Nissan Cube. Instruction — part 534
REFRIGERANT
HA-25
< PERIODIC MAINTENANCE >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
2.
Operate recovery/recycling/recharging equipment, and evacuate air from A/C system for 25 minutes or
more.
CAUTION:
Evacuate air for 15 minutes or more if the parts are replaced.
3.
Check the airtightness of A/C system for 25 minutes or more. If pressure rises more than the specified
level, charge A/C system with approximately 200 g (0.4 lb) refrigerant and check that there is no refriger-
ant leakage. Refer to
CAUTION:
Check the airtightness for 15 minutes or more if the parts are replaced.
4.
If parts other than compressor are replaced, fill compressor lubricant according to parts that are replaced.
5.
Charge the specified amount of refrigerant to A/C system.
6.
Check that A/C system operates normally.
7.
Disconnect recovery/recycling/recharging equipment. (Collect the refrigerant from the high-pressure hose
and low-pressure hose of recovery/recycling/recharging equipment.)
8.
Install A/C service valve cap.
9.
Refrigerant charge is complete.
HA-26
< PERIODIC MAINTENANCE >
LUBRICANT
LUBRICANT
Description
INFOID:0000000009950342
MAINTENANCE OF LUBRICANT LEVEL
The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill com-
pressor with lubricant when replacing A/C system parts or when a large amount of refrigerant leakage is
detected. It is important to always maintain lubricant level within the specified level. Otherwise, the following
conditions may occur.
• Insufficient lubricant amount: Stuck compressor
• Excessive lubricant amount: Insufficient cooling (caused by insufficient heat exchange)
Inspection
INFOID:0000000009950343
If a compressor is malfunctioning (internal noise, insufficient cooling), check the compressor oil.
1.
COMPRESSOR OIL JUDGMENT
1.
Remove the compressor. Refer to
.
2.
Sample a compressor oil and judge on the figure.
Judgement result 1>>Replace compressor only.
Judgement result 2>>Replace compressor and liquid tank.
Perform Lubricant Return Operation
INFOID:0000000009950344
CAUTION:
If a large amount of refrigerant or lubricant leakage is detected, never perform lubricant return opera-
tion.
1.
Start the engine and set to the following conditions.
• Engine speed: Idling to 1,200 rpm
• A/C switch: ON
• Fan speed: Maximum speed set
• Intake door position: Recirculation
• Temperature setting: Full cold
2.
Perform lubricant return operation for approximately 10 minutes.
3.
Stop the engine.
4.
Lubricant return operation is complete.
Lubricant Adjusting Procedure for Components Replacement Except Compressor
INFOID:0000000009950345
Fill with lubricant for the amount that is calculated according to the following conditions.
Example: Lubricant amount to be added when replacing evaporator and liquid tank [m (US fl oz., Imp fl oz.)]
= 35 (1.2, 1.2) + 5 (0.2, 0.2) +
α
Name
: A/C System Oil Type R
JSIIA0927GB
LUBRICANT
HA-27
< PERIODIC MAINTENANCE >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Lubricant Adjusting Procedure for Compressor Replacement
INFOID:0000000009950346
1.
Drain lubricant from removed compressor and measure lubricant amount.
1.
Drain lubricant from high-pressure port (A) and low-pres-
sure port (B) while rotating magnet clutch.
2.
Measure total amount of lubricant that is drained from
removed compressor.
2.
Drain lubricant from a new compressor that is calculated accord-
ing to the following conditions.
CAUTION:
If lubricant amount that is drained from removed compressor is less than 60 m (2.0 US fl oz., 2.1
Imp fl oz.), perform calculation by setting “D” as 40 m (1.4 US fl oz., 1.4 Imp fl oz.).
Example: Lubricant amount to be drained from a new compressor when replacing compressor and liquid
tank [m (US fl oz., Imp fl oz.)] [D = 60 (2.0, 2.1),
α
= 5 (0.2, 0.2)]
120 (4.1, 4.2)
−
[60 (1.5, 1.6) + 20 (0.7, 0.7) + 5 (0.2, 0.2) + 5 (0.2, 0.2)] = 30 (1.0, 1.0)
Conditions
Lubricant amount to be added to A/C system
m
(US fl oz., Imp fl oz.)
Replace evaporator
35 (1.2, 1.2)
Replace condenser
15 (0.5, 0.5)
Replace liquid tank
5 (0.2, 0.2)
Refrigerant leakage is detected
Large amount leakage
30 (1.0, 1.1)
Small amount leakage
—
Lubricant amount that is recycled together with refrigerant during recycle operation
α
JMIIA0940ZZ
Amount to be drained (A) [m (US fl oz., Imp fl oz.)]
= F
−
(D + S + R +
α
)
F
: Lubricant amount that a new compressor
contains [120 (4.1, 4.2)]
D
: Lubricant amount that is drained from re-
moved compressor
S
: Lubricant amount that remains inside of re-
moved compressor [20 (0.7, 0.7)]
R
: Lubricant amount to be added according to
components that are removed except com-
pressor
α
: Lubricant amount that is recycled together
with refrigerant during recycle operation
Conditions
Lubricant amount to be added to A/C system
m
(US fl oz., Imp fl oz.)
Replace evaporator
35 (1.2, 1.2)
Replace condenser
15 (0.5, 0.5)
Replace liquid tank
5 (0.2, 0.2)
JPIIA1455GB
HA-28
< PERIODIC MAINTENANCE >
LUBRICANT
3.
Install compressor and check the operation.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст