Nissan Primera P12. Instruction — part 257
DTC P0404 EGR VOLUME CONTROL VALVE
EC-213
[YD (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
Diagnostic Procedure
EBS016KZ
1.
CHECK EGR VOLUME CONTROL VALVE POWER SUPPLY CIRCUIT-I
1.
Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
2.
Check voltage between ECM terminals 119, 120 and ground
with CONSULT-II or tester.
OK or NG
OK
>> GO TO 2.
NG
>> Go to
EC-76, "MAIN POWER SUPPLY AND GROUND
.
2.
CHECK EGR VOLUME CONTROL VALVE POWER SUPPLY CIRCUIT-II
1.
Turn ignition switch OFF.
2.
Disconnect EGR volume control valve harness connector.
3.
Turn ignition switch ON.
4.
Check voltage between EGR volume control valve terminals 2, 5
and ground with CONSULT-II or tester.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 3.
Voltage: Battery voltage
MBIB1096E
MBIB0088E
Voltage: Battery voltage
PBIB0431E
EC-214
[YD (WITH EURO-OBD)]
DTC P0404 EGR VOLUME CONTROL VALVE
3.
CHECK EGR VOLUME CONTROL VALVE POWER SUPPLY CIRCUIT-III
1.
Turn ignition switch OFF.
2.
Disconnect ECM relay.
3.
Check voltage between ECM relay terminal 3 and ground with
CONSULT-II or tester.
OK or NG
OK
>> GO TO 5.
NG
>> GO TO 4.
4.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors E62, F12
●
10A fuse
●
Harness for open or short between ECM relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK EGR VOLUME CONTROL VALVE POWER SUPPLY CIRCUIT-IV
1.
Check harness continuity between ECM relay terminal 5 and EGR volume control valve terminals 2, 5.
Refer to Wiring Diagram.
2.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 6.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
6.
CHECK ECM RELAY
Refer to
EC-263, "Component Inspection"
.
OK or NG
OK
>> GO TO 7.
NG
>> Replace ECM relay.
MBIB1086E
Voltage: Battery voltage
PBIB0432E
Continuity should exist.
DTC P0404 EGR VOLUME CONTROL VALVE
EC-215
[YD (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
7.
CHECK EGR VOLUME CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between ECM terminals and EGR volume control valve terminals as follows.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 8.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
8.
CHECK EGR VOLUME CONTROL VALVE
Refer to
EC-215, "Component Inspection"
.
OK or NG
OK
>> GO TO 9.
NG
>> Replace EGR volume control valve.
9.
CHECK INTERMITTENT INCIDENT
Refer to
EC-75, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
>> INSPECTION END
Component Inspection
EBS016L0
EGR VOLUME CONTROL VALVE
With CONSULT-II
1.
Disconnect EGR volume control valve harness connector.
ECM terminal
EGR volume control valve terminal
25
1
26
6
27
3
28
4
Continuity should exist.
EC-216
[YD (WITH EURO-OBD)]
DTC P0404 EGR VOLUME CONTROL VALVE
2.
Check resistance between the following terminals.
●
terminal 2 and terminals 1, 3
●
terminal 5 and terminals 4, 6
If NG, replace EGR volume control valve.
If OK, go to next step.
3.
Remove EGR volume control valve from cylinder head.
4.
Reconnect EGR volume control valve harness connector.
5.
Turn ignition switch ON.
6.
Perform “EGR VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that EGR volume control
valve shaft moves smoothly forward and backward according to the valve opening.
If NG, replace the EGR volume control valve.
NOTE:
When installing the EGR volume control valve, make sure that the shaft is in the same position before
checking.
Without CONSULT-II
1.
Disconnect EGR volume control valve harness connector.
Temperature
°
C (
°
F)
Resistance
Ω
20 (68)
13 - 17
MBIB0007E
SEF819Y