Nissan March K13. Instruction — part 504
PG-4
< SYSTEM DESCRIPTION >
COMPONENT PARTS
SYSTEM DESCRIPTION
COMPONENT PARTS
Circuit Breaker
INFOID:0000000005911811
The PTC thermistor generates heat in response to current flow. The
temperature (and resistance) of the thermistor element varies with
current flow. Excessive current flow will cause the element's temper-
ature to rise. When the temperature reaches a specified level, the
electrical resistance will rise sharply to control the circuit current.
Reduced current flow will cause the element to cool. Resistance falls
accordingly and normal circuit current flow is allowed to resume.
Battery
INFOID:0000000005911812
NOTE:
For the battery type application, refer to the following list.
• Type 1
- For Pakistan without rear wiper
- For Thailand (M/T models)
• Type 2
- Except for Pakistan without rear wiper
- Except for Thailand (M/T models)
Harness Connector
INFOID:0000000005911813
HARNESS CONNECTOR (TAB-LOCKING TYPE)
• The tab-locking type connectors help prevent accidental looseness or disconnection.
• The tab-locking type connectors are disconnected by pushing or lifting the locking tab(s). Refer to the figure
below.
CAUTION:
Never pull the harness or wires when disconnecting the connector.
SEL109W
Application
Type 1
Type 2
Type
34B19L
46B19L
20 hour rate capacity
[V – Ah]
12 – 30
12 – 45
Cold cranking current (For reference value)
[A]
272
325
PG
COMPONENT PARTS
PG-5
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
[Example]
HARNESS CONNECTOR (SLIDE-LOCKING TYPE)
• A new style slide-locking type connector is used on certain systems and components, especially those
related to OBD.
• The slide-locking type connectors help prevent incomplete locking and accidental looseness or disconnec-
tion.
• The slide-locking type connectors are disconnected by pushing or pulling the slider. Refer to the figure
below.
CAUTION:
• Never pull the harness or wires when disconnecting the connector.
• Be careful not to damage the connector support bracket when disconnecting the connector.
SEL769DA
PG-6
< SYSTEM DESCRIPTION >
COMPONENT PARTS
[Example]
HARNESS CONNECTOR (LEVER LOCKING TYPE)
• Lever locking type harness connectors are used on certain control units and control modules such as ECM,
ABS actuator and electric unit (control unit), etc.
• Lever locking type harness connectors are also used on super multiple junction (SMJ) connectors.
• Always confirm the lever is fully locked in place by moving the lever as far as it will go to ensure full connec-
tion.
CAUTION:
SEL769V
PG
COMPONENT PARTS
PG-7
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
Always confirm the lever is fully released (loosened) before attempting to disconnect or connect these
connectors to avoid damage to the connector housing or terminals.
Standardized Relay
INFOID:0000000005911814
NORMAL OPEN, NORMAL CLOSED AND MIXED TYPE RELAYS
Relays can mainly be divided into three types: normal open, normal closed and mixed type relays.
TYPE OF STANDARDIZED RELAYS
LKIA0670E
1.
Control unit with single lever
A. Fasten
B. Loosen
C. Lever
2.
Control unit with dual levers
A. Levers
B. Fasten
C. Loosen
3.
SMJ connector
A. Lever
B. Fasten
C. Loosen
SEL881H