Nissan Versa Sedan. Instruction — part 771

STR-26

< DTC/CIRCUIT DIAGNOSIS >

B TERMINAL CIRCUIT

DTC/CIRCUIT DIAGNOSIS

B TERMINAL CIRCUIT

Description

INFOID:0000000009269505

Terminal “B” is constantly supplied with battery power.

Diagnosis Procedure

INFOID:0000000009269506

Regarding Wiring Diagram information, refer to

STR-10, "Wiring Diagram - With Intelligent Key System"

or

STR-15, "Wiring Diagram - Without Intelligent Key System"

.

CAUTION:

Perform diagnosis under the condition that the engine cannot start by the following procedure.

1. Remove fuel pump fuse.

2. Crank or start the engine (where possible) until the fuel pressure is released.

1.

CHECK “B” TERMINAL CIRCUIT

1. Turn ignition switch OFF.

2. Check that starter motor B” terminal connection is clean and tight.

3. Check voltage between starter motor connector F27 and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Check harness between battery and starter motor for open circuit.

2.

CHECK BATTERY CABLE CONNECTION STATUS (VOLTAGE DROP TEST)

1. Shift selector lever to P (Park) or N (Neutral) position.

2. Check voltage between battery positive terminal and starter motor B terminal.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Check harness between the battery and starter motor for continuity.

3.

CHECK GROUND CIRCUIT STATUS (VOLTAGE DROP TEST)

1. Shift selector lever to P (Park) or N (Neutral) position.

2. Check voltage between starter motor case and battery negative terminal.

Is the inspection result normal?

Terminals

Voltage

(Approx.)

(+)

(-)

Starter motor “B” terminal

Terminal

F27

B

Ground

Battery voltage

Terminals

Condition

Voltage

(Approx.)

(+)

(-)

Starter motor

“B“ terminal

Terminal

Battery positive terminal

F27

B

When the ignition switch is in START position

Less than 0.5V

Terminals

Condition

Voltage

(Approx.)

(+)

(-)

Starter motor case

Battery negative terminal

When the ignition switch is in

START position

Less than 0.2V

B TERMINAL CIRCUIT

STR-27

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

A

STR

N

P

O

YES

>> “B” terminal circuit is OK. Further inspection is necessary. Refer to

STR-20, "Work Flow (With

GR8-1200 NI)"

or

STR-24, "Work Flow (Without GR8-1200 NI)"

.

NO

>> Check the starter motor case to engine mounting for high resistance.

STR-28

< DTC/CIRCUIT DIAGNOSIS >

S CONNECTOR CIRCUIT

S CONNECTOR CIRCUIT

Description

INFOID:0000000009269507

The starter motor magnetic switch is supplied with power when the ignition switch is turned to the START posi-

tion while the selector lever is in the P (Park) or N (Neutral) position.

Diagnosis Procedure

INFOID:0000000009269508

Regarding Wiring Diagram information, refer to

STR-10, "Wiring Diagram - With Intelligent Key System"

or

STR-15, "Wiring Diagram - Without Intelligent Key System"

.

CAUTION:

Perform diagnosis under the condition that engine cannot start by the following procedure.

1. Remove fuel pump fuse.

2. Crank or start the engine (where possible) until the fuel pressure is released.

1.

CHECK “S” CONNECTOR CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect starter motor connector.

3. Shift selector lever to “P” (Park) or “N” (Neutral) position.

4. Check voltage between starter motor harness connector F28 and ground.

Is the inspection result normal?

YES

>> “S” circuit is OK. Further inspection is necessary. Refer to

STR-20, "Work Flow (With GR8-1200

NI)"

or

STR-24, "Work Flow (Without GR8-1200 NI)"

.

NO

>> GO TO 2.

2.

CHECK HARNESS CONTINUITY (OPEN CIRCUIT)

1. Disconnect IPDM E/R connector.

2. Check continuity between starter motor harness connector F28 and the IPDM E/R harness connector

E43.

3. Check continuity between starter motor connector F28 terminal S and ground.

Is the inspection result normal?

YES

>> Further inspection is necessary. Refer to

STR-20, "Work Flow (With GR8-1200 NI)"

or

STR-24,

"Work Flow (Without GR8-1200 NI)"

.

NO

>> Repair or replace the harness or connectors.

(+)

(-)

Condition

Voltage

(Approx.)

Connector Terminal

F28

S

Ground

When the ignition switch is in START position

Battery voltage

Starter motor harness connector

IPDM E/R harness connector

Continuity

Connector

Terminal

Connector

Terminal

F28

S

E43

6

Yes

Connector

Terminal

Continuity

F28

S

Ground

No

STARTING SYSTEM

STR-29

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

A

STR

N

P

O

SYMPTOM DIAGNOSIS

STARTING SYSTEM

Symptom Table

INFOID:0000000009269509

Symptom

Reference

No normal cranking

Refer to

STR-20, "Work Flow (With GR8-1200 NI)"

or

STR-24,

"Work Flow (Without GR8-1200 NI)"

.

Starter motor does not rotate