Terminal and Reference Value for Power Window Main Switch

EIS005KC

Terminal and Reference Value for Each Door's Power Window Switch

EIS005KD

Terminal

Wire color

Item

Condition

Voltage (V)

(Approx.)

2

L/W

IGN power supply

Ignition switch (ON or START position)

Battery voltage

4

G

Driver power window motor
UP signal

When UP operation

Battery voltage

Other than above

0

5

P

Driver power window motor
DOWN signal

When DOWN operation

Battery voltage

Other than above

0

6

OR

Passenger power window
UP signal

Main switch passenger switch
UP operation

Battery voltage

Main switch passenger switch
DOWN operation

0

Other than above

0

7

PU

Passenger power window
DOWN signal

Main switch passenger switch
UP operation

0

Main switch passenger switch
DOWN operation

Battery voltage

Other than above

0

8

R/Y

Rear RH power window
UP signal

Main switch rear RH switch
UP operation

Battery voltage

Main switch rear RH switch
DOWN operation

0

Other than above

0

9

OR/B

Rear RH power window
DOWN signal

Main switch rear RH switch
UP operation

0

Main switch rear RH switch
DOWN operation

Battery voltage

Other than above

0

10

G/L

Rear LH power window
UP signal

Main switch rear LH switch
UP operation

Battery voltage

Main switch rear LH switch
DOWN operation

0

Other than above

0

11

L

Rear LH power window
DOWN signal

Main switch rear LH switch
UP operation

0

Main switch rear LH switch
DOWN operation

Battery voltage

Other than above

0

14

W/G

Rear power window relay
ground (RHD models only)

0

Terminal

Wire color

Item

Condition

Voltage (V)

(Approx.)

2

L/W

IGN power supply

Ignition switch (ON or START position)

Battery voltage

4

L/R

G/B

Power window motor
UP signal

When UP operation

Battery voltage

Other than above

0

5

Y/PU

L/Y

O/R

Power window motor
DOWN signal

When DOWN operation

Battery voltage

Other than above

0