Nissan Quest E52. Instruction — part 1213
TM-82
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F09B]
P0705 TRANSMISSION RANGE SWITCH A
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace the transaxle assembly due to malfunction in the transmission range switch. Refer to
174, "Removal and Installation"
.
CVT unit
—
Condition
Continuity
Terminal
4
Ground
Selector lever in “N”, “D”, and “L” positions
Existed
Selector lever in other positions
Not existed
5
Selector lever in “D” and “L” positions
Existed
Selector lever in other positions
Not existed
14
Selector lever in “R” and “D” positions
Existed
Selector lever in other positions
Not existed
15
Selector lever in “D” and “L” positions
Existed
Selector lever in other positions
Not existed
18
Selector lever in “R”, “N”, and “D” positions
Existed
Selector lever in other positions
Not existed
P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A
TM-83
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F09B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A
DTC Logic
INFOID:0000000009650137
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
CAUTION:
Always drive vehicle at a safe speed.
1.
PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and
wait at least 10 seconds before conducting the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION (PART 1)
1.
Start the engine.
2.
Maintain the following condition for 5 seconds or more.
3.
Stop the vehicle.
4.
Check the first trip DTC.
Is “P0710” detected?
YES
>> Go to
NO
>> GO TO 3.
3.
CHECK DTC DETECTION (PART 2)
With CONSULT
1.
Turn ignition switch OFF and cool the engine.
2.
Turn ignition switch ON.
CAUTION:
Never start the engine.
3.
Select “Data Monitor” in “TRANSMISSION”.
4.
Select “FLUID TEMP”.
5.
Record CVT fluid temperature.
6.
Start the engine and wait for at least 2 minutes.
7.
Drive the vehicle for the total minutes specified in the Driving time column below with the following condi-
tions satisfied.
DTC
Trouble diagnosis name
DTC detected condition
Possible cause
P0710
Transmission Fluid Tempera-
ture Sensor “A” Circuit
CVT fluid temperature recognized by TCM keeps
above 180
°
C (356
°
F) for 5 seconds or more
• Harness or connectors
(Sensor circuit is open or shorted.)
• CVT fluid temperature sensor
When below diagnosis conditions are met, CVT
fluid temperature recognized by TCM keeps be-
low
−
40
°
C (
−
40
°
F) for 5 seconds or more
• Diagnosis Condition
- Vehicle speed: 11 km/h (7 MPH) or more
CVT fluid temperature does not rise to 10
°
C
(50
°
F) after driving for a certain period of time with
the TCM-received fluid temperature sensor value
between
−
40
°
C (
−
40
°
F) and 9
°
C (48.2
°
F).
The following conditions are maintained for 5 min-
utes after the completion of engine diagnosis
P0111, P0116, and P0196:
• CVT fluid temperature
−
Engine coolant tem-
perature > 55
°
C (131
°
F)
• CVT fluid temperature
−
Engine coolant tem-
perature <
−
27
°
C (
−
16.6
°
F)
CVT fluid temperature sensor
Vehicle speed
: 20 km/h (12 MPH) or more
TM-84
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F09B]
P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A
8.
Stop the vehicle.
9.
Check the first trip DTC.
With GST
1.
Turn ignition switch OFF and cool the engine.
2.
Start the engine and wait for at least 2 minutes.
3.
Drive the vehicle and maintain the following conditions for 17 minutes or more.
4.
Stop the vehicle.
5.
Check the first trip DTC.
Is “P0710” detected?
YES
>> Go to
NO
>> GO TO 4.
4.
CHECK CVT FLUID TEMPERATURE SENSOR
1.
Turn ignition switch OFF.
2.
Disconnect CVT unit connector.
3.
Check resistance between CVT unit connector terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace the transaxle assembly due to malfunction in the CVT fluid temperature sensor. Refer to
TM-174, "Removal and Installation"
Diagnosis Procedure
INFOID:0000000009650138
1.
CHECK CVT FLUID TEMPERATURE SENSOR
1.
Turn ignition switch OFF.
2.
Disconnect the CVT unit connector.
3.
Check the CVT fluid temperature sensor. Refer to
TM-85, "Component Inspection (CVT Fluid Tempera-
Is the inspection result normal?
YES
>> GO TO 2.
Selector lever
: “D” position
Accelerator pedal position
: 1.0/8 or more
Vehicle speed
: 10 km/h (7 MPH) or more
CVT fluid temperature before engine start
Driving time
−
40
°
C (
−
40
°
F) –
−
31
°
C (
−
23.8
°
F)
17 minutes or more
−
30
°
C (
−
22
°
F) –
−
21
°
C (
−
5.8
°
F)
15 minutes or more
−
20
°
C (
−
4
°
F) –
−
11
°
C (
−
12.2
°
F)
12 minutes or more
−
10
°
C (14
°
F) –
−
1
°
C (30.2
°
F)
9 minutes or more
0
°
C (32
°
F) – 9
°
C (48.2
°
F)
6 minutes or more
Other than the above
—
(Go to 4.)
Selector lever
: “D” position
Accelerator pedal position
: 1.0/8 or more
Vehicle speed
: 10 km/h (7 MPH) or more
CVT unit
Condition
Resistance
(Approx.)
Terminal
17 – 19
CVT fluid temperature: 20
°
C (68
°
F)
6.29 – 6.83 k
Ω
CVT fluid temperature: 50
°
C (122
°
F)
2.10 – 2.15 k
Ω
CVT fluid temperature: 80
°
C (176
°
F)
0.85 – 0.90 k
Ω
P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A
TM-85
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F09B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
NO
>> Replace the transaxle assembly due to malfunction in the CVT fluid temperature sensor. Refer to
TM-174, "Removal and Installation"
2.
CHECK HARNESS BETWEEN TCM AND CVT UNIT
1.
Disconnect the TCM connector.
2.
Check continuity between TCM harness connector terminals and CVT unit harness connector terminals.
3.
Check continuity between TCM harness connector terminals and ground.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-42, "Intermittent Incident"
.
NO
>> Repair or replace damaged parts.
Component Inspection (CVT Fluid Temperature Sensor)
INFOID:0000000009650139
1.
CHECK CVT FLUID TEMPERATURE SENSOR
1.
Check the resistance between CVT unit connector terminals.
2.
Check the continuity between CVT unit connector terminal and ground.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace the transaxle assembly due to malfunction in the CVT fluid temperature sensor. Refer to
TM-174, "Removal and Installation"
TCM
CVT unit
Continuity
Connector
Terminal
Connector
Terminal
F23
13
F24
17
Existed
25
19
TCM
—
Continuity
Connector
Terminal
F23
13
Ground
Not existed
25
CVT unit
Condition
Resistance (Approx.)
Terminal
17
19
When CVT fluid temperature is 20
°
C (68
°
F)
6.29 – 6.83 k
Ω
When CVT fluid temperature is 50
°
C (122
°
F)
2.10 – 2.25 k
Ω
When CVT fluid temperature is 80
°
C (176
°
F)
0.85 – 0.90 k
Ω
CVT unit
—
Continuity
Terminal
17
Ground
Not existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст