Nissan Versa Sedan. Instruction — part 306
P0138 HO2S2
EC-223
< DTC/CIRCUIT DIAGNOSIS >
[HR16DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 2 minutes.
5. Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Proceed to
.
NO-1 >> With CONSULT: GO TO 3.
NO-2 >> Without CONSULT: GO TO 5.
3.
PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION B
NOTE:
For better results, perform “DTC WORK SUPPORT” at a temperature of 0 to 30
°C (32 to 86°F).
1. Turn ignition switch ON and select “DATA MONITOR” mode of “ENGINE” using CONSULT.
2. Start engine and warm it up to normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indication is more than 70
°C (158°F).
If not, warm up engine and go to next step when “COOLAN TEMP/S” indication reaches 70
°C (158°F).
7. Open engine hood.
8. Select “HO2S2 (B1) P1146” of “HO2S2” in “DTC WORK SUPPORT” mode of “ENGINE” using CONSULT.
9. Follow the instruction of CONSULT.
NOTE:
It will take at most 10 minutes until “COMPLETED” is displayed.
10. Touch “SELF-DIAG RESULT”.
Which is displayed on CONSULT
OK
>> INSPECTION END
NG
>> Proceed to
.
CAN NOT BE DIAGNOSED>>GO TO 4.
4.
PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION B AGAIN
1. Turn ignition switch OFF and leave the vehicle in a cool place (soak the vehicle).
2. Perform DTC confirmation procedure again.
>> GO TO 3.
5.
PERFORM COMPONENT FUNCTION CHECK FOR MALFUNCTION B
Perform component function check. Refer to
EC-223, "Component Function Check"
.
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Proceed to
.
Component Function Check
INFOID:0000000009620482
1.
PERFORM COMPONENT FUNCTION CHECK-I
Without CONSULT
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Restart engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no
load.
4. Let engine idle for 1 minute.
5. Check the voltage between ECM harness connector terminals under the following condition.
EC-224
< DTC/CIRCUIT DIAGNOSIS >
[HR16DE]
P0138 HO2S2
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
PERFORM COMPONENT FUNCTION CHECK-II
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 3.
3.
PERFORM COMPONENT FUNCTION CHECK-III
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Go to
Diagnosis Procedure
INFOID:0000000009267122
1.
INSPECTION START
Confirm the detected malfunction (A or B). Refer to
.
Which malfunction is detected?
A
>> GO TO 2.
B
>> GO TO 9.
2.
CHECK GROUND CONNECTION
1. Turn ignition switch OFF.
2. Check ground connection E15. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace ground connection.
3.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect heated oxygen sensor 2 harness connector.
2. Disconnect ECM harness connector.
3. Check the continuity between HO2S2 harness connector and ECM harness connector.
ECM
Condition
Voltage
Connector
+
–
Terminal
Terminal
F11
50
(HO2S2)
59
Revving up to 4,000 rpm under no load at least 10 times
The voltage should be above 0.68 V
at least once during this procedure.
ECM
Condition
Voltage
Connector
+
–
Terminal
Terminal
F11
50
(HO2S2)
59
Keeping engine at idle for 10 minutes
The voltage should be above 0.68 V
at least once during this procedure.
ECM
Condition
Voltage
Connector
+
–
Terminal
Terminal
F11
50
(HO2S2)
59
Coasting from 80 km/h (50 MPH) in D position (A/T or
CVT), 4th gear position (M/T)
The voltage should be above 0.68 V
at least once during this procedure.
P0138 HO2S2
EC-225
< DTC/CIRCUIT DIAGNOSIS >
[HR16DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
4.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check the continuity between HO2S2 harness connector and ECM harness connector.
2. Check the continuity between HO2S2 harness connector and ground or ECM harness connector and
ground.
3. Also check harness for short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
5.
CHECK HO2S2 CONNECTOR FOR WATER
Check connectors for water.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace harness or connectors.
6.
CHECK HEATED OXYGEN SENSOR 2
EC-227, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> GO TO 7.
7.
REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to
CAUTION:
• Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
• Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved anti-seize lubricant (com-
mercial service tool).
HO2S2
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
1
F11
59
Existed
HO2S2
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
4
F11
50
Existed
HO2S2
Ground
Continuity
Connector
Terminal
E63
4
Ground
Not existed
ECM
Ground
Continuity
Connector
Terminal
F11
50
Ground
Not existed
Water should not exist.
EC-226
< DTC/CIRCUIT DIAGNOSIS >
[HR16DE]
P0138 HO2S2
>> INSPECTION END
8.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
>> INSPECTION END
9.
CHECK GROUND CONNECTION
1. Turn ignition switch OFF.
2. Check ground connection E15. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> Repair or replace ground connection.
10.
CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
1. Clear the mixture ratio self-learning value. Refer to
.
2. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected? Is it difficult to start engine?
YES
>> Perform trouble diagnosis for DTC P0172. Refer to
.
NO
>> GO TO 11.
11.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Disconnect ECM harness connector.
4. Check the continuity between HO2S2 harness connector and ECM harness connector.
5. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 12.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
12.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check the continuity between HO2S2 harness connector and ECM harness connector.
2. Check the continuity between HO2S2 harness connector or ECM harness connector and ground.
3. Also check harness for short to power.
HO2S2
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
1
F11
59
Existed
HO2S2
ECM
Continuity
Connector
Terminal
Connector
Terminal
E63
4
F11
50
Existed
HO2S2
Ground
Continuity
Connector
Terminal
E63
4
Ground
Not existed
ECM
Ground
Continuity
Connector
Terminal
F11
50
Ground
Not existed