Nissan Versa Sedan. Instruction — part 601

MWI

THE LOW WASHER FLUID WARNING CONTINUES DISPLAYING, OR DOES

NOT DISPLAY

MWI-103

< SYMPTOM DIAGNOSIS >

[TYPE B]

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

THE LOW WASHER FLUID WARNING CONTINUES DISPLAYING, OR
DOES NOT DISPLAY

Description

INFOID:0000000009266554

• The warning is still displayed even after washer fluid is added.

• The warning is not displayed even though the washer tank is empty.

Diagnosis Procedure

INFOID:0000000009266555

1.

CHECK WASHER FLUID LEVEL SWITCH

Perform a unit check for the washer fluid level switch. Refer to

MWI-99, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2

NO

>> Replace washer fluid level switch.Refer to

WW-49, "Exploded View"

.

2.

CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT

Check the washer fluid level switch signal circuit. Refer to

MWI-99, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to

MWI-104, "Removal and Installation"

.

NO

>> Repair or replace harness or connector.

MWI-104

< REMOVAL AND INSTALLATION >

[TYPE B]

COMBINATION METER

REMOVAL AND INSTALLATION

COMBINATION METER

Removal and Installation

INFOID:0000000009266556

REMOVAL

1. Disconnect the negative battery terminal. Refer to

PG-63, "Removal and Installation"

.

2. Remove cluster lid A. Refer to

IP-19, "Removal and Installation"

.

3. Remove the combination meter screws.
4. Pull the combination meter straight out to disengage resin clips.

NOTE:

The illustration shows the clip positions on the back of the com-

bination meter.

5. Disconnect the harness connector from the combination meter and remove.

INSTALLATION

Installation is in the reverse order of removal.

JSNIA3895ZZ

MWI

COMBINATION METER

MWI-105

< UNIT DISASSEMBLY AND ASSEMBLY >

[TYPE B]

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

UNIT DISASSEMBLY AND ASSEMBLY

COMBINATION METER

Exploded View

INFOID:0000000009266557

Disassembly and Assembly

INFOID:0000000009266558

DISASSEMBLY

1. Disengage the pawls of the finisher using a suitable tool and remove the finisher.
2. Remove the screws of the front cover.
3. Disengage the pawls of the front cover using a suitable tool.
4. Pull the front cover straight out to remove from the unified meter control unit.

CAUTION:

• Do not touch the display, pointer, the inside of front cover and the printed area of the dial during

the work.

• Keep away from magnetic sources.

• Do not damage the front cover.

ASSEMBLY

Assembly is in the reverse order of disassembly.

CAUTION:

• Do not touch the display, pointer, the inside of front cover and the printed area of the dial during the

work.

• Keep away from magnetic sources.

• Do not damage the front cover.

1.

Unified meter control unit

2.

Front cover

3.

Finisher

JSNIA3907ZZ