Nissan Versa Sedan. Instruction — part 488
PREPARATION
HAC-7
< PREPARATION >
[MANUAL AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
PREPARATION
PREPARATION
Special Service Tool
INFOID:0000000009269775
The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.
Commercial Service Tool
INFOID:0000000009269776
Tool number
(Kent-Moore No.)
Tool name
Description
—
(J-46534)
Trim Tool Set
Removing trim components
AWJIA0483ZZ
Tool name
Description
Power tool
Loosening nuts, screws and bolts
PIIB1407E
HAC-8
< SYSTEM DESCRIPTION >
[MANUAL AIR CONDITIONING]
COMPONENT PARTS
SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts Location
INFOID:0000000009269777
1.
IPDM E/R
2.
ECM
3.
BCM (view with instrument panel re-
moved)
4.
Front air control
5.
A/C compressor
6.
Front blower motor (view with A/C
unit assembly removed)
7.
Front blower motor resistor (view
with A/C unit assembly removed)
8.
Thermo control amp. (view with A/C
unit assembly removed)
9.
Refrigerant pressure sensor
10. Fuse block (J/B)
11. Blower relay
ALIIA0470ZZ
COMPONENT PARTS
HAC-9
< SYSTEM DESCRIPTION >
[MANUAL AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Component Description
INFOID:0000000009269778
Component
Description
A/C compressor
Vaporized refrigerant is drawn into the A/C compressor from the evaporator, where it is compressed
to a high pressure, high temperature vapor. The hot, compressed vapor is then discharged to the con-
denser.
BCM
The BCM receives the fan ON and A/C ON signals from the front air control and sends a compressor
ON request to the ECM.
ECM
The ECM sends a compressor ON request to the IPDM E/R based on the status of engine operation
and load as well as refrigerant pressure information. If all the conditions are met for A/C operation,
the ECM transmits the compressor ON request to the IPDM E/R.
Fuse Block (J/B)
Located in the passenger compartment, behind the left lower IP, the Fuse Block (J/B) contains the
front blower motor relay and several fuses required for the air conditioner control system.
Front air control
The front air control controls the operation of the A/C and heating system.
Front blower motor
The front blower motor varies the speed at which the air flows through the ventilation system.
Front blower motor relay
The front blower motor relay controls the flow of current to fuse 20, 21 and 22 in the Fuse Block (J/
B). The relay is connected directly to ground, and is energized when the ignition switch is in the ON
or START position.
Front blower motor resistor
Ground for the blower is supplied through blower resistor and the blower speed switch. As the switch
is moved from position 1 through 5, more current is allowed to flow through the motor, for a higher
speed. This is because less resistors are in the path as the switch is moved to a higher position. When
the switch is on the highest position, all resistors are bypassed.
IPDM E/R
A/C relay is integrated in IPDM E/R. IPDM E/R operates A/C relay when receiving A/C compressor
request signal from ECM via CAN communication line.
Refrigerant pressure sensor
EC-26, "Refrigerant Pressure Sensor"
.
Thermo control amp.
Thermo control amp. is composed of thermistor and amplifier. When the A/C switch signal is received
from the front air control, the thermo control amp. transmits the A/C ON signal to the BCM according
to evaporator fin temperature. When the thermistor detecting temperature of the air that passes
through evaporator is extremely low, the thermo control amp. sends the A/C OFF signal to BCM, and
stops the compressor.
HAC-10
< SYSTEM DESCRIPTION >
[MANUAL AIR CONDITIONING]
SYSTEM
SYSTEM
MANUAL AIR CONDITIONING SYSTEM
MANUAL AIR CONDITIONING SYSTEM : System Diagram
INFOID:0000000009269779
MANUAL AIR CONDITIONING SYSTEM : System Description
INFOID:0000000009269780
• The instruction air conditioning system is controlled by a sequence of functions from the front air control, BCM,
ECM, and IPDM E/R.
• The fan speed of the front blower motor is changed by the combination of the fan control dial (fan switch)
operation and blower resistor control.
MANUAL AIR CONDITIONING SYSTEM : Compressor Control
INFOID:0000000009269781
DESCRIPTION
• When A/C switch signal is received from front air control, the thermo control amp. transmits A/C ON signal to
the BCM according to evaporator fin temperature.
• When the front blower motor is operated, the front air control transmits blower fan ON signal to the BCM.
• BCM transmits the A/C ON signal and blower fan ON signal to ECM via CAN communication line. Refer to
EC-39, "CAN COMMUNICATION : System Description"
• ECM judges the conditions of each sensor (Refrigerant pressure sensor signal, accelerator position signal,
etc.), and transmits the A/C compressor request signal to IPDM E/R via CAN communication line.
• By receiving the A/C compressor request signal from ECM, IPDM E/R turns the A/C relay to ON, and acti-
vates the compressor. Refer to
PCS-7, "RELAY CONTROL SYSTEM : System Description"
"RELAY CONTROL SYSTEM : System Description"
ALIIA0477GB
Module/Function
Door control
A/C request signal
Compressor control
Cooling fan control
Front air control
BCM
ECM
IPDM E/R
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.