH DAYTIME RUNNING LIGHT SYSTEM

Tail lamp (Rear side marker lamp) is not turned ON.

• Fuse
• Tail lamp bulb
• Harness between IPDM E/R

and rear combination lamp

• Harness between rear combi-

nation lamp and ground

• IPDM E/R

Tail lamp circuit
Refer to

EXL-185, "Component

Function Check"

.

License plate lamp is not turned ON.

• License plate lamp bulb
• Harness between IPDM E/R

and license plate lamp

• Harness between license plate

lamp and ground

License plate lamp circuit
Refer to

EXL-187, "Component

Function Check"

.

Parking lamp, side marker lamp, tail lamp and li-
cense plate lamp are not turned ON.

Symptom diagnosis
“PARKING, SIDE MARKER, LICENSE PLATE AND TAIL LAMPS ARE
NOT TURNED ON”
Refer to

EXL-207, "Diagnosis Procedure"

.

Tail lamp indicator is not turned ON.
(Exterior lamps are turned ON.)

Combination meter

• Combination meter

Data monitor “LIGHT IND”

• BCM (HEADLAMP)

Active test “TAIL LAMP”

Turn signal lamp does not
blink.

Indicator lamp is nor-
mal.
(Applicable side per-
forms high flasher acti-
vation.)

• Turn signal lamp bulb
• Door mirror
• Harness between BCM and

each turn signal lamp

• Harness between each turn sig-

nal lamp and ground

Turn signal lamp circuit
Refer to

EXL-188, "Component

Function Check"

.

Indicator lamp is includ-
ed.

• Combination switch
• Harness between combination

switch and BCM

• BCM

Combination switch
Refer to

BCS-96, "Symptom Table"

.

Turn signal indicator lamp
does not blink.
(Turn signal lamp is nor-
mal.)

One side

Combination meter

Both sides
(Always)

• Turn signal indicator lamp sig-

nal

• BCM
• Combination meter

• Combination meter

Data monitor “TURN IND”

• BCM (FLASHER)

Active test “FLASHER”

Both sides
(Only when activating
hazard warning lamp
with ignition switch
OFF)

• Combination meter power sup-

ply and ground circuit

• Combination meter

Combination meter
Power supply and ground circuit
Refer to

MWI-72, "COMBINATION

METER : Diagnosis Procedure"

.

• Hazard warning lamp does not activate.
• Hazard warning lamp continues activating.
(Turn signal is normal.)

• Hazard switch
• Harness between hazard

switch and BCM

• Harness between hazard

switch and ground

• BCM

Hazard switch circuit
Refer to

EXL-196, "Component

Function Check"

.

Front fog lamp is not
turned ON.

One side

• Front fog lamp bulb
• Harness between IPDM E/R

and front fog lamp

• Harness between front fog lamp

and ground

• IPDM E/R

Front fog lamp circuit
Refer to

EXL-191, "Component

Function Check"

.

Both sides

Symptom diagnosis
“BOTH SIDE FRONT FOG LAMPS ARE NOT TURNED ON”
Refer to

EXL-208, "Description"

.

Symptom

Possible cause

Inspection item

Была ли эта страница вам полезна?
Да!Нет
4 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности