Nissan Primera P12. Instruction — part 360
EGR VOLUME CONTROL SYSTEM
EC-625
[YD (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
7.
CHECK EGR VOLUME CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between ECM terminals and EGR volume control valve terminals as follows.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 8.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
8.
CHECK EGR VOLUME CONTROL VALVE
Refer to
EC-625, "Component Inspection"
.
OK or NG
OK
>> GO TO 9.
NG
>> Replace EGR volume control valve.
9.
CHECK INTERMITTENT INCIDENT
Refer to
EC-408, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
>> INSPECTION END
Component Inspection
EBS015CO
EGR VOLUME CONTROL VALVE
With CONSULT-II
1.
Disconnect EGR volume control valve harness connector.
ECM terminal
EGR volume control valve terminal
25
1
26
6
27
3
28
4
Continuity should exist.
MBIB0088E
EC-626
[YD (WITHOUT EURO-OBD)]
EGR VOLUME CONTROL SYSTEM
2.
Check resistance between the following terminals.
●
terminal 2 and terminals 1, 3
●
terminal 5 and terminals 4, 6
If NG, replace EGR volume control valve.
If OK, go to next step.
3.
Remove EGR volume control valve from cylinder head.
(The EGR volume control valve harness connector should
remain connected.)
4.
Reconnect EGR volume control valve harness connector.
5.
Turn ignition switch ON.
6.
Perform “EGR VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that EGR volume control
valve shaft moves smoothly forward and backward according to the valve opening.
If NG, replace the EGR volume control valve.
NOTE:
When installing the EGR volume control valve, make sure that the shaft is in the same position before
checking.
Removal and Installation
EBS015CP
EGR VOLUME CONTROL VALVE
Refer to
EM-23, "EXHAUST MANIFOLD AND TURBOCHARGER"
.
Temperature
°
C (
°
F)
Resistance
Ω
20 (68)
13 - 17
MBIB0007E
SEF819Y
TC BOOST CONTROL SOLENOID VALVE
EC-627
[YD (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
TC BOOST CONTROL SOLENOID VALVE
PFP:14956
Description
EBS015CQ
The load from the turbocharger boost control solenoid valve controls
the actuator. By changing the variable nozzle vane opening through
the rods, the intake air volume is adjusted.
The turbocharger boost control solenoid valve is moved by ON/OFF
pulse from the ECM. The longer the ON pulse, the charge air pres-
sure rises.
ECM Terminals and Reference Value
EBS015CR
Specification data are reference valves, and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may damage the
ECM's transistor. Use a ground other than ECM terminals, such as the ground.
MBIB0626E
MBIB0921E
TER-
MINAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA
(DC Voltage and Pulse Signal)
6
L
Turbocharger boost con-
trol solenoid valve
[Ignition switch ON]
●
Warm-up condition
●
Idle speed
0 - 12.5V
[Ignition switch ON]
●
Warm-up condition
●
Engine speed is 2,000 rpm
0 - 12.5V
MBIB0889E
MBIB0890E
EC-628
[YD (WITHOUT EURO-OBD)]
TC BOOST CONTROL SOLENOID VALVE
Wiring Diagram
EBS015CS
MBWA0616E