< DTC/CIRCUIT DIAGNOSIS >
B2412 AUTOMATIC SLIDING DOOR MOTOR/ENCODER
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
NO
>> Repair or replace harness.
4.
CHECK ENCODER CIRCUIT 2
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace harness.
5.
CHECK ENCODER GROUND CIRCUIT
1.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
2.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace harness.
6.
CHECK ENCODER CIRCUIT 3
1.
Connect sliding door control unit LH connector and automatic sliding door unit LH connector.
2.
Check voltage between sliding door control unit LH harness connector and ground.
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B45
11
B65
5
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
11
Not existed
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B45
4
B65
6
Existed
21
7
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
4
Not existed
21
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B45
26
B65
8
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
26
Not existed
B2412 AUTOMATIC SLIDING DOOR MOTOR/ENCODER
DLK-199
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace automatic sliding door unit LH.
NO
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
7.
CHECK AUTOMATIC SLIDING DOOR MOTOR CIRCUIT
1.
Disconnect sliding door control unit LH connector and automatic sliding door unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit LH.
NO
>> Repair or replace harness.
SLIDING DOOR RH
SLIDING DOOR RH : DTC Logic
INFOID:0000000009649097
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON.
2.
Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR RIGHT” using CONSULT.
Is DTC detected?
YES
>> Refer to
DLK-199, "SLIDING DOOR RH : Diagnosis Procedure"
.
NO
>> INSPECTION END
SLIDING DOOR RH : Diagnosis Procedure
INFOID:0000000009649098
1.
CHECK ENCODER MONITOR ITEM
1.
Select “AUTO SLDE DOOR RIGHT” using CONSULT.
2.
Select “ENCODER A RH ” and “ENCODER B RH” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
(+)
(–)
Voltage
Sliding door control unit LH
Connector
Terminal
B45
26
Ground
0 V
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B47
43
B33
3
Existed
46
4
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B47
43
Not existed
46
DTC
CONSULT display
description
DTC detecting condition
Possible cause
B2412
ASD MTR/ENCDR
When sliding door control unit transmits signal to
automatic sliding door motor but pulse signal from
encoder is not detected for 1 second or more
• Sliding door motor
• Encoder
• Harness or connectors
DLK-200
< DTC/CIRCUIT DIAGNOSIS >
B2412 AUTOMATIC SLIDING DOOR MOTOR/ENCODER
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 2.
2.
CHECK ENCODER POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect automatic sliding door unit RH connector.
3.
Check voltage between automatic sliding door unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
CHECK ENCODER CIRCUIT 1
1.
Disconnect sliding door control unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit RH. Refer to
DLK-500, "RH : Removal and Installation"
NO
>> Repair or replace harness.
4.
CHECK ENCODER CIRCUIT 2
1.
Disconnect sliding door control unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Monitor item
Condition
Status
ENCODER A RH
Sliding door RH
Moving (auto or instruction)
HI
⇔
LO
When stopped
HI or LO
ENCODER B RH
Sliding door RH
Moving (auto or instruction)
HI
⇔
LO
When stopped
HI or LO
(+)
(–)
Voltage
Automatic sliding door unit RH
Connector
Terminal
B244
5
Ground
8 – 16 V
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B247
11
B244
5
Existed
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B247
11
Not existed
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B247
4
B244
7
Existed
21
6
B2412 AUTOMATIC SLIDING DOOR MOTOR/ENCODER
DLK-201
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace harness.
5.
CHECK ENCODER GROUND CIRCUIT
1.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
2.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace harness.
6.
CHECK ENCODER CIRCUIT 3
1.
Connect sliding door control unit RH connector and automatic sliding door unit RH connector.
2.
Check voltage between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit RH.
NO
>> Replace sliding door control unit RH. Refer to
DLK-500, "RH : Removal and Installation"
7.
CHECK AUTOMATIC SLIDING DOOR MOTOR CIRCUIT
1.
Disconnect sliding door control unit RH connector and automatic sliding door unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B247
4
Not existed
21
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B247
26
B244
8
Existed
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B247
26
Not existed
(+)
(–)
Voltage
Sliding door control unit RH
Connector
Terminal
B247
26
Ground
0 V
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B249
43
B245
4
Existed
46
3
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B249
43
Not existed
46