Nissan March K13. Instruction — part 498
PCS-74
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2614 ACC RELAY CIRCUIT
YES
>> Replace BCM. Refer to
BCS-58, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK ACCESSORY RELAY GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Check continuity between accessory relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair accessory relay ground circuit.
4.
CHECK ACCESSORY RELAY POWER SUPPLY CIRCUIT-2
1.
Turn ignition switch ACC.
2.
Check voltage between accessory relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Check continuity open or short between accessory relay and battery.
5.
CHECK ACCESSORY RELAY
PCS-74, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace accessory relay.
6.
CHECK INTERMITTENT INCIDENT
GI-33, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000005998919
1.
CHECK ACCESSORY RELAY
1.
Turn ignition switch OFF.
2.
Remove accessory relay.
3.
Check the continuity between accessory relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace accessory relay
Accessory relay
Ground
Continuity
Terminal
2
Existed
(+)
(–)
Voltage (V)
(Approx.)
Accessory relay
Terminal
5
Ground
Battery voltage
Terminals
Condition
Continuity
3 and 5
12 V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
PBIB0098E
PCS
B2615 BLOWER RELAY CIRCUIT
PCS-75
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B2615 BLOWER RELAY CIRCUIT
DTC Logic
INFOID:0000000005998920
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON under the following conditions, and wait for 1 second or more.
-
Selector lever is in the P position
-
Do not depress brake pedal
2.
Check “Self-diagnosis result” with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000005998921
1.
CHECK BLOWER RELAY POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect blower relay.
3.
Check voltage between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK BLOWER RELAY POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect BCM connector.
3.
Check continuity between blower relay harness connector and BCM harness connector.
4.
Check continuity between blower relay harness connector and ground.
Is the inspection result normal?
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2615
BCM
BCM detects a difference of signal for 1 second or
more between the following items.
• Blower relay ON/OFF request
• Blower relay feedback
• Harness or connectors
(Blower relay circuit is open or
shorted)
• BCM
• Blower relay
(+)
(–)
Condition
Voltage (V)
(Approx.)
Blower relay
Terminal
1
Ground
Ignition switch
OFF or ACC
0
ON
Battery voltage
Blower relay
BCM
Continuity
Terminal
Connector
Terminal
1
M71
106
Existed
Blower relay
Ground
Continuity
Terminal
1
Not existed
PCS-76
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2615 BLOWER RELAY CIRCUIT
YES
>> GO TO 6.
NO
>> Repair or replace harness.
3.
CHECK BLOWER RELAY GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Check continuity between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair blower relay ground circuit.
4.
CHECK BLOWER RELAY POWER SUPPLY CIRCUIT-2
1.
Turn ignition switch ON or ACC.
2.
Check voltage between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Check continuity open or short between blower relay and battery.
5.
CHECK BLOWER RELAY
PCS-76, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace blower relay.
6.
CHECK INTERMITTENT INCIDENT
GI-33, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000005998922
1.
CHECK BLOWER RELAY
1.
Turn ignition switch OFF.
2.
Remove blower relay.
3.
Check the continuity between blower relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace blower relay
Blower relay
Ground
Continuity
Terminal
2
Existed
(+)
(–)
Voltage (V)
(Approx.)
Blower relay
Terminal
5
Ground
Battery voltage
Terminals
Condition
Continuity
3 and 5
12 V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
PBIB0098E
PCS
B2616 IGNITION RELAY CIRCUIT
PCS-77
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B2616 IGNITION RELAY CIRCUIT
DTC Logic
INFOID:0000000005998923
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON under the following conditions, and wait for 1 second or more.
-
Selector lever is in the P position
-
Do not depress brake pedal
2.
Check “Self-diagnosis result” with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000005998924
1.
CHECK IGNITION RELAY POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect ignition relay.
3.
Check voltage between ignition relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK IGNITION RELAY POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect BCM connector.
3.
Check continuity between ignition relay harness connector and BCM harness connector.
4.
Check continuity between ignition relay harness connector and ground.
Is the inspection result normal?
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2616
BCM
An immediate operation of ignition relay is request-
ed by BCM, but there is no response for more than
1 second
• Harness or connectors
(Ignition relay circuit is open or
shorted)
• BCM
• Ignition relay
(+)
(–)
Condition
Voltage (V)
(Approx.)
Ignition relay
Terminal
2
Ground
Ignition switch
OFF or ACC
0
ON
Battery voltage
Ignition relay
BCM
Continuity
Terminal
Connector
Terminal
2
M71
99
Existed
Ignition relay
Ground
Continuity
Terminal
2
Not existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.